Behaviour and Modeling of the Bearing Capacity of Shear Stud Connectors

被引:0
|
作者
Yuhong Ling
Zhaoyi Zheng
T. Y. Yang
Hongwei Ma
机构
[1] South China University of Technology,School of Civil Engineering and Transportation
[2] State Key Laboratory of Subtropical Building Science,Department of Civil Engineering
[3] The University of British Columbia,undefined
关键词
Shear connector; Finite element analysis; Bearing capacity; Design formula;
D O I
暂无
中图分类号
学科分类号
摘要
The bearing capacity of shear stud connectors from the simplified design equations in different building codes tends to be underestimated because of a relatively large safety factor. Finite element analysis using ABAQUS was carried out to simulate the force–deformation response of shear stud. The finite element model was verified by using push-out tests, and detailed parametric numerical studies were conducted to investigate the force–deformation response of different shear stud configurations. A new design equation was derived from linear regression based on the results of the parametric studies. The presented equation shows better agreement with the experimental data. Detailed comparison between the proposed equation and existing design equation in China code for shear stud strength was carried out. The results show significant reduction in the construction cost when the new equation is used.
引用
收藏
页码:650 / 659
页数:9
相关论文
共 50 条
  • [41] Effect of concrete cracks on the corrosion of stud shear connectors
    Xu, X. Q.
    Yu, Z. W.
    He, D. Y.
    Tan, H. M.
    Zeng, S. W.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, LIFE-CYCLE SUSTAINABILITY AND INNOVATIONS, 2021, : 619 - 623
  • [42] Design Codes on Stud Shear Connectors for New Details
    Shim, Chang-Su
    Kim, Dong-Wook
    COMPOSITE CONSTRUCTION IN STEEL AND CONCRETE VII, 2016, : 703 - 711
  • [43] THE STRENGTH OF STUD SHEAR CONNECTORS AT LOW-TEMPERATURES
    VANDALEN, K
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1983, 10 (03) : 429 - 436
  • [44] FRICTION WELDING STUD SHEAR CONNECTORS TO STEEL BEAMS
    GILMOUR, RS
    METAL CONSTRUCTION AND BRITISH WELDING JOURNAL, 1974, 6 (05): : 150 - 152
  • [45] Experimental investigation and design of corroded stud shear connectors
    Chen, Ju
    Zhao, Yu-xi
    Wu, Lin
    Jin, Wei-liang
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (02) : 218 - 226
  • [46] Influence of longitudinal prestress on the shear resistance of prefabricated shear stud connectors
    Gao, Yanmei
    Zhang, Fanghua
    Huang, Tao
    Hu, Cheng
    Liu, Zhongliang
    Li, Chengjun
    STRUCTURES, 2023, 57
  • [47] Different load bearing mechanisms in headed stud shear connectors for composite beams with profiled steel sheeting
    Vigneri, Valentino
    Odenbreit, Christoph
    Lam, Dennis
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2019, 12 (03): : 184 - 190
  • [49] BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL-CONCRETE BEAMS INCORPORATING RECYCLED CONCRETE
    Deo, Vivit Nehaal
    Tan, Ee Loon
    Tam, Vivian
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 66 - 73
  • [50] Neural network prediction of the ultimate capacity of shear stud connectors on composite beams with profiled steel sheeting
    Koroglu, M. A.
    Koken, A.
    Arslan, M. H.
    Cevik, A.
    SCIENTIA IRANICA, 2013, 20 (04) : 1101 - 1113