Evaluation of spatial-encoding-related geometric distortion in magnetic resonance imaging

被引:0
|
作者
Cheol Pyo Hong
Dong Hoon Lee
Man Woo Lee
Youngkeun Woo
机构
[1] Yonsei University,Department of Radiological Science and Institute of Health Science
[2] Samsung Electronics Co.,Research and Development, Health & Medical Equipment
[3] LTD,Department of Physical Therapy, College of Alternative Medicine
[4] Jeonju University,undefined
来源
关键词
Spatial Encoding; Geometric distortion; MRI;
D O I
暂无
中图分类号
学科分类号
摘要
This study demonstrated the characteristics of spatial encoding-related geometric distortion in magnetic resonance imaging (MRI) by using a phantom with known physical dimensions to detect geometric distortion in MR scans. The amount of distortion was calculated as the difference between the physical coordinates of control points in the phantom and those of the corresponding points in the distorted MR image of the phantom. The phase and the frequency encoding directions were swapped to acquire a phantom image for movement of a patient table 120 mm to the right and left, allowing comprehensive distortion mapping over the isocentric plane and the entire field of view (FOV) along the spatial encoding. The geometric distortion of phase encoding directions over the entire FOV was small compared to the distortion of frequency encoding directions. The maximum absolute deviations were 28.00 mm and 20.00 mm along the frequency and the phase encoding directions over the entire FOV, respectively. The mean absolute deviations along the frequency and the phase encoding directions were 2.85 mm and 1.97 mm, respectively. Although geometric distortion along the phase encoding axis near the isocenter was small, the distortion increased slightly toward the peripheral regions. The distortion of the phase encoding direction in the peripheral region can be severely affected by the imaging gradient’s nonlinearity.
引用
收藏
页码:2068 / 2072
页数:4
相关论文
共 50 条
  • [21] Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes
    Rostami, A.
    Naseri, Sh
    Momennezhad, M.
    Zare, H.
    Anvari, K.
    Badkhor, H. R. Sayah
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 733 - 742
  • [22] Evaluation of contrast and denoising effects related to imaging parameters of compressed sensitivity encoding in contrast-enhanced magnetic resonance imaging
    Yasuo Takatsu
    Masafumi Nakamura
    Takanobu Yamashiro
    Atsushi Ikemoto
    Satoshi Sawa
    Masanobu Nakamura
    Tosiaki Miyati
    Radiological Physics and Technology, 2021, 14 : 193 - 202
  • [23] Evaluation of contrast and denoising effects related to imaging parameters of compressed sensitivity encoding in contrast-enhanced magnetic resonance imaging
    Takatsu, Yasuo
    Nakamura, Masafumi
    Yamashiro, Takanobu
    Ikemoto, Atsushi
    Sawa, Satoshi
    Nakamura, Masanobu
    Miyati, Tosiaki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (02) : 193 - 202
  • [24] CHARACTERIZATION OF SPATIAL DISTORTION IN MAGNETIC-RESONANCE-IMAGING AND ITS IMPLICATIONS FOR STEREOTAXIC SURGERY
    SUMANAWEERA, TS
    ADLER, JR
    NAPEL, S
    GLOVER, GH
    NEUROSURGERY, 1994, 35 (04) : 696 - 703
  • [25] Magnetic Resonance Imaging Distortion in Functional Neurosurgery
    Sankar, Tejas
    Lozano, Andres M.
    WORLD NEUROSURGERY, 2011, 75 (01) : 29 - 31
  • [26] Impact Assessment of Systemic Geometric Distortion in 1.5T Magnetic Resonance Imaging Simulation through Three-dimensional Geometric Distortion Phantom on Dosimetric Accuracy for Magnetic Resonance Imaging-only Prostate Treatment Planning
    Chaknam, Korawig
    Worapruekjaru, Ladawan
    Suphaphong, Sithiphong
    Stansook, Nualjun
    Sodkokkruad, Prapa
    Asavaphatiboon, Sawwanee
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 356 - 362
  • [27] Spatial transformations of diffusion tensor magnetic resonance imaging using certain geometric operations
    Bahuguna, Sandeep K.
    Petwal, Kailash C.
    INTERNATIONAL JOURNAL OF THE PHYSICAL SCIENCES, 2010, 5 (07): : 940 - 954
  • [28] Design and construction of a customizable phantom for the characterization of the three-dimensional magnetic resonance imaging geometric distortion
    Torfeh, Tarraf
    Hammoud, Rabih
    Paloor, Satheesh
    Arunachalam, Yoganathan
    Aouadi, Souha
    Al-Hammadi, Noora
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 149 - 157
  • [29] Derivative encoding for parallel magnetic resonance imaging
    Shen, Jun
    MEDICAL PHYSICS, 2011, 38 (10) : 5582 - 5589
  • [30] Encoding Textual Information in Magnetic Resonance Imaging
    Anisimov, Nikolay V.
    Pavlova, Olga S.
    APPLIED MAGNETIC RESONANCE, 2018, 49 (02) : 165 - 174