A highly selective iodide electrode based on the bis(benzoin)-semiethylenediamine complex of mercury(II) as a carrier

被引:0
|
作者
You-Qun Song
R. Yuan
M. Ying
Zhi-Qiang Li
Y.-Q. Chai
H. Cui
G.-L. Shen
Ru-Qin Yu
机构
[1] Institute of Chemometrics and Chemical Sensing Technology,
[2] Chemistry and Chemical Engineering College,undefined
[3] Hunan University,undefined
[4] Changsha,undefined
[5] 410082,undefined
[6] China,undefined
关键词
Quartz; Mercury; Iodide; Linear Response; Quartz Crystal;
D O I
暂无
中图分类号
学科分类号
摘要
A new PVC membrane electrode based on the bis(benzoin)-semiethylenediamine (BBSEA) complex of Hg(II) is described which exhibits excellent selectivity towards iodide, related to the unique interaction between the central Hg(II) and the iodide ion. The electrode has a linear response to iodide from 5 × 10–7 to 5 × 10–4 mol/L with a slope of 58 mV/dec.(20°C). The response characteristics were investigated in detail and the mechanism of the electrode was studied with AC impedance and quartz crystal microbalance (QCM) techniques. It can be used for iodide determinations in drug preparations.
引用
收藏
页码:47 / 51
页数:4
相关论文
共 50 条
  • [21] Highly selective iodide poly(vinyl chloride) membrane electrode based on a nickel(II) tetraazaannulene macrocyclic complex
    Ying, M
    Yuan, R
    Zhang, XM
    Song, YQ
    Li, ZQ
    Shen, GL
    Yu, RQ
    ANALYST, 1997, 122 (10) : 1143 - 1146
  • [22] Perchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier
    Rezaei, Behzad
    Meghdadi, Soraia
    Bagherpour, Saeid
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (2-3) : 641 - 648
  • [23] Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex
    Benvidi, Ali
    Ghanbarzadeh, M. T.
    Mazloum-Ardakani, Mohammad
    Vafazadeh, R.
    CHINESE CHEMICAL LETTERS, 2011, 22 (09) : 1087 - 1090
  • [24] MERCURY(II) POTENTIOMETRIC TITRATIONS USING AN IODIDE-SELECTIVE ELECTRODE
    BERNAL, JL
    PARDO, R
    DELNOZAL, MJ
    ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1983, 79 (02): : 305 - 308
  • [25] Copper(I)-bathocuproine complex as carrier in iodide-selective electrode
    Pouretedal, HR
    Keshavarz, MH
    TALANTA, 2004, 62 (01) : 223 - 227
  • [26] Highly Selective Potentiometric Iodide Ion Sensors Based on Bis-(o-phenylenediamine)Cu(II) Complex
    Rawat, Aruna
    Chandra, Sulekh
    Sarkar, Anjana
    SENSOR LETTERS, 2010, 8 (06) : 753 - 759
  • [27] An ion selective electrode for mercury(II) based on mercury(II) complex of poly(4-vinyl pyridine)
    Bakhtiarzadeh, Fariba
    Ab Ghani, Sulaiman
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 624 (1-2) : 139 - 143
  • [28] Fast response and selective perchlorate polymeric membrane electrode based on bis(dibenzoylmethanato) nickel(II) complex as a neutral carrier
    Rezaei, B.
    Meghdadi, S.
    Nafisi, V.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) : 600 - 605
  • [29] Tricoordinate Schiff base copper(II) complex as neutral carrier for highly selective thiocyanate electrode
    Dai, JY
    Chai, YQ
    Yuan, R
    An, LX
    Liu, Y
    Zhong, X
    Tang, DP
    ANALYTICAL LETTERS, 2005, 38 (03) : 389 - 400
  • [30] Highly selective salicylate membrane electrode based on N,N′-(aminoethyl)ethylenediamide bis(2-salicylideneimine) binuclear copper(II) complex as neutral carrier
    Sun Ai-Li
    Chai Ya-Qin
    Yuan Ruo
    Gui Guo-Feng
    CHINESE JOURNAL OF CHEMISTRY, 2006, 24 (07) : 894 - 898