A magnetic bead-based DNA extraction and purification microfluidic device

被引:0
|
作者
Sayyed Mohamad Azimi
Gavin Nixon
Jeremy Ahern
Wamadewa Balachandran
机构
[1] Brunel University,School of Engineering & Design
[2] Massachusetts Institute of Technology (MIT),Department of Electrical Engineering and Computer Science
[3] LGC,undefined
来源
关键词
Magnetic beads; Magnetic mixing; DNA extraction; Microfluidic chip; Solid-phase extraction;
D O I
暂无
中图分类号
学科分类号
摘要
This article introduces a novel magnetic bead-based DNA extraction and purification device using active magnetic mixing approach. Mixing and separation steps are performed using functionalised superparamagnetic beads suspended in cell lysis buffer in a circular chamber that is sandwiched between two external magnetic coils. Non-uniform nature of magnetic field causes temporal and spatial distribution of beads within the chamber. This process efficiently mixes the lysis buffer and whole blood in order to extract DNA from target cells. Functionalized surface of the magnetic beads then attract the exposed DNA molecules. Finally, DNA-attached magnetic beads are attracted to the bottom of the chamber by activating the bottom magnetic coil. DNA molecules are extracted from magnetic beads by washing and re-suspension processes. In this study, a circular PMMA microchamber, 25 μL in volume, 500 μm in depth and 8 mm in diameter was fabricated to purify DNA from spiked bacterial cell cultures into the whole blood sample using Promega Magazorb DNA extraction kit. The lysis efficiency was evaluated using a panel of Gram-positive (Bacillus subtilis) and Gram-negative (Escherichia coli) bacterial cells cultures into the blood sample to achieve approximately 100,000 copy levels inside the chip. Manufacturer’s standard extraction protocol was modified to a more simplified process suitable for chip-based extraction. The lysis step was performed using 5 min incubation at 56 °C followed by 5 min incubation at room temperature for binding process. Temperature rise was generated and maintained by the same external magnetic coils used for active mixing. The yield/purity and recovery levels of the extracted DNA were evaluated using quantitative UV spectrophotometer and real-time PCR assay, respectively. Real-time PCR results indicated efficient chip-based bacterial DNA extraction using modified extraction protocol comparable to the standard bench-top extraction process.
引用
收藏
页码:157 / 165
页数:8
相关论文
共 50 条
  • [21] Assessment of direct versus indirect magnetic bead-based T-cell isolation procedures followed by magnetic bead-based DNA isolation
    Rosenbaum, Anna
    Bleck, Ellen
    Schneider, Matthias
    Pongratz, Georg
    Vordenbaumen, Stefan
    LUPUS SCIENCE & MEDICINE, 2016, 3 (01):
  • [22] Evaluation of a Partially-automated Magnetic Bead-based Method for DNA Extraction for Wheat and Barley MAS
    Czembor, P. Cz.
    Sejbuk, K.
    Kleszcz, R.
    CEREAL RESEARCH COMMUNICATIONS, 2014, 42 (01) : 27 - 37
  • [23] Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples
    Witt, Sebastian
    Neumann, Jan
    Zierdt, Holger
    Gebel, Gabriella
    Roescheisen, Christiane
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2012, 6 (05) : 539 - 547
  • [24] Evaluation of a Partially-automated Magnetic Bead-based Method for DNA Extraction for Wheat and Barley MAS
    P. Cz. Czembor
    K. Sejbuk
    R. Kleszcz
    Cereal Research Communications, 2014, 42 : 27 - 37
  • [25] Magnetic bead-based sample preparation
    Lamberg, Arja
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2007, 27 (12): : 26 - 27
  • [26] Magnetic bead-based electrochemical assay for determination of DNA methyltransferase activity
    Dudova, Zdenka
    Bartosik, Martin
    Fojta, Miroslav
    ELECTROCHIMICA ACTA, 2017, 231 : 575 - 581
  • [27] ROLLING CIRCLE AMPLIFICATION IN BEAD-BASED MICROFLUIDIC DEVICE WITH INTEGRATED PHOTODIODE FOR FLUORESCENCE SIGNAL TRANSDUCTION
    Caneira, Catarina R. F.
    Soares, Ruben R. G.
    Nikolaidou, Katerina
    Nilsson, Mats
    Madaboosi, Narayanan
    Chu, Virginia
    Conde, Joao P.
    2021 34TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2021), 2021, : 575 - 578
  • [28] Integrated microfluidic chip for cell culture and stimulation and magnetic bead-based biomarker detection
    Ruffert, Christine
    Ramadan, Qasem
    Ruegg, Matthieu
    Vergères, Guy
    Gijs, Martin A. M.
    Micro and Nanosystems, 2014, 6 (01) : 61 - 68
  • [29] Regenerable bead-based microfluidic device with integrated thin-film photodiodes for real-time monitoring of DNA detection
    Caneira, Catarina R. F.
    Santos, Denis R.
    Chu, Virginia
    Conde, Joao P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 359
  • [30] An integrated microfluidic biochemical detection system with magnetic bead-based sampling and analysis capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, : 447 - 450