Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system

被引:0
|
作者
Andreas Steven Kunz
Theresa Sophie Patzer
Jan-Peter Grunz
Karsten Sebastian Luetkens
Viktor Hartung
Robin Hendel
Tabea Fieber
Franca Genest
Süleyman Ergün
Thorsten Alexander Bley
Henner Huflage
机构
[1] University Hospital Würzburg,Department of Diagnostic and Interventional Radiology
[2] University Hospital Würzburg,Department of Trauma, Hand, Plastic and Reconstructive Surgery
[3] Julius-Maximilians-Universität Würzburg,Orthopedic Clinic König
[4] University of Würzburg,Ludwig
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been shown to be a powerful tool for 3D imaging of the appendicular skeleton, allowing for detailed visualization of bone microarchitecture. This study was designed to compare artifacts in the presence of osteosynthetic implants between CBCT and multidetector computed tomography (MDCT) in cadaveric wrist scans. A total of 32 scan protocols with varying tube potential and current were employed: both conventional CBCT and MDCT studies were included with tube voltage ranging from 60 to 140 kVp as well as additional MDCT protocols with dedicated spectral shaping via tin prefiltration. Irrespective of scanner type, all examinations were conducted in ultra-high-resolution (UHR) scan mode. For reconstruction of UHR-CBCT scans an additional iterative metal artifact reduction algorithm was employed, an image correction tool which cannot be used in combination with UHR-MDCT. To compare applied radiation doses between both scanners, the volume computed tomography dose index for a 16 cm phantom (CTDIvol) was evaluated. Images were assessed regarding subjective and objective image quality. Without automatic tube current modulation or tube potential control, radiation doses ranged between 1.3 mGy (with 70 kVp and 50.0 effective mAs) and 75.2 mGy (with 140 kVp and 383.0 effective mAs) in UHR-MDCT. Using the pulsed image acquisition method of the CBCT scanner, CTDIvol ranged between 2.3 mGy (with 60 kVp and 0.6 mean mAs per pulse) and 61.0 mGy (with 133 kVp and 2.5 mean mAs per pulse). In essence, all UHR-CBCT protocols employing a tube potential of 80 kVp or more were found to provide superior overall image quality and artifact reduction compared to UHR-MDCT (all p < .050). Interrater reliability of seven radiologists regarding image quality was substantial for tissue assessment and moderate for artifact assessment with Fleiss kappa of 0.652 (95% confidence interval 0.618–0.686; p < 0.001) and 0.570 (95% confidence interval 0.535–0.606; p < 0.001), respectively. Our results demonstrate that the UHR-CBCT scan mode of a twin robotic X-ray system facilitates excellent visualization of the appendicular skeleton in the presence of metal implants. Achievable image quality and artifact reduction are superior to dose-comparable UHR-MDCT and even MDCT protocols employing spectral shaping with tin prefiltration do not achieve the same level of artifact reduction in adjacent soft tissue.
引用
收藏
相关论文
共 50 条
  • [31] High-fidelity artifact correction for cone-beam CT imaging of the brain
    Sisniega, A.
    Zbijewski, W.
    Xu, J.
    Dang, H.
    Stayman, J. W.
    Yorkston, J.
    Aygun, N.
    Koliatsos, V.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1415 - 1439
  • [32] Cone-beam X-ray tomographic and stereo-imaging
    Wang, Ge
    Zhao, Shiying
    Cheng, Ping-Chin
    1996, Center for Biomedical Engineering, NTU College of Medicine, Taipei, Taiwan (08):
  • [33] Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
    Hattori, Haruki
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)
  • [34] 3D cone-beam CT of the ankle using a novel twin robotic X-ray system: Assessment of image quality and radiation dose
    Grunz, Jan-Peter
    Kunz, Andreas Steven
    Gietzen, Carsten Herbert
    Weng, Andreas Max
    Veyhl-Wichmann, Maike
    Ergun, Suleyman
    Schmitt, Rainer
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 119
  • [35] Twin robotic x-ray system in small bone and joint trauma: impact of cone-beam computed tomography on treatment decisions
    Jan-Peter Grunz
    Lenhard Pennig
    Tabea Fieber
    Carsten Herbert Gietzen
    Julius Frederik Heidenreich
    Henner Huflage
    Philipp Gruschwitz
    Philipp Josef Kuhl
    Bernhard Petritsch
    Aleksander Kosmala
    Thorsten Alexander Bley
    Tobias Gassenmaier
    European Radiology, 2021, 31 : 3600 - 3609
  • [36] Twin robotic x-ray system in small bone and joint trauma: impact of cone-beam computed tomography on treatment decisions
    Grunz, Jan-Peter
    Pennig, Lenhard
    Fieber, Tabea
    Gietzen, Carsten Herbert
    Heidenreich, Julius Frederik
    Huflage, Henner
    Gruschwitz, Philipp
    Kuhl, Philipp Josef
    Petritsch, Bernhard
    Kosmala, Aleksander
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 3600 - 3609
  • [37] High spatial resolution 3D X-ray cone-beam microtomography
    Engelke, K
    Karolczak, M
    Lutz, A
    Seibert, U
    Schaller, S
    Kalender, WA
    RADIOLOGY, 1999, 213P : 194 - 194
  • [38] CLIMAR: classified linear interpolation based metal artifact reduction for severe metal artifact reduction in x-ray CT imaging
    Yoon, Huisu
    Lee, Kyoung-Yong
    Bechwati, Ibrahim
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [39] Comparison of fan- and cone-beam imaging capabilities on a portable x-ray imaging system
    White, TA
    Roney, T
    Pink, RJ
    Noo, F
    Clackdoyle, R
    Smith, M
    Jones, WF
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 138 - 146
  • [40] A new cone-beam X-ray CT system with a reduced size planar detector
    Li Liang
    Chen Zhi-Qiang
    Zhang Li
    Xing Yu-Xiang
    Kang Ke-Jun
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (08): : 812 - 817