Coronary artery calcium scoring with photon-counting CT: first in vivo human experience

被引:0
|
作者
Rolf Symons
Veit Sandfort
Marissa Mallek
Stefan Ulzheimer
Amir Pourmorteza
机构
[1] Radiology and Imaging Sciences - National Institutes of Health Clinical Center,Department of Imaging & Pathology
[2] University Hospitals Leuven,Department of Radiology and Imaging Sciences
[3] Siemens Healthcare GmbH,Department of Radiology and Imaging Sciences
[4] Emory University School of Medicine,undefined
[5] Winship Cancer Institute of Emory University,undefined
关键词
Coronary artery calcium score; Photon-counting CT; Radiation dose reduction;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the performance of photon-counting detector (PCD) computed tomography (CT) for coronary artery calcium (CAC) score imaging at standard and reduced radiation doses compared to conventional energy-integrating detector (EID) CT. A dedicated cardiac CT phantom, ten ex vivo human hearts, and ten asymptomatic volunteers underwent matched EID and PCD CT scans at different dose settings without ECG gating. CAC score, contrast, and contrast-to-noise ratio (CNR) were calculated in the cardiac CT phantom. CAC score accuracy and reproducibility was assessed in the ex vivo hearts. Standard radiation dose (120 kVp, reference mAs = 80) in vivo CAC scans were compared against dose-reduced CAC scans (75% dose reduction; reference mAs = 20) for image quality and CAC score reproducibility. Interstudy agreement was assessed by using intraclass correlation (ICC), linear regression, and Bland–Altman analysis with 95% confidence interval limits of agreement (LOA). Calcium-soft tissue contrast and CNR were significantly higher for the PCD CAC scans in the cardiac CT phantom (all P < 0.01). Ex vivo hearts: CAC score reproducibility was significantly higher for the PCD scans at the lowest dose setting (50 mAs) (P = 0.002); score accuracy was similar for both detector systems at all dose settings. In vivo scans: the agreement between standard dose and low dose CAC score was significantly better for the PCD than for the EID with narrower LOA in Bland–Altman analysis, linear regression slopes closer to 1 (0.96 vs. 0.84), and higher ICC values (0.98 vs. 0.93, respectively). Phantom and in vivo human studies showed PCD may significantly improve CAC score image quality and/or reduce CAC score radiation dose while maintaining diagnostic image quality.
引用
收藏
页码:733 / 739
页数:6
相关论文
共 50 条
  • [1] Coronary artery calcium scoring with photon-counting CT: first in vivo human experience
    Symons, Rolf
    Sandfort, Veit
    Mallek, Marissa
    Ulzheimer, Stefan
    Pourmorteza, Amir
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (04): : 733 - 739
  • [2] Virtual Noncontrast CT for Coronary Artery Calcification Scoring Using Photon-Counting CT
    Sakuma, Hajime
    RADIOLOGY, 2024, 310 (03)
  • [3] Virtual calcium removal in calcified coronary arteries with photon-counting detector CT-first in-vivo experience
    Mergen, Victor
    Rusek, Stephane
    Civaia, Filippo
    Rossi, Philippe
    Rajagopal, Rengarajan
    Battig, Eduardo
    Manka, Robert
    Candreva, Alessandro
    Eberhard, Matthias
    Alkadhi, Hatem
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [4] Coronary CT Angiography with Photon-counting CT: First-In-Human Results
    Si-Mohamed, Salim A.
    Boccalini, Sara
    Lacombe, Hugo
    Diaw, Adja
    Varasteh, Mohammad
    Rodesch, Pierre-Antoine
    Dessouky, Riham
    Villien, Marjorie
    Tatard-Leitman, Valerie
    Bochaton, Thomas
    Coulon, Philippe
    Yagil, Yoad
    Lahoud, Elias
    Erhard, Klaus
    Riche, Benjamin
    Bonnefoy, Eric
    Rioufol, Gilles
    Finet, Gerard
    Bergerot, Cyrille
    Boussel, Loic
    Greffier, Joel
    Douek, Philippe C.
    RADIOLOGY, 2022, 303 (02)
  • [5] Coronary Artery Calcium Scoring Using Virtual Versus True Noncontrast Images From Photon-Counting Coronary CT Angiography
    Haag, Nina P.
    Michael, Arwed E.
    Lennartz, Simon
    Panknin, Christoph
    Niehoff, Julius H.
    Borggrefe, Jan
    Shahzadi, Iram
    Zwanenburg, Alex
    Kroeger, Jan Robert
    RADIOLOGY, 2024, 310 (03)
  • [6] Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT-First Evidence from Phantom and In-Vivo Scans
    Eberhard, Matthias
    Mergen, Victor
    Higashigaito, Kai
    Allmendinger, Thomas
    Manka, Robert
    Flohr, Thomas
    Schmidt, Bernhard
    Euler, Andre
    Alkadhi, Hatem
    DIAGNOSTICS, 2021, 11 (09)
  • [7] Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes: a dynamic phantom study
    Dobrolinska, Magdalena M. M.
    van der Werf, Niels R. R.
    van der Bie, Judith
    de Groen, Joel
    Dijkshoorn, Marcel
    Booij, Ronald
    Budde, Ricardo P. J.
    Greuter, Marcel J. W.
    van Straten, Marcel
    EUROPEAN RADIOLOGY, 2023, 33 (07) : 4668 - 4675
  • [8] Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes: a dynamic phantom study
    Magdalena M. Dobrolinska
    Niels R. van der Werf
    Judith van der Bie
    Joël de Groen
    Marcel Dijkshoorn
    Ronald Booij
    Ricardo P. J. Budde
    Marcel J. W. Greuter
    Marcel van Straten
    European Radiology, 2023, 33 : 4668 - 4675
  • [9] First human imaging with MARS photon-counting CT
    Panta, Raj Kumar
    Butler, Anthony P. H.
    Butler, Philip H.
    de Ruiter, Niels J. A.
    Bell, Stephen T.
    Walsh, Michael F.
    Doesburg, Robert M. N.
    Chernoglazov, Alexander, I
    Goulter, Brian P.
    Carbonez, Pierre
    Damet, Jerome
    Adebileje, Sikiru A.
    Alexander, Steven D.
    Amma, Maya R.
    Anjomrouz, Marzieh
    Asghariomabad, Fatemeh
    Atharifard, Ali
    Baer, Kenzie
    Bamford, Benjamin
    Bheesette, Srinidhi
    Chambers, Claire
    Dahal, Shishir
    Dalefield, Tara
    Duncan, Neryda
    Gieseg, Steven P.
    Gurney, Sam
    Healy, Joseph L.
    Hilton, Peter J.
    Kanithi, Preveenkumar
    Kirkbride, Tracy
    Lansley, Stuart P.
    Lowe, Chiara
    Mandalika, V. B. H.
    Marfo, Emmanuel
    Matanaghi, Aysouda
    Moghiseh, Mandieh
    Palmer, David
    Prebble, Hannah M.
    Raja, Aamir Y.
    Ramyar, Mohsen
    Renaud, Peter
    Schleich, Nanette
    Searle, Emily
    Shamshad, Muhammad
    Sheeja, Jereena S.
    Uddin, Rayhan
    Vanden Broeke, Lieza
    Vivek, V. S.
    Walker, E. Peter
    Wijesooriya, Manoj
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [10] Quantification accuracy in photon-counting detector CT for coronary artery calcium score: a pilot study
    Wang, Mengzhen
    Zhang, Xu
    Li, Jiqang
    Dong, Haipeng
    Xu, Zhihan
    Yan, Fuhua
    Yang, Wenjie
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (10): : 2181 - 2191