Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide

被引:0
|
作者
Ab Rahman Marlinda
Alagarsamy Pandikumar
Subramaniam Jayabal
Norazriena Yusoff
Abu Bakar Suriani
Nay Ming Huang
机构
[1] University of Malaya,Low Dimensional Materials Research Centre, Department of Physics, Faculty of Science
[2] SRM University,Research Institute & Department of Chemistry
[3] University Pendidikan Sultan Idris,Nanotechnology Research Centre, Faculty of Science and Mathematics
来源
Microchimica Acta | 2016年 / 183卷
关键词
Electroanalysis; Biosensor; Nanocomposite; Localized surface plasmon resonance; LSPR; Linear sweep voltammetry; X-ray diffractometry; X-ray photoelectron spectroscopy; Capillary dilatator;
D O I
暂无
中图分类号
学科分类号
摘要
Myoglobin-modified gold nanorods incorporating reduced graphene oxide (rGO) were fabricated and deposited on a glassy carbon electrode (GCE) to obtain a sensor for nitric oxide (NO). The Mb-AuNR/rGO nanohybrid showed a transverse localized surface plasmon resonance (LSPR) band with a peak at 508 nm, and a longitudinal LSPR band at 724 nm. The AuNRs have an average length of 38 ± 3 nm and a width of 11 ± 1 nm. The GCE modified with the nanohybrid is shown to be a viable sensor for the determination of NO by linear sweep voltammetry. Its electrocatalytic response toward the oxidation of NO is distinctly enhanced compared to other electrodes. The sensor, best operated at a working voltage of 0.85 V (vs. SCE), showed two linear response ranges (from 10 to100 μM, and from 100 to 1000 μM), with a detection limit of 5.5 μM. Furthermore, it exhibits excellent selectivity for NO over common interferents such as NaNO3, and also over electroactive species such as ascorbate, dopamine, glucose, and uric acid. These properties make it a promising tool for the detection of NO in situations such as capillary and pulmonary hypertension and embolism, and during vasodilation.
引用
收藏
页码:3077 / 3085
页数:8
相关论文
共 50 条
  • [41] Reduced graphene oxide/gold nanoparticles nanocomposite-modified glassy carbon electrode for determination of endocrine disruptor methylparaben
    Piovesan, Jamille V.
    Santana, Edson R.
    Spinelli, Almir
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 813 : 163 - 170
  • [42] Sensitive and selective stripping voltammetric determination of copper(II) using a glassy carbon electrode modified with amino-reduced graphene oxide and β-cyclodextrin
    Huang, Shan
    Lu, Shuangyan
    Huang, Chusheng
    Sheng, Jiarong
    Su, Wei
    Zhang, Lixia
    Xiao, Qi
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2529 - 2539
  • [43] Electroanalytical Determination of Ziram by Differential Pulse Voltammetry with Reduced Graphene Oxide/Gold Nanoparticles Modified Glassy Carbon Electrode
    Aslan, Nazife
    Ocak, Sema Bilge
    Gokmen, Ugur
    ACTA CHIMICA SLOVENICA, 2022, 69 (03) : 638 - 646
  • [44] Voltammetric Determination of Folic Acid Using Adsorption of Methylene Blue onto Electrodeposited of Reduced Graphene Oxide Film Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Weina
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (02) : 312 - 319
  • [45] Electrochemical detection of selenium using glassy carbon electrode modified with reduced graphene oxide
    Idris, Azeez O.
    Mabuba, Nonhlangabezo
    Nkosi, Duduzile
    Maxakato, Nobanathi
    Arotiba, Omotayo A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (06) : 534 - 547
  • [46] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Dai, Hongxiu
    Wang, Nan
    Wang, Donglei
    Zhang, Xiaomei
    Ma, Houyi
    Lin, Meng
    MICROCHIMICA ACTA, 2016, 183 (11) : 3053 - 3059
  • [47] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Hongxiu Dai
    Nan Wang
    Donglei Wang
    Xiaomei Zhang
    Houyi Ma
    Meng Lin
    Microchimica Acta, 2016, 183 : 3053 - 3059
  • [48] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Nadia Ait Ahmed
    Houa Hammache
    Marielle Eyraud
    Carine Chassigneux
    Florence Vacandio
    Philippe Knauth
    Laid Makhloufi
    Nour-eddine Gabouze
    Journal of the Iranian Chemical Society, 2019, 16 : 1957 - 1963
  • [49] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Ahmed, Nadia Ait
    Hammache, Houa
    Eyraud, Marielle
    Chassigneux, Carine
    Vacandio, Florence
    Knauth, Philippe
    Makhloufi, Laid
    Gabouze, Nour-eddine
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (09) : 1957 - 1963
  • [50] Amperometric Determination of Sulfide by Glassy Carbon Electrode Modified with Hemin Functionalized Reduced Graphene Oxide
    Cao, Xiaodong
    Gao, Jiaona
    Ye, Yingwang
    Wang, Pengfei
    Ding, Shun
    Ye, Yongkang
    Sun, Hanju
    ELECTROANALYSIS, 2016, 28 (01) : 140 - 144