Automated in situ trace element analysis of silicate materials by laser ablation inductively coupled plasma mass spectrometry

被引:0
|
作者
Zhongxing Chen
Dante Canil
Henry P. Longerich
机构
[1] School of Earth and Ocean Sciences,
[2] University of Victoria,undefined
[3] PO Box 3055,undefined
[4] Victoria,undefined
[5] BC Canada V8W 3P6 e-mail: Zhongxing.Chen@usm.edu,undefined
[6] Department of Earth Sciences and Centre for Earth Resources Research,undefined
[7] Memorial University of Newfoundland,undefined
[8] St. John’s,undefined
[9] Newfoundland,undefined
[10] Canada A1B 3X5,undefined
关键词
Inductively Couple Plasma Mass Spectrometry; Laser Ablation; External Calibration; Trace Element Analysis; Transport Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes the automated in situ trace element analysis of solid materials by laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS). A compact computer-controlled solid state Nd:YAG MerchantekTM EO UV laser ablation (LA) system has been coupled with the high sensitivity VG PQII S ICP-MS. A two-directional communication was interfaced in-house between the ICP-MS and the LA via serial RS-232 port. Each LA-ICP-MS analysis at a defined point includes a 60 s pre-ablation delay, a 60 s ablation, and a 90 s flush delay. The execution of each defined time setting by LA was corresponding to the ICP-MS data acquisition allowing samples to be run in automated cycle sequences like solution auto-sampler ICP-MS analysis. Each analytical cycle consists of four standards, one control reference material, and 15 samples, and requires about 70 min. Data produced by Time Resolved Analysis (TRA) from ICP-MS were later reduced off-line by in-house written software. Twenty-two trace elements from four reference materials (NIST SRM 613, and fused glass chips of BCR-2, SY-4, and G-2) were determined by the automated LA-ICP-MS method. NIST SRM 610 or NIST SRM 613 was used as an external calibration standard, and Ca as an internal standard to correct for drift, differences in transport efficiency and sampling yield. Except for Zr and Hf in G-2, relative standard deviations for all other elements are less than 10%. Results compare well with the data reported from literature with average limits of detection from 1 ng g–1 to 455 ng g–1 and less than 100 ng g–1 for most trace elements.
引用
收藏
页码:73 / 78
页数:5
相关论文
共 50 条
  • [41] Quantitative Analysis of Trace Elements in Silicon Carbide Device by Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Zhou Hui
    Wang Zheng
    Zhu Yan
    Li Qing
    Chen Yi-Rui
    Qu Hai-Yun
    Zou Hui-Jun
    Du Yi-Ping
    Hu Hui-Lian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (01) : 123 - 126
  • [42] Trace element analysis in CRM of plant origin by inductively coupled plasma mass spectrometry
    Koplik, R
    Curdova, E
    Suchanek, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (3-4): : 449 - 451
  • [43] Inductively coupled plasma time of flight mass spectrometry for trace element and speciation analysis
    Emteborg, H
    Tian, XD
    Heisterkamp, M
    Adams, FC
    TRACE ELEMENTS IN MAN AND ANIMALS 10, 2000, : 1107 - 1110
  • [44] Neon inductively coupled plasma for laser ablation-inductively coupled plasma-mass spectrometry
    Petibon, CM
    Longerich, HP
    Horn, I
    Tubrett, MN
    APPLIED SPECTROSCOPY, 2002, 56 (05) : 658 - 664
  • [45] Trace element analysis in CRM of plant origin by inductively coupled plasma mass spectrometry
    R. Koplík
    E. E. Curdová
    M. Suchánek
    Fresenius' Journal of Analytical Chemistry, 1998, 360 : 449 - 451
  • [46] Development of in situ Li isotope analysis using laser ablation quadrupole inductively coupled plasma mass spectrometry
    Fan, Xuefei
    Sio, Corliss Kin, I
    Chu, Xu
    Jiang, Hehe
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (02)
  • [47] Inter-element fractionation and correction in laser ablation inductively coupled plasma mass spectrometry
    Chen, ZX
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) : 1823 - 1828
  • [48] Analysis of In situ Pb Isotope in Sulfides by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang Wen
    Hu Zhao-Chu
    Jin Zhen-Min
    Liu Yong-Sheng
    Ling Wen-Li
    Hu Qing-Hai
    Fu Jia-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 14 - 22
  • [50] Calibration Standard Samples for Multielement Analysis of Silicate Rocks Using Inductively Coupled Plasma Mass Spectrometry with Laser Ablation
    Palesskiy, S. V.
    Nikolaeva, I. V.