Human hip joint center analysis for biomechanical design of a hip joint exoskeleton

被引:0
|
作者
Wei Yang
Can-jun Yang
Ting Xu
机构
[1] Zhejiang University,State Key Laboratory of Fluid Power & Mechatronic Systems
关键词
Hip joint exoskeleton; Hip joint center; Compatible joint; Human-machine interaction force; TP242.6;
D O I
暂无
中图分类号
学科分类号
摘要
We propose a new method for the customized design of hip exoskeletons based on the optimization of the humanmachine physical interface to improve user comfort. The approach is based on mechanisms designed to follow the natural trajectories of the human hip as the flexion angle varies during motion. The motions of the hip joint center with variation of the flexion angle were measured and the resulting trajectory was modeled. An exoskeleton mechanism capable to follow the hip center’s movement was designed to cover the full motion ranges of flexion and abduction angles, and was adopted in a lower extremity assistive exoskeleton. The resulting design can reduce human-machine interaction forces by 24.1% and 76.0% during hip flexion and abduction, respectively, leading to a more ergonomic and comfortable-to-wear exoskeleton system. The human-exoskeleton model was analyzed to further validate the decrease of the hip joint internal force during hip joint flexion or abduction by applying the resulting design.
引用
收藏
页码:792 / 802
页数:10
相关论文
共 50 条
  • [41] INCONGRUENT SURFACES IN HUMAN HIP JOINT
    BULLOUGH, P
    GOODFELLOW, J
    GREENWALD, AS
    OCONNOR, J
    NATURE, 1968, 217 (5135) : 1290 - +
  • [42] PRENATAL DEVELOPMENT OF THE HUMAN HIP JOINT
    GARDNER, E
    GRAY, DJ
    AMERICAN JOURNAL OF ANATOMY, 1950, 87 (02): : 163 - 211
  • [43] Multivariable analysis for predicting lower limb muscular strength with a hip-joint exoskeleton
    Kang, Byungmun
    Lee, Changmin
    Kim, Dongwoo
    Lee, Hwang-Jae
    Lee, Dokwan
    Jeon, Hyung Gyu
    Kim, Yoonmyung
    Kim, Daeeun
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [44] Design and transmission performance analysis of planthopper hip joint gear
    Fu, Shengping
    He, Zenghuang
    Ye, Weixiong
    Li, Xudong
    Wang, Rui
    Sheng, Bin
    ADVANCES IN MECHANICAL ENGINEERING, 2024, 16 (01)
  • [45] Design and Dynamic Analysis of a Novel Biomimetic Robotics Hip Joint
    Cui, Bingyan
    Chen, Liwen
    Wang, Zhijun
    Zhao, Yuanhao
    Li, Zhanxian
    Jin, Zhenlin
    APPLIED BIONICS AND BIOMECHANICS, 2015, 2015
  • [46] An innovative design and structural mechanics analysis of artificial hip joint
    Qian, Zhihui
    Wang, Jiajia
    Ren, Lei
    Ren, Luquan
    Xu, Tao
    MANUFACTURING PROCESS AND EQUIPMENT, PTS 1-4, 2013, 694-697 : 3094 - +
  • [47] Evaluation of formal methods in hip joint center assessment: An in vitro analysis
    Lopomo, Nicola
    Sun, Lei
    Zaffagnini, Stefano
    Giordano, Giovanni
    Safran, Marc R.
    CLINICAL BIOMECHANICS, 2010, 25 (03) : 206 - 212
  • [48] The biomechanical and evolutionary adaptation of the lateralized hip joint surface in birds
    Sesic, Nenad
    Mihelic, Damir
    JOURNAL OF MORPHOLOGY, 2007, 268 (12) : 1133 - 1133
  • [49] BIOMECHANICAL DIFFERENCES IN CONVEX AND CONCAVE MEMBERS OF THE HIP-JOINT
    DEWIRE, P
    SMIKIN, PA
    ARTHRITIS AND RHEUMATISM, 1992, 35 (09): : S186 - S186
  • [50] Biomechanical factors influencing the beginning and development of osteoarthritis in the hip joint
    Horak Z.
    Kubovy P.
    Stupka M.
    Horakova J.
    Wiener Medizinische Wochenschrift, 2011, 161 (19-20) : 486 - 492