Irreversible three-heat-source refrigerator with heat transfer law of Qαδ(T -1) and its performance optimization based on ECOP criterion

被引:15
|
作者
Wouagfack P.A.N. [1 ]
Tchinda R. [2 ]
机构
[1] L2MSP, Department of Physics, University of Dschang, Dschang
[2] LISIE, University of Dschang, Bandjoun
关键词
Absorption refrigerator; Ecological coefficient of performance; Irreversible; Three-heat-source;
D O I
10.1007/s12667-011-0040-y
中图分类号
学科分类号
摘要
The new thermo-ecological optimization of an absorption system for cooling applications operating between three temperature levels with the linear phenomenological heat transfer law of Qαδ(T -1) has been performed by taking account the losses of heat resistance, internal irreversibility and leakage. The considered objective function is the ecological coefficient of performance (ECOP) and is defined as the cooling load per unit loss rate of availability. The comparative analysis with the ecological optimization criterion (E) defined in the literature and also with the cooling load optimization criterion (R) has been carried out to prove the utility of the new thermo-ecological optimization criterion (ECOP) for three-heat-source refrigerators with linear phenomenological heat transfer law. The results show that the three-heatsource refrigeration cycle working at maximum ECOP conditions has a significant advantage in terms of entropy production rate and coefficient of performance over the maximum E and maximum R conditions. The obtained results may provide a general theoretical tool for the thermo-ecological design of absorption refrigerator. © The Author(s) 2011.
引用
收藏
页码:359 / 376
页数:17
相关论文
共 27 条
  • [21] ETA-M FOR THE HEAT-TRANSFER LAW Q-ALPHA-DELTA-1/T
    YAN, ZJ
    CHEN, LX
    CHINESE SCIENCE BULLETIN, 1989, 34 (07): : 553 - 556
  • [22] Optimal configuration and performance for a generalized Carnot cycle assuming the heat-transfer law Q α (ΔT)m
    Chen, LG
    Zhu, XQ
    Sun, FR
    Wu, C
    APPLIED ENERGY, 2004, 78 (03) : 305 - 313
  • [23] Optimization study on the heat transfer area of the sewage source heat pump system based on year-round coefficient of performance
    Zhuang, Zhaoyi
    Li, Guitao
    Zhang, Yong
    Li, Yongbin
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1535 - 1543
  • [24] Design and performance simulation of a novel hybrid PV/T-air dual source heat pump system based on a three-fluid heat exchanger
    Zhang, Penglei
    Rong, Xingyue
    Yang, Xiaorui
    Zhang, Dalin
    SOLAR ENERGY, 2019, 191 : 505 - 517
  • [25] MINIMUM ENTROPY GENERATION PATH FOR LIGHT-DRIVEN ENGINE WITH [A](sic)[B] SYSTEM AND q ∝ Δ(T-1) HEAT TRANSFER LAW
    Chen, Lingen
    Ma, Kang
    Ge, Yanlin
    Sun, Fengrui
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2017, 16 (09): : 2035 - 2043
  • [26] Gyroid-type TPMS structure optimization based on mathematical function control and its convective heat transfer performance study
    Qin, Kaiwen
    Zhuang, Nailiang
    Shao, Chong
    Zhao, Hangbin
    Tang, Xiaobin
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 162
  • [27] Self-Supporting Microchannel Liquid-Cooled Plate for T/R Modules Based on Additive Manufacturing: Study on Its Pass Design, Formation Process and Boiling Heat Transfer Performance
    Qian, Bo
    Fan, Hongri
    Liu, Gang
    Zhang, Jianrui
    Li, Pei
    METALS, 2021, 11 (11)