A sensitive mercury (II) sensor based on CuO nanoshuttles/poly(thionine) modified glassy carbon electrode

被引:3
|
作者
Zhaojing Yin
Jiajia Wu
Zhousheng Yang
机构
[1] Anhui Normal University,Anhui Key Laboratory of chemo
来源
Microchimica Acta | 2010年 / 170卷
关键词
CuO nanoshuttle; Hg; Poly(thionine); Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Shuttle-like copper oxide (CuO) was prepared by a hydrothermal decomposition process. The resulting material was characterized by scanning electron microscopy and X-ray diffraction. It was then immobilized on the surface of a glassy carbon electrode modified with a film of poly(thionine). A pair of well-defined and reversible redox peaks for Hg(II) was observed with the resulting electrode in pH 7.0 solutions. The anodic and cathodic peak potentials occurred at 0.260 V and 0.220 V (vs. Ag/AgCl), respectively. The modified electrode displayed excellent amperometric response to Hg(II), with a linear range from 40 nM to 5.0 mM and a detection limit of 8.5 nM at a signal-to-noise ratio of 3. The sensor exhibited high selectivity and reproducibility and was successfully applied to the determination of Hg(II) in water samples.
引用
收藏
页码:307 / 312
页数:5
相关论文
共 50 条
  • [31] A sensitive sensor for determination of l-tryptophan based on gold nanoparticles/poly(alizarin red S)-modified glassy carbon electrode
    Honghui Liu
    Yanling Chen
    Yunchun Liu
    Zhousheng Yang
    Journal of Solid State Electrochemistry, 2013, 17 : 2623 - 2631
  • [32] A sensitive and selective nitrite sensor based on a glassy carbon electrode modified with gold nanoparticles and sulfonated graphene
    Su-Juan Li
    Guo-Yan Zhao
    Rong-Xia Zhang
    Ya-Li Hou
    Lin Liu
    Huan Pang
    Microchimica Acta, 2013, 180 : 821 - 827
  • [33] A sensitive and selective nitrite sensor based on a glassy carbon electrode modified with gold nanoparticles and sulfonated graphene
    Li, Su-Juan
    Zhao, Guo-Yan
    Zhang, Rong-Xia
    Hou, Ya-Li
    Liu, Lin
    Pang, Huan
    MICROCHIMICA ACTA, 2013, 180 (9-10) : 821 - 827
  • [34] A sensitive voltammetric sensor for taxifolin based on graphene nanosheets with certain orientation modified glassy carbon electrode
    Wang, Fei
    Wu, Yanju
    Lu, Kui
    Ye, Baoxian
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 188 - 194
  • [35] A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode
    Jiang, Liao-Chuan
    Zhang, Wei-De
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1402 - 1407
  • [36] Highly sensitive and simultaneous electrochemical determination of lead and cadmium ions by poly(thionine)/MWCNTs-modified glassy carbon electrode in the presence of bismuth ions
    Seifi, Afsaneh
    Afkhami, Abbas
    Madrakian, Tayyebeh
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2022, 52 (10) : 1513 - 1523
  • [37] Nonenzymatic glucose sensor based on nickel(II)oxide/ordered mesoporous carbon modified glassy carbon electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Ding, Yaping
    Zhang, Zhao
    Deng, Dongmei
    Lu, Bo
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 102 : 307 - 311
  • [38] Highly sensitive and simultaneous electrochemical determination of lead and cadmium ions by poly(thionine)/MWCNTs-modified glassy carbon electrode in the presence of bismuth ions
    Afsaneh Seifi
    Abbas Afkhami
    Tayyebeh Madrakian
    Journal of Applied Electrochemistry, 2022, 52 : 1513 - 1523
  • [39] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang, Yang
    Fu, Renzhong
    Yuan, Jianjun
    Wu, Shiyuan
    Zhang, Jialiang
    Wang, Haiying
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2241 - 2249
  • [40] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang Yang
    Renzhong Fu
    Jianjun Yuan
    Shiyuan Wu
    Jialiang Zhang
    Haiying Wang
    Microchimica Acta, 2015, 182 : 2241 - 2249