Coronary artery calcium scoring with photon-counting CT: first in vivo human experience

被引:0
|
作者
Rolf Symons
Veit Sandfort
Marissa Mallek
Stefan Ulzheimer
Amir Pourmorteza
机构
[1] Radiology and Imaging Sciences - National Institutes of Health Clinical Center,Department of Imaging & Pathology
[2] University Hospitals Leuven,Department of Radiology and Imaging Sciences
[3] Siemens Healthcare GmbH,Department of Radiology and Imaging Sciences
[4] Emory University School of Medicine,undefined
[5] Winship Cancer Institute of Emory University,undefined
关键词
Coronary artery calcium score; Photon-counting CT; Radiation dose reduction;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the performance of photon-counting detector (PCD) computed tomography (CT) for coronary artery calcium (CAC) score imaging at standard and reduced radiation doses compared to conventional energy-integrating detector (EID) CT. A dedicated cardiac CT phantom, ten ex vivo human hearts, and ten asymptomatic volunteers underwent matched EID and PCD CT scans at different dose settings without ECG gating. CAC score, contrast, and contrast-to-noise ratio (CNR) were calculated in the cardiac CT phantom. CAC score accuracy and reproducibility was assessed in the ex vivo hearts. Standard radiation dose (120 kVp, reference mAs = 80) in vivo CAC scans were compared against dose-reduced CAC scans (75% dose reduction; reference mAs = 20) for image quality and CAC score reproducibility. Interstudy agreement was assessed by using intraclass correlation (ICC), linear regression, and Bland–Altman analysis with 95% confidence interval limits of agreement (LOA). Calcium-soft tissue contrast and CNR were significantly higher for the PCD CAC scans in the cardiac CT phantom (all P < 0.01). Ex vivo hearts: CAC score reproducibility was significantly higher for the PCD scans at the lowest dose setting (50 mAs) (P = 0.002); score accuracy was similar for both detector systems at all dose settings. In vivo scans: the agreement between standard dose and low dose CAC score was significantly better for the PCD than for the EID with narrower LOA in Bland–Altman analysis, linear regression slopes closer to 1 (0.96 vs. 0.84), and higher ICC values (0.98 vs. 0.93, respectively). Phantom and in vivo human studies showed PCD may significantly improve CAC score image quality and/or reduce CAC score radiation dose while maintaining diagnostic image quality.
引用
收藏
页码:733 / 739
页数:6
相关论文
共 50 条
  • [41] Photon-Counting CT High-Resolution Imaging of Coronary Stents
    Mannil, Manoj
    Hickethier, Tilman
    von Spiczak, Jochen
    Baer, Matthias
    Henning, Andre
    Hertel, Madeleine
    Schmidt, Bernhard
    Flohr, Thomas
    Maintz, David
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 143 - 149
  • [42] Photon-counting CT: A Step Change Leading to a Revolution in Coronary Imaging
    Williams, Michelle C.
    Newby, David E.
    RADIOLOGY, 2023, 307 (05)
  • [43] Coronary artery disease detection using deep learning and ultrahigh-resolution photon-counting coronary CT angiography
    Brendel, Jan M.
    Walterspiel, Jonathan
    Hagen, Florian
    Kuebler, Jens
    Brendlin, Andreas S.
    Afat, Saif
    Paul, Jean-Francois
    Kuestner, Thomas
    Nikolaou, Konstantin
    Gawaz, Meinrad
    Greulich, Simon
    Krumm, Patrick
    Winkelmann, Moritz T.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2025, 106 (02) : 68 - 75
  • [44] Radiation Dose Reduction for Coronary Artery Calcium Scoring Using a Virtual Noniodine Algorithm on Photon-Counting Detector Computed-Tomography Phantom Data
    Fink, Nicola
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    O'Doherty, Jim
    Griffith III, Joseph P. P.
    Pinos, Daniel
    Tesche, Christian
    Ricke, Jens
    Willemink, Martin J.
    Varga-Szemes, Akos
    Emrich, Tilman
    DIAGNOSTICS, 2023, 13 (09)
  • [45] Photon-counting CT: Embracing the Change
    Ananthakrishnan, Lakshmi
    RADIOGRAPHICS, 2023, 43 (05)
  • [46] Photon-counting CT in lung imaging
    Tarnoki, adam Domonkos
    Tarnoki, David Laszlo
    Maurovich-Horvat, Pal
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2025, 19 (02) : 77 - 81
  • [47] Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck First In Vivo Human Results
    Symons, Rolf
    Reich, Daniel S.
    Bagheri, Mohammadhadi
    Cork, Tyler E.
    Krauss, Bernhard
    Ulzheimer, Stefan
    Kappler, Steffen
    Bluemke, David A.
    Pourmorteza, Amir
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 135 - 142
  • [48] Abdominal applications of photon-counting CT
    Khanungwanitkul, Khanin
    Sliwicka, Olga
    Schwartz, Fides Regina
    BRITISH JOURNAL OF RADIOLOGY, 2024,
  • [49] First Clinical Photon-counting Detector CT System: Technical Evaluation
    Rajendran, Kishore
    Petersilka, Martin
    Henning, Andre
    Shanblatt, Elisabeth R.
    Schmidt, Bernhard
    Flohr, Thomas G.
    Ferrero, Andrea
    Baffour, Francis
    Diehn, Felix E.
    Yu, Lifeng
    Rajiah, Prabhakar
    Fletcher, Joel G.
    Leng, Shuai
    McCollough, Cynthia H.
    RADIOLOGY, 2022, 303 (01) : 130 - 138
  • [50] Photon-counting detector CT - first experiences in the field of musculoskeletal radiology
    Bette, Stefanie
    Risch, Franka
    Becker, Judith
    Popp, Daniel
    Decker, Josua A.
    Kaufmann, David
    Friedrich, Lena
    Scheurig-Muenkler, Christian
    Schwarz, Florian
    Kroencke, Thomas J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2025, 197 (01): : 34 - 43