Comparison of corneal measurements in normal and keratoconus eyes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Pentacam HR topographer

被引:0
|
作者
Omar M. Said
Mahmoud Kamal
Sara Tawfik
Ahmed Tamer Sayed Saif
机构
[1] Fayoum University,Department of Ophthalmology, Faculty of Medicine
来源
关键词
Topographic Corneal Thickness; Keratoconus; Pentacam; AS-OCT;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] The accuracy of anterior segment optical coherence tomography (AS-OCT) in localizing extraocular rectus muscles insertions
    Ngo, Cheryl S.
    Smith, David
    Kraft, Stephen P.
    JOURNAL OF AAPOS, 2015, 19 (03): : 233 - 236
  • [32] Characterisation of ectasia after penetrating keratoplasty in keratoconus eyes using anterior segment optical coherence tomography
    Weller, Julia M.
    Huebner, Lisa
    Kruse, Friedrich E.
    Tourtas, Theofilos
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (04) : 506 - 512
  • [33] Artificial Neural Network for Automated Keratoconus Detection Using a Combined Placido Disc and Anterior Segment Optical Coherence Tomography Topographer
    del Barrio, Jorge L. Alio
    Eldanasoury, Alaa M.
    Arbelaez, Juan
    Faini, Stefano
    Versaci, Francesco
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (04):
  • [34] Comparative study of anterior segment measurement with Pentacam and anterior segment optical coherence tomography
    Fu, Jing
    Wang, Xiaozhen
    Li, Shuning
    Wu, Gewei
    Wang, Ningli
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (06): : 627 - 631
  • [35] Anterior segment optical coherence tomography (AS-OCT) as a useful tool to identify retained lens fragments in the anterior chamber
    Akram, Haseeb
    Gunasekera, Chrishan Duminda
    Roberts, Harry
    Myerscough, James
    BMJ CASE REPORTS, 2021, 14 (10)
  • [36] Comparison of corneal thickness in patients with dry eye disease using the Pentacam rotating Scheimpflug camera and anterior segment optical coherence tomography
    Fujimoto, Keiichi
    Inomata, Takenori
    Okumura, Yuichi
    Iwata, Nanami
    Fujio, Kenta
    Eguchi, Atsuko
    Nagino, Ken
    Shokirova, Hurramhon
    Karasawa, Maria
    Murakami, Akira
    PLOS ONE, 2020, 15 (02):
  • [37] Reproducibility of Central Corneal Thickness Measurements in Normal Eyes Using the Zeiss Cirrus 5000 HD-OCT and Pentacam HR
    Baghdasaryan, Elmira
    Huang, Xiwen
    Marion, Kenneth M.
    Tepelus, Tudor C.
    Bagherinia, Homayoun
    Sadda, SriniVas R.
    Hsu, Hugo Y.
    OPEN OPHTHALMOLOGY JOURNAL, 2018, 12 : 72 - 83
  • [38] To compare central corneal thickness measurements obtained by Pentacam with those obtained by IOLMaster 700, Cirrus anterior segment optical coherence tomography and Tomey specular microscopy in normal healthy eyes
    Kumar, Kiran K.
    Prakash, Akshata A.
    Neeraja, T. G.
    Adappa, Karishma T.
    Prabha, Chandra T. S.
    Gangasagara, Suresh Babu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (07) : 1713 - 1717
  • [39] Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
    Hashemi, Hassan
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Momeni-Moghaddam, Hamed
    Khabazkhoob, Mehdi
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2022, 34 (02): : 216 - 222
  • [40] Anterior Segment Optical Coherence Tomography (AS-OCT) for the Visualization and Quantification of Dose-Dependent Ocular Toxicity
    Lin, Jonathan
    Luisi, Jonathan
    Karediya, Nishad
    Kraft, Edward R.
    Sharifi, Ardalan
    Schmitz-Brown, Mary E.
    Merkley, Kevin H.
    Gupta, Praveena
    Motamedi, Massoud
    OPHTHALMIC TECHNOLOGIES XXXII, 2022, 11941