A new optical model for photomultiplier tubes

被引:0
|
作者
Yaoguang Wang
Guofu Cao
Liangjian Wen
Yifang Wang
机构
[1] Institute of High Energy Physics,
[2] University of Chinese Academy of Sciences,undefined
[3] State Key Laboratory of Particle Detection and Electronics,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
It is critical to construct an accurate optical model of photomultiplier tubes (PMTs) in many applications to describe the angular and spectral responses of the photon detection efficiency (PDE) of the PMTs in their working media. In this study, we propose a new PMT optical model to describe both light interactions with the PMT window and optical processes inside PMTs with reasonable accuracy based on the optics theory and a GEANT4-based simulation toolkit. The proposed model builds a relationship between the PDE and the underlying processes that the PDE relies on. This model also provides a tool to transform the PDE measured in one working medium (like air) to the PDE in other media (like water, liquid scintillator, etc). Using two 20″\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$^{\prime \prime }$$\end{document} MCP-PMTs and one 20″\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$^{\prime \prime }$$\end{document} dynode PMT, we demonstrate a complete procedure to obtain the key parameters used in the model from experimental data, such as the optical properties of the antireflective coating and photocathode of the three PMTs. The proposed model can effectively reproduce the angular responses of the quantum efficiency of PMTs, even though an ideally uniform photocathode is assumed in the model. Interestingly, the proposed model predicts a similar level (20–30%) of light yield excess observed in the experimental data of many liquid scintillator-based neutrino detectors, compared with that predicted at the stage of detector design. However, this excess has never been explained, and the proposed PMT model provides a good explanation for it, which highlights the imperfections of PMT models used in their detector simulations.
引用
收藏
相关论文
共 50 条
  • [31] A new TDCR-LS Counter using Channel photomultiplier tubes
    Ivan, C.
    Cassette, P.
    Sahagia, Maria
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 1006 - 1011
  • [32] Photomultiplier tubes - Near-infrared photodetectors enable new applications
    Hergert, E
    LASER FOCUS WORLD, 2004, 40 (06): : 131 - 133
  • [33] Performance of photomultiplier tubes for cryogenic applications
    Carbonara, Francesco
    Cocco, Alfredo G.
    Fiorillo, Giuliana
    Gallo, Valentina S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 271 - 275
  • [34] GAIN DRIFT CHARACTERISTICS OF PHOTOMULTIPLIER TUBES
    PERSYK, DE
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P106 - P106
  • [35] High Sensitivity THz Photomultiplier Tubes
    Buchmann, Tobias O.
    Lange, Simon L.
    Sebek, Matej
    Kawai, Naoya
    Jepsen, Peter Uhd
    2022 47TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ 2022), 2022,
  • [36] Surface sensitivity of multianode photomultiplier tubes
    Korpar, S
    Bizjak, I
    Gorisek, A
    Krizan, P
    Pestotnik, R
    Staric, M
    Stanovnik, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2): : 391 - 394
  • [37] USE OF PHOTOMULTIPLIER TUBES FOR PHOTON COUNTING
    YOUNG, AT
    APPLIED OPTICS, 1971, 10 (07): : 1681 - &
  • [38] AUTOMATIC GAIN CONTROL FOR PHOTOMULTIPLIER TUBES
    ROSENTHAL, JA
    FIEHRER, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (11): : 1560 - +
  • [39] METHOD OF LIGHT LOSS IN PHOTOMULTIPLIER TUBES
    PILLSBURY, D
    AMERICAN JOURNAL OF PHYSICS, 1961, 29 (09) : 651 - &
  • [40] Low temperature test of photomultiplier tubes
    Appl Radiat Isot, 6-7 (495):