Novel Bioresorbable Stent Design and Fabrication: Congenital Heart Disease Applications

被引:13
|
作者
Welch T.R. [1 ]
Eberhart R.C. [3 ]
Reddy S.V. [2 ]
Wang J. [1 ]
Nugent A. [2 ]
Forbess J. [1 ]
机构
[1] Division of Pediatric Cardiothoracic Surgery, Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX
[2] Division of Cardiology, Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, TX
[3] Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
关键词
Bioresorbable polymer; Pediatrics; PLLA stent; Thermal treatment;
D O I
10.1007/s13239-013-0136-8
中图分类号
学科分类号
摘要
The design and development of bioresorbable stents tailored for treatment of pediatric patients with congenital heart disease is described. First, we examined the mechanical properties of thermally annealed PL-32 and PL-18 PLLA fibers using an Instron 5565 tensiometer. Stent designs ranging from 3 to 6 mm diameter and up to 15 mm length were examined. We adapted a winding jig to enable fabrication of coiled stents consisting of double-opposed helices. Double-opposed helical stents were thermally annealed for strength and flexibility. Following winding, stents were crimped on appropriately sized balloon catheters, and then expanded in a 37 °C water bath. Mechanical characteristics were measured as a function of stent size and design. PL-32 fiber has stronger mechanical properties with a 33% increase in stiffness. The opposing coil design improves stent expansion for larger stent designs. In addition, the stiffness of small diameter double-opposed helical stents was higher than values for the larger diameter stents hence having higher collapse pressure 1. 07 ± 0. 02 atm and the resistance to external pressure-induced collapse for larger diameter stents was lower decreasing to 0. 63 ± 0. 02 atm. The larger deformations at larger diameters were experienced since mechanical strain in the stent fibers is increased under these conditions. This led to increased twisting of the coils and higher striation angle measurements ranging from 17. 5° to 26. 7° from smaller to larger stents. The large diameter double opposed helix stents showed larger axial shortening of 3-3. 5% and higher elastic recoil increase of 1. 12%. The PL-32 stents also showed a slower degradation of 5% over 6 months. Modulating the number of coils within the double helical stent design and winding in opposing directions favorably affects stent mechanical properties. © 2013 Biomedical Engineering Society.
引用
收藏
页码:171 / 182
页数:11
相关论文
共 50 条
  • [21] CONGENITAL HEART-DISEASE - APPLICATIONS AND LIMITATIONS
    MEYER, RA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (06): : 719 - 719
  • [22] Graph theory applications in congenital heart disease
    Lee, Yao-Ting
    Chen, Shyh-Jye
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [23] Graph theory applications in congenital heart disease
    Yao-Ting Lee
    Shyh-Jye Chen
    Scientific Reports, 13
  • [24] Novel therapeutic strategies in congenital heart disease
    Gilyarevsky, SR
    KARDIOLOGIYA, 1997, 37 (10) : 88 - 99
  • [25] Expandable bioresorbable endovascular stent. I. Fabrication and properties
    Su, SH
    Chao, RYN
    Landau, CL
    Nelson, KD
    Timmons, RB
    Meidell, RS
    Eberhart, RC
    ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (06) : 667 - 677
  • [26] Bioresorbable Stent Restenosis: New Devices, Novel Situations
    Nunez-Gil, Ivan J.
    Echavarria, Mauro
    Escaned, Javier
    Biagioni, Corina
    Feltes, Gisela
    Fernandez-Ortiz, Antonio
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (12): : E164 - E166
  • [27] Expandable Bioresorbable Endovascular Stent. I. Fabrication and Properties
    Shih-Horng Su
    Robert Y. N. Chao
    Charles L. Landau
    Kevin D. Nelson
    Richard B. Timmons
    Robert S. Meidell
    Robert C. Eberhart
    Annals of Biomedical Engineering, 2003, 31 : 667 - 677
  • [28] Development of a new intravascular stent (Genesis stent) for use in infants and children with congenital heart disease
    Forbes, TJ
    Rodriguez-Cruz, E
    Webster, P
    Amin, Z
    Benson, L
    Fagan, T
    Hellenbrand, W
    Latson, L
    Moore, P
    Vincent, J
    Mullins, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 404A - 404A
  • [29] Hybrid Intraoperative Pulmonary Artery Stent Placement for Congenital Heart Disease
    Menon, Shaji C.
    Cetta, Frank
    Dearani, Joseph A.
    Burkhart, Harold A.
    Cabalka, Allison K.
    Hagler, Donald J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (12): : 1737 - 1741
  • [30] Flow characteristics predict in-stent restenosis in congenital heart disease
    Paolillo, JA
    Kreutzer, J
    Clark, BJ
    Rome, JJ