12-month intravascular ultrasound observations from BiOSS® first-in-man studies

被引:0
|
作者
Robert J. Gil
Jacek Bil
Ricardo A. Costa
Katarzyna E. Gil
Dobrin Vassiliev
机构
[1] Central Clinical Hospital of the Ministry of Interior,Department of Invasive Cardiology
[2] Polish Academy of Science,Institute of Experimental and Clinical Medicine
[3] Instituto Dante Pazzanese de Cardiologia,undefined
[4] Alexandrovska University Hospital,undefined
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
Dedicated bifurcation stent; BiOSS Expert®; BiOSS LIM®; Sirolimus-eluting stent; Paclitaxel-eluting stent; IVUS; QCA;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to analyze the difference in neointima pattern assessed by intravascular ultrasound (IVUS) between two dedicated bifurcation stents, BiOSS® Expert and BiOSS® LIM at 12-month follow-up. This manuscript reports IVUS findings obtained from the analysis of patients enrolled into first-in-man registries initially assessing the BiOSS Expert® (paclitaxel) and BiOSS LIM® (sirolimus) stents. Quantitative angiographic analysis was performed pre, post-stenting, and at follow-up. IVUS examination was performed at 12 months. There were analyzed 34 cases (BiOSS Expert® 11 patients, BiOSS LIM® 23 patients). Procedural characteristics in the two groups were similar, except for rates of main vessel predilatation and FKB/POT, which were higher in BiOSS® LIM group, 54.5 % vs 73.9 % (P < 0.05) and 0 % vs 39.1 % (P < 0.05), respectively. When comparing late lumen loss (LLL) for both stents there were significantly bigger values for main vessel and main branch in the BiOSS® Expert group, but not in side branch. Intravascular ultrasound examination showed that in the BiOSS LIM® group comparing with the BiOSS Expert® group there was lower neointima burden in the whole stent (24.7 ± 7.5 % vs 19.4 ± 8.6 %, P < 0.05) as well as in main vessel (22.8 ± 5.6 % vs 16.9 ± 6.1 %, P < 0.05) and main branch (36.1 ± 6.5 % vs 27.6 ± 8.7 %, P < 0.05), but not at the level of bifurcation (15.1 ± 3.8 % vs 13.6 ± 5.4 %, P = NS). In addition, we found that final kissing balloon/proximal optimization technique (FKB/POT) was associated with significantly smaller value of LLL in main vessel (0.24 ± 0.09 mm vs 0.32 ± 0.14 mm, P < 0.05), which in IVUS analysis resulted in smaller neointima burden in main vessel (13.7 ± 3.9 % vs 18.9 ± 4.45 %, P < 0.05) as well as at the bifurcation site (12.6 ± 4.1 % vs 14.1 ± 2.4 %, P < 0.05). The obtained results suggest that neointima proliferation was the largest in main branches of both stents assessed in quantitative angiography (LLL) as well as in IVUS (neointima burden) and the neointima increase was smaller in BiOSS LIM® stents than in BiOSS Expert® stents. Moreover, the middle part of the stent seems to not to be associated with excessive neointima proliferation and more aggressive protocol of implantation with the use FKB/POT seems to decrease this process.
引用
收藏
页码:1339 / 1347
页数:8
相关论文
共 50 条
  • [31] Translating advice to eat more vegetables into practice: observations from a 12-month weight loss trial
    O'Shea, Jane
    Tapse, Linda
    Thorne, Rebecca
    Probst, Yasmine
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2019, 73 (05) : 801 - 804
  • [32] Translating advice to eat more vegetables into practice: observations from a 12-month weight loss trial
    Jane O’Shea
    Linda Tapsell
    Rebecca Thorne
    Yasmine Probst
    European Journal of Clinical Nutrition, 2019, 73 : 801 - 804
  • [33] Fracking compared to conventional balloon angioplasty alone for calcified common femoral artery lesions using intravascular ultrasound analysis: 12-month results
    Haraguchi, Takuya
    Fujita, Tsutomu
    Kashima, Yoshifumi
    Tsujimoto, Masanaga
    Otake, Ryo
    Kasai, Yuhei
    Sato, Katsuhiko
    CVIR ENDOVASCULAR, 2023, 6 (01)
  • [34] Fracking compared to conventional balloon angioplasty alone for calcified common femoral artery lesions using intravascular ultrasound analysis: 12-month results
    Takuya Haraguchi
    Tsutomu Fujita
    Yoshifumi Kashima
    Masanaga Tsujimoto
    Ryo Otake
    Yuhei Kasai
    Katsuhiko Sato
    CVIR Endovascular, 6
  • [35] Twelve-month intravascular ultrasound results from STEALTH-1: A randomized first in man trial of Biolimus A9 eluting stents
    Jegere, S
    Koizumi, T
    Yamasaki, M
    Shimada, Y
    Hassan, AHM
    Yock, PG
    Hauptmann, KE
    Grube, E
    Honda, G
    Abizaid, A
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 39B - 39B
  • [36] Regularity of treatment in nAMD: 12-month results of the PERSEUS and RAINBOW studies
    Framme, Carsten
    Kodjikian, Laurent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [37] CYPHER sirolimus-eluting coronary stent in chronic total occlusion (SICTO): 12-month clinical and 6-month angiographic and intravascular ultrasound follow-up.
    Lotan, C
    Almagor, Y
    Wijns, W
    Kuiper, K
    Suttorp, MJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 206E - 206E
  • [38] Cognitive performance and 12-month clinical outcome in first-episode of depression
    Vicent-Gil, M.
    Keymer-Gausset, A.
    Carceller-Sindreu, M.
    Serra-Blasco, M.
    De Diego-Adelino, J.
    Trujols, J.
    Perez, V.
    Alvarez, E.
    Cardoner, N.
    Portella, M. J.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2017, 27 : S795 - S796
  • [39] ABSORB EXTEND: An Interim Report on the 12-month Clinical Outcomes from the First 250 Patients Enrolled
    Bartorelli, Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B10 - B11
  • [40] Free Water Alterations in the First Episode Psychosis: A 12-Month Longitudinal Study
    Guo, Yu
    Lesh, Tyler
    Carter, Cameron
    BIOLOGICAL PSYCHIATRY, 2017, 81 (10) : S255 - S255