Lateral flow immunoassay-based absolute point-of-care technique for authentication of meat and commercial meat products

被引:0
|
作者
Rituparna Banerjee
Naveena B Maheswarappa
Subhasish Biswas
Sowmya Dasoju
Sukhdeo Barbuddhe
Vishnuraj M. Rajan
Gopal Patra
Debasish Bhattacharyya
机构
[1] ICAR-National Research Centre on Meat,Meat Proteomics Lab
[2] West Bengal University of Animal and Fishery Sciences,Department of Livestock Products Technology
来源
关键词
Point-of-care; Lateral flow immunoassay; Immunoglobulins; Gold nanoparticles; Species authentication; Extraction protocol; Commercial meat samples;
D O I
暂无
中图分类号
学科分类号
摘要
Point-of-care (POC) assay is an emerging technique for rapid initial screening of meat fraud incidents in a resource-limited environment. To achieve this goal, a simple extraction protocol is proposed for efficient recovery of meat proteins from raw, heat-processed, and commercial samples as well as meat offals without utilizing sophisticated laboratory settings. A sandwich-format lateral flow immunoassay (LFIA) was developed based on gold nanoparticles as labels and immunoglobulins (IgG and IgY) as biomarkers for meat species identification in raw and cooked meat mixes. The test system showed a sensitivity of 10 ng/mL allowing the detection of as low as 0.063% pork and chicken meat and 0.125% sheep meat (lamb) in meat mixes within 15 min including sample preparation. Reproducibility of the assay was confirmed by the fully consistent intra- and inter-laboratory tests and RT-PCR method. The current study developed a field-deployable extraction technique and highly-specific, sensitive, reproducible, cost-effective, and user-friendly LFIA-based assay for rapid species authentication in raw, cooked, and commercial meat samples and meat offals.
引用
收藏
页码:772 / 782
页数:10
相关论文
共 50 条
  • [11] Validation of Point-of-Care Device for Rapid Detection of Salmonella enterica in Meat Products
    Vinayaka, Aaydha Chidambara
    Huynh, Van Ngoc
    Quyen, Than Linh
    Nguyen, Trieu
    Golabi, Mohsen
    Madsen, Mogens
    Bang, Dang Duong
    Wolff, Anders
    ANALYTICAL CHEMISTRY, 2023, 95 (34) : 12656 - 12663
  • [12] A glass fiber sheet-based electroosmotic lateral flow immunoassay for point-of-care testing
    Oyama, Yuriko
    Osaki, Toshihisa
    Kamiya, Koki
    Kawano, Ryuji
    Honjoh, Tsutomu
    Shibata, Haruki
    Ide, Toru
    Takeuchi, Shoji
    LAB ON A CHIP, 2012, 12 (24) : 5155 - 5159
  • [13] Lateral Flow Immunoassay to Detect the Addition of Beef, Pork, Lamb, and Horse Muscles in Raw Meat Mixtures and Finished Meat Products
    Zvereva, Elena A.
    Popravko, Demid S.
    Hendrickson, Olga D.
    Vostrikova, Natalia L.
    Chernukha, Irina M.
    Dzantiev, Boris B.
    Zherdev, Anatoly V.
    FOODS, 2020, 9 (11)
  • [14] Halal authentication using lateral flow devices for detection of pork adulteration in meat products: a review
    Nhari, Raja Mohd Hafidz Raja
    Soh, Jun Hui
    Mokhtar, Nur Fadhilah Khairil
    Mohammad, Nurhidayatul Asma
    Hashim, Amalia Mohd
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2023, 40 (08): : 971 - 980
  • [15] Evaluation of immunoassay-based MMP-8 detection in gingival crevicular fluid on a point-of-care platform
    Munjal, S. K.
    Prescher, N.
    Struck, F.
    Sorsa, T.
    Maier, K.
    Netuschil, L.
    ORAL-BASED DIAGNOSTICS, 2007, 1098 : 490 - 492
  • [16] Novel integration of lateral flow strip and point-of-care isothermal amplification techniques for meat adulteration detection: A comprehensive review
    Feng, Jinchao
    Lan, Hangzhen
    Wu, Zhen
    Pan, Daodong
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2024, 152
  • [17] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [18] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    Biosensors and Bioelectronics, 2021, 168
  • [19] Fluorescence lateral flow immunoassay based point-of-care nanodiagnostics for orthopedic implant-associated infection
    Borse, Vivek
    Srivastava, Rohit
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 280 : 24 - 33
  • [20] POINT-OF-CARE TEST FOR C-REACTIVE PROTEIN BY A FLUORESCENCE-BASED LATERAL FLOW IMMUNOASSAY
    Gu, Yongbin
    Yang, Yongliang
    Zhang, Jing
    Ge, ShengXiang
    Tang, Zhanghong
    Qiu, Xianbo
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (06) : 635 - 645