Effects of pH on the electrochemical behaviour of titanium alloys for implant applications

被引:0
|
作者
Maria E. P. Souza
Lonetá Lima
Carmo R. P. Lima
Cecília A. C. Zavaglia
Célia M. A. Freire
机构
[1] State University of Campinas––UNICAMP,Department of Materials Engineering
来源
Journal of Materials Science: Materials in Medicine | 2009年 / 20卷
关键词
Titanium Alloy; Electrochemical Impedance Spectroscopy; Barrier Layer; Passive Film; Open Circuit Potential;
D O I
暂无
中图分类号
学科分类号
摘要
The electrochemical behaviour of two commercial titanium alloys Ti-6Al-4 V (ASTM F136) and Ti-13Nb-13Zr (ASTM F1713) was investigated in Ringer physiological solution at two pH values (5.5 and 7.0). The corrosion properties were examined by using electrochemical techniques: Potentiodynamic anodic polarization, cyclic polarization and electrochemical impedance spectroscopy (EIS). The electrochemical corrosion properties of both alloys at different conditions were measured in terms of corrosion potential (Ecorr), corrosion current density (icorr) and passivation current density (ipass). Equivalent electrical circuits were used to modulate EIS data, in order to characterize alloys surface and better understanding the pH effect on the interface alloy/solution.
引用
收藏
页码:549 / 552
页数:3
相关论文
共 50 条
  • [31] Effect of Mo content on electrochemical behaviour of TiMo alloys for dental applications
    Mareci, D.
    Chelariu, R.
    Gordin, D. M.
    Romas, M.
    Sutiman, D.
    Gloriant, T.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2010, 61 (10): : 829 - 837
  • [32] Electrochemical behaviour of oxidized NiTi shape memory alloys for biomedical applications
    Michiardi, A.
    Aparicio, C.
    Planell, J. A.
    Gil, F. J.
    SURFACE & COATINGS TECHNOLOGY, 2007, 201 (14): : 6484 - 6488
  • [33] CORROSION BEHAVIOUR OF ELECTROPOLISHED IMPLANT ALLOYS
    Munroe, Norman
    Haider, Waseem
    Datye, Amit
    Wu, Kuang-His
    SMST-2007: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SHAPE MEMORY AND SUPERELASTIC TECHNOLOGIES, 2008, : 307 - +
  • [34] ANODIC BEHAVIOUR OF COMMERCIAL TITANIUM ALLOYS IN SULPHURIC ACID ENVIRONMENT - INFLUENCE OF PH AND OF COMPOSITION
    PETIT, JA
    DABOSI, F
    MEMOIRES SCIENTIFIQUES DE LA REVUE DE METALLURGIE, 1971, 68 (09): : 595 - &
  • [35] Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications
    González, JEG
    Mirza-Rosca, JC
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 471 (02): : 109 - 115
  • [36] PLASTIC BEHAVIOUR AND CRISTALLOGRAPHIC TEXTURE OF ALPHA TITANIUM ALLOYS FOR HEAT RESISTANT APPLICATIONS
    Gaiani, S.
    Colombini, E.
    Veronesi, P.
    Poli, G.
    Pribosic, I.
    METALLURGIA ITALIANA, 2013, (05): : 31 - 39
  • [37] Effect of replacement of vanadium by iron on the electrochemical behaviour of titanium alloys in simulated physiological media
    Mareci, D.
    Lucero, V.
    Mirza, J.
    REVISTA DE METALURGIA, 2009, 45 (01) : 32 - 41
  • [38] Study of the biotribocorrosion behaviour of titanium biomedical alloys in simulated body fluids by electrochemical techniques
    Dimah, M. K.
    Devesa Albeza, F.
    Amigo Borras, V.
    Igual Munoz, A.
    WEAR, 2012, 294 : 409 - 418
  • [39] Electrochemical anodic behaviour of alloys
    Muller, WJ
    ZEITSCHRIFT FUR ELEKTROCHEMIE UND ANGEWANDTE PHYSIKALISCHE CHEMIE, 1935, 41 : 774 - 778
  • [40] Suitability of Magnesium and Titanium alloys as implant materials
    Shivappa, Z. Edward
    Shivappa, S.
    Mohan, S.
    MATERIALS TODAY-PROCEEDINGS, 2022, 55 : 470 - 473