Theoretical thermal analysis of heat recovery by two phase closed Thermosyphon from engine exhaust

被引:0
|
作者
Yogita Umesh Yerne
Siddappa Sharanappa Bhusnoor
机构
[1] K.J.Somaiya College of Engineering,Department of Mechanical Engineering
来源
Heat and Mass Transfer | 2019年 / 55卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Due to the increase in energy requirements for various process industries and depletion of fossil fuel reservoirs, it is necessary to recover the heat energy which is exhausted to the environment from different sources. Effective utilization and recovery of waste heat is of great importance for the preservation of energy sources and protection of an environment and health hazards. For many industrial practices because of high effectiveness the application of Thermosyphon is increasing for the recovery of waste heat. The focus of the present study is to investigate theoretically the performance parameters (thermal and geometrical) of the Single tube wickless heat pipe heat exchanger (Thermosyphon) for heat recovery at simulated diesel engine exhaust conditions (Air temperature of ~150, 250 and 350 °C and under forced convective heating and cooling at different Reynolds number). From the theoretical analysis it was observed that effectiveness of Thermosyphon was over 50% for each of the conditions and it was increased up to 88% with decreasing inlet hot air velocity down to 1 m/s at temperature of 350 °C. It was also observed that at equal heat capacity rate of hot and cold fluids the effectiveness is minimum.
引用
收藏
页码:3211 / 3221
页数:10
相关论文
共 50 条
  • [41] Numerical Study on the Transient Thermal Performance of a Two-Phase Closed Thermosyphon
    Zhao, Zhongchao
    Zhang, Yong
    Zhang, Yanrui
    Zhou, Yimeng
    Hu, Hao
    ENERGIES, 2018, 11 (06):
  • [42] Energetic efficiency analysis on two-phase closed thermosyphon heat exchangers for performance enhancement of dehumidification
    Wu, XP
    Johnson, P
    Akbarzadeh, A
    RENEWABLE ENERGY: TECHNOLOGIES & POLICIES FOR SUSTAINABLE DEVELOPMENT, 1999, : 517 - 522
  • [43] Thermal characteristics of a resurfaced condenser and evaporator closed two-phase thermosyphon
    Rahimi, Masoud
    Asgary, Kayvan
    Jesri, Simin
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (06) : 703 - 710
  • [44] Investigation of Engine Exhaust Heat Recovery Systems Utilizing Thermal Battery Technology
    Zhu, Bo
    Zhang, Yi
    Wang, Dengping
    WORLD ELECTRIC VEHICLE JOURNAL, 2024, 15 (10):
  • [45] Exergetic analysis of a long two-phase closed thermosyphon system
    Ziapour, Behrooz M.
    Shaker, Hadi
    INTERNATIONAL JOURNAL OF EXERGY, 2010, 7 (06) : 714 - 730
  • [46] INFLUENCE OF VAPOR BUBBLES ON THE THERMAL PERFORMANCE OF A TWO-PHASE CLOSED THERMOSYPHON LOOP WITH A LIQUID HEAT TRANSFER AGENT
    Wei, Lingjiao
    Yuan, Dazhong
    Guo, Chaohong
    Tang, Dawei
    HEAT TRANSFER RESEARCH, 2016, 47 (12) : 1109 - 1120
  • [47] Computational Models Analysis of Diesel Engine Exhaust Waste Heat Recovery
    Hou Xuejun
    Xiao Peng
    2012 INTERNATIONAL CONFERENCE ON ECOLOGY, WASTE RECYCLING, AND ENVIRONMENT (ICEWE 2012), 2012, 7 : 228 - 233
  • [48] Closed-Loop PI Control of an Organic Rankine Cycle for Engine Exhaust Heat Recovery
    Zhang, Wen
    Wang, Enhua
    Meng, Fanxiao
    Zhang, Fujun
    Zhao, Changlu
    ENERGIES, 2020, 13 (15)
  • [49] Numerical analysis of influence of heat load on temperature of battery surface with cooling by a two-phase closed thermosyphon
    Krasnoshlykov, Alexander
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES (TBET-2016), 2016, 92
  • [50] Heat transfer characteristics of a two-phase closed thermosyphon to the fill charge ratio
    Park, YJ
    Kang, HK
    Kim, CJ
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (23) : 4655 - 4661