A sensitive mercury (II) sensor based on CuO nanoshuttles/poly(thionine) modified glassy carbon electrode

被引:3
|
作者
Zhaojing Yin
Jiajia Wu
Zhousheng Yang
机构
[1] Anhui Normal University,Anhui Key Laboratory of chemo
来源
Microchimica Acta | 2010年 / 170卷
关键词
CuO nanoshuttle; Hg; Poly(thionine); Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Shuttle-like copper oxide (CuO) was prepared by a hydrothermal decomposition process. The resulting material was characterized by scanning electron microscopy and X-ray diffraction. It was then immobilized on the surface of a glassy carbon electrode modified with a film of poly(thionine). A pair of well-defined and reversible redox peaks for Hg(II) was observed with the resulting electrode in pH 7.0 solutions. The anodic and cathodic peak potentials occurred at 0.260 V and 0.220 V (vs. Ag/AgCl), respectively. The modified electrode displayed excellent amperometric response to Hg(II), with a linear range from 40 nM to 5.0 mM and a detection limit of 8.5 nM at a signal-to-noise ratio of 3. The sensor exhibited high selectivity and reproducibility and was successfully applied to the determination of Hg(II) in water samples.
引用
收藏
页码:307 / 312
页数:5
相关论文
共 50 条
  • [1] A sensitive mercury (II) sensor based on CuO nanoshuttles/poly(thionine) modified glassy carbon electrode
    Yin, Zhaojing
    Wu, Jiajia
    Yang, Zhousheng
    MICROCHIMICA ACTA, 2010, 170 (3-4) : 307 - 312
  • [2] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Huo, Hong Yu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 195 - 199
  • [3] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Hong Yu Huo
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2009, 167 : 195 - 199
  • [4] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [5] Reagentless alcohol sensor based on thionine-TDI modified glassy carbon electrode
    Yu, Ai-Min
    Han, Ji-Lin
    Yang, Ke-Sheng
    Chen, Hong-Yuan
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1995, 16 (08):
  • [6] Non-enzymatic hydrogen peroxide sensor based on palladium-decorated poly(thionine) modified glassy carbon electrode
    Celebi, Mutlu Sonmez
    Kara, Songul Kirlak
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2024, 71 (05) : 482 - 492
  • [7] A REAGENTLESS ALCOHOL SENSOR-BASED ON THIONINE-TDI MODIFIED GLASSY-CARBON ELECTRODE
    YU, AM
    HAN, JL
    YANG, KS
    CHEN, HY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (08): : 1204 - 1206
  • [8] Amperometric NADH Biosensor Based on Magnetic Chitosan Microspheres/Poly(thionine) Modified Glassy Carbon Electrode
    Liu, Ya
    Zhang, Hai-Li
    Lai, Guo-Song
    Yu, Ai-Min
    Huang, Yu-Mei
    Han, De-Yan
    ELECTROANALYSIS, 2010, 22 (15) : 1725 - 1732
  • [9] Characteristics of a Poly(thionine) Modified Glassy Carbon Electrode and the Detection of Dopamine and Uric acid
    Ahammad, A. J. Saleh
    Li, Xiao-bo
    Rahman, Md. Mahbubur
    Noh, Kwang-Mo
    Lee, Jae-Joon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (06): : 7806 - 7815
  • [10] Simultaneous Determination of Ranitidine and Metronidazole at Poly(thionine) Modified Anodized Glassy Carbon Electrode
    Rahman, Md. Mahbubur
    Li, Xiao-bo
    Jeon, Young-Deok
    Lee, Ho-Joon
    Lee, Soo Jae
    Lee, Jae-Joon
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2012, 3 (02) : 90 - 94