Dose reduction from loss of backscatter in superficial x-ray radiation therapy with the Pantak SXT 150 unit

被引:0
|
作者
B. J. Healy
S. Sylvander
K. N. Nitschke
机构
[1] Princess Alexandra Hospital,Southern Zone Radiation Oncology Service
[2] Radiation Oncology Queensland,Mater Centre
来源
Australasian Physics & Engineering Sciences in Medicine | 2008年 / 31卷
关键词
superficial x-ray therapy; backscatter; lead shielding;
D O I
暂无
中图分类号
学科分类号
摘要
Loss of backscatter has been measured for a Pantak Therapax SXT 150 superficial x-ray therapy unit. Ionisation chamber measurements at the surface were performed in solid water with and without underlying lead to confirm the applicability of previous published measurements. Measurements of loss of backscatter with and without lead allowed the effect of underlying lead to be separated from the effect of loss of backscatter. It was found that the difference between the effect of lead and that of air on surface dose is minimal for solid water phantom thickness exceeding 3 cm. Differences up to 3% in dose reduction at the surface were found between this work and previous published results with different x-ray units.
引用
收藏
页码:49 / 55
页数:6
相关论文
共 50 条
  • [21] RADIATION DOSE TO GONADS FROM DIAGNOSTIC X-RAY EXPOSURE
    LINCOLN, TA
    GUPTON, ED
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1958, 166 (03): : 233 - 239
  • [22] Measurement of effects of nasal and facial shields on delivered radiation dose for superficial x-ray treatments
    Yu, Peter K. N.
    Butson, Martin J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : N95 - N102
  • [23] Radiation dose reduction with digital flat panel cardiac x-ray imaging
    Raman, SV
    Niklason, L
    Benali, K
    Bush, CA
    EUROPEAN HEART JOURNAL, 2002, 23 : 71 - 71
  • [24] Monte Carlo modeling of radiation dose from radiation therapy with superficial x-rays
    Barghash, Reham
    Martin, Tiffany W.
    Prebble, Amber R.
    Leary, Del
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [25] STATE PRIMARY STANDARD FOR UNIT OF EXPOSED DOSE OF X-RAY AND GAMMA-RADIATION
    YUDIN, MF
    KOCHINA, MP
    OSTROMUKHOVA, GP
    KONONOVA, RF
    MEASUREMENT TECHNIQUES-USSR, 1972, 15 (02): : 185 - +
  • [26] EFFECT OF SHADOW TRAYS ON DOSE TO SUPERFICIAL LAYERS OF SKIN IN 6 MV X-RAY THERAPY
    RAO, PS
    PILLAI, K
    GREGG, EC
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (03): : 445 - &
  • [27] SURFACE DOSE FROM MEGAVOLTAGE X-RAY THERAPY MACHINES
    GAGNON, W
    GRANT, W
    PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (02): : 260 - 260
  • [28] RADIATION DOSE TO GONADS DURING X-RAY THERAPY WITH A 31 MEV BETATRON
    STROMME, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (01): : 117 - &
  • [29] Dose calculation algorithm for a compact x-ray source in Microbeam Radiation Therapy
    Ahmed, M.
    Wilkens, J. J.
    Bartzsch, S.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S751 - S752
  • [30] RADIATION-DOSE TO CHILDREN FROM X-RAY AND RADIOISOTOPE EXAMINATIONS
    BUSHONG, SC
    GLAZE, D
    GLAZE, S
    SINGLETON, E
    HEALTH PHYSICS, 1978, 35 (05): : 720 - 721