Thoron interference in radon exhalation rate measured by solid state nuclear track detector based can technique

被引:0
|
作者
B. K. Sahoo
T. K. Agarwal
J. J. Gaware
B. K. Sapra
机构
[1] Bhabha Atomic Research Centre,Radiological Physics and Advisory Division
关键词
Radon; Thoron; SSNTD; Exhalation; Online monitors;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the extent of thoron (220Rn) interference in the radon (222Rn) exhalation rate, measured by solid state nuclear track detector based ‘Can’ technique. Experiments were carried out following the standard procedure of ‘Can’ technique as well as active technique as a reference method for 222Rn and 220Rn exhalation measurements. It was found that 220Rn interference may lead to overestimation of 222Rn exhalation by a significant factor which can be as high as 12 depending upon the rate of 220Rn exhalation from samples.
引用
收藏
页码:1417 / 1420
页数:3
相关论文
共 50 条
  • [41] Soil gas radon–thoron monitoring in Dharamsala area of north-west Himalayas, India using solid state nuclear track detectors
    GULSHAN KUMAR
    ARVIND KUMAR
    VIVEK WALIA
    JITENDER KUMAR
    VIKASH GUPTA
    TSANYAO FRANK YANG
    SURINDER SINGH
    BIKRAMJIT SINGH BAJWA
    Journal of Earth System Science, 2013, 122 : 1295 - 1301
  • [42] MEASUREMENT OF INDOOR RADON, THORON AND THEIR PROGENY LEVELS IN DWELLINGS OF AMBALA DISTRICT, HARYANA, NORTHERN INDIA USING SOLID STATE NUCLEAR TRACK DETECTORS
    Mehta, Vimal
    Singh, S. P.
    Chauhan, R. P.
    Mudahar, G. S.
    ROMANIAN JOURNAL OF PHYSICS, 2014, 59 (7-8): : 834 - 845
  • [43] Estimation of indoor radon, thoron and their progeny using twin cup dosemeters with solid-state nuclear track detectors in Digbol of Upper Assam
    Barooah, D
    Laskar, I
    Goswami, AK
    Ramachandran, TV
    Nambi, KSV
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 461 - 463
  • [44] INDOOR RN-222 MEASUREMENTS IN SWEDEN WITH THE SOLID-STATE NUCLEAR TRACK DETECTOR TECHNIQUE
    JONSSON, G
    HEALTH PHYSICS, 1988, 54 (03): : 271 - 281
  • [45] Reactor fission rate measurement for miniature neutron source reactor by solid state nuclear track detector
    Li, YG
    Shi, YQ
    Zhang, YB
    Xia, P
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 589 - 591
  • [46] SOLID-STATE NUCLEAR TRACK DETECTORS IN RADON MEASUREMENTS INDOORS AND IN THE SOIL
    JONSSON, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 335 - 338
  • [47] INDOOR RADON MEASUREMENT METHODOLOGY BY SOLID-STATE NUCLEAR TRACK DETECTORS
    ESPINOSA, G
    RAMOS, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 161 (02): : 307 - 312
  • [48] ENVIRONMENTAL RADON STUDIES USING SOLID-STATE NUCLEAR TRACK DETECTORS
    RAMOLA, RC
    SINGH, M
    SINGH, S
    VIRK, HS
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1992, 15 (02) : 95 - 102
  • [49] Soil gas radon-thoron monitoring in Dharamsala area of north-west Himalayas, India using solid state nuclear track detectors
    Kumar, Gulshan
    Kumar, Arvind
    Walia, Vivek
    Kumar, Jitender
    Gupta, Vikash
    Yang, Tsanyao Frank
    Singh, Surinder
    Bajwa, Bikramjit Singh
    JOURNAL OF EARTH SYSTEM SCIENCE, 2013, 122 (05) : 1295 - 1301
  • [50] Study of uranium, radium and radon exhalation rate in soil samples from some areas of Kangra district, Himachal Pradesh, India using solid-state nuclear track detectors
    Sharma, DK
    Kumar, A
    Kumar, M
    Singh, S
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 363 - 366