Selective non-enzymatic total bilirubin detection in serum using europium complexes with different β-diketone-derived ligands as luminescence probes

被引:0
|
作者
Wei Yang
Jinfeng Xia
Guohong Zhou
Danyu Jiang
Qiang Li
Shiwei Wang
Xiaohong Zheng
Xi Li
Yibo Shen
Xin Li
机构
[1] East China Normal University,Department of Chemistry
[2] Chinese Academy of Sciences,Shanghai Institute of Ceramics
来源
Analytical and Bioanalytical Chemistry | 2018年 / 410卷
关键词
Total bilirubin; Europium(III) complex; Biosensor; Fluorescence quenching; σ-hole;
D O I
暂无
中图分类号
学科分类号
摘要
Three europium(III) complexes, Eu(ectfd)3 (Hectfd = 1-(9-ethyl-9H-carbazol-7-yl)-4,4,4-trifluorobutane-1,3-dione), Eu(tta)3 (Htta = 4,4,4-trifluoro-1-(thiophen-2-yl)-butane-1,3-dione), and Eu(dbt)3 (Hdbt = 2-(4',4',4'-trifluoro-1',3'-dioxobutyl)dibenzothiophene), were synthesized and employed to detect total bilirubin (BR) in blood-serum samples. UV-visible absorption and fluorescence (FL) spectroscopies were used to evaluate the selectivity of each europium (III) fluorescence probe to BR, which was shown to remarkably reduce the luminescence intensities of the europium(III) complexes at a wavelength of 612 nm. The luminescence intensity of each complex is linearly related to BR concentration. Eu(tta)3 was shown to be the more-appropriate fluorescence probe for the sensitive and reliable detection of total BR in blood serum samples than either Eu(ectfd)3 or Eu(dbt)3. This observation can be ascribed to special σ-hole bonding between Htta and BR. In addition, the optimal pH test conditions for the detection of BR in human serum by the Eu(tta)3 probe were determined. Sensitivity was shown to be dramatically affected by the pH of the medium. The experimental results reveal that pH 7.5 is optimal for this probe, which coincides with the pH of human serum. Furthermore, BR detection using the Eu(tta)3 luminescence probe is simple, practical, and relatively free of interference from coexisting substances; it has a minimum detection limit (DL) of 68 nM and is a potential candidate for the routine assessment of total BR in serum samples.
引用
收藏
页码:6459 / 6468
页数:9
相关论文
共 1 条
  • [1] Selective non-enzymatic total bilirubin detection in serum using europium complexes with different β-diketone-derived ligands as luminescence probes
    Yang, Wei
    Xia, Jinfeng
    Zhou, Guohong
    Jiang, Danyu
    Li, Qiang
    Wang, Shiwei
    Zheng, Xiaohong
    Li, Xi
    Shen, Yibo
    Li, Xin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (25) : 6459 - 6468