Skewness-based characterization of silicon photomultipliers

被引:0
|
作者
S. Vinogradov
机构
[1] P.N. Lebedev Physical Institute of the Russian Academy of Sciences,
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Characterization of SiPMs is an objective of high importance in almost any research, development, and application of these unique photon detectors. Two decades of characterization method developments resulted in a comprehensive and elegant methodology based on a precisely resolved number of fired SiPM cells or the SiPM spectrum. Spectrum fitting procedures are very sensitive to a proper selection of many initial guess values including parameters of minor importance and happen to be unreliable. Moreover, conventional methods are useless for degraded or unresolved SiPM spectra. This challenge was anticipated for SiPM-based detectors of high-luminosity particle calorimeters where a severe radiation degradation of the SiPMs would co-exist with their acceptable performance. To address it, one can measure a mean and variance of SiPM charge responses relying on a priori known Excess Noise Factor of the SiPM but its stability during SiPM degradation is uncertain. This study proposes and evaluates a new approach for the SiPM characterization based on the first three statistical moments (mean, variance, and skewness) of its charge response including skewness. It assumes the Generalized Poisson distribution of the number of fired cells and provides simple closed-form analytical expressions for the parameter estimation. It allows determining a gain, a number of detected photons, and a probability of correlated events directly from raw data. The skewness-based characterization is anticipated to be especially useful for mass testing and continuous monitoring of SiPMs in large-scale experiments due to its simplicity and robustness. Initial evaluations of the method show promising results.
引用
收藏
相关论文
共 50 条
  • [31] Silicon photomultipliers characterization for the EMR prototype of the MICE experiment
    Berra, A.
    Bolognini, D.
    Bonvicinie, V.
    Cauz, D.
    Driutti, A.
    Giannini, G.
    Hasan, S.
    Iugovaz, D.
    Lietti, D.
    Mascagna, V.
    Mattera, A.
    Pauletta, G.
    Penzo, A.
    Prest, M.
    Rashevskaya, I.
    Reia, S.
    Vallazza, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 129 - 135
  • [32] A Skewness-Based Harmonic Filter for Harmonic Attenuation of Wearable Functional Near-Infrared Spectroscopy Signals
    Ferdinando, Hany
    Ilvesmaki, Martti
    Kananen, Janne
    Moradi, Sadegh
    Myllyla, Teemu
    DIGITAL HEALTH AND WIRELESS SOLUTIONS, PT II, NCDHWS 2024, 2024, 2084 : 155 - 167
  • [33] Rapid characterization of silicon photomultipliers for noble liquid experiments
    Chana, B.
    Mahtab, M.
    Retiere, F.
    Viel, S.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [34] Characterization and modeling of crosstalk and afterpulsing in Hamamatsu silicon photomultipliers
    Rosado, J.
    Hidalgo, S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [35] Characterization of silicon photomultipliers for their application in muon scattering tomography
    Sun, Binghao
    Li, Huiling
    Li, Quanyin
    Liang, Hui
    Liu, Cong
    Wang, Hongbo
    Wu, Zibing
    Xiao, Suyu
    Xu, Weiwei
    JOURNAL OF INSTRUMENTATION, 2025, 20 (02):
  • [36] Time and charge characterization of Hamamatsu Photonics silicon photomultipliers
    Galetta, G.
    Ciciriello, F.
    Corsi, F.
    De Leo, R.
    Garibaldi, F.
    Lagamba, L.
    Licciulli, F.
    Loddo, F.
    Marzocca, C.
    Nappi, E.
    Perrino, R.
    Ranieri, A.
    INPC 2013 - INTERNATIONAL NUCLEAR PHYSICS CONFERENCE, VOL. 2, 2014, 66
  • [37] Epileptic Tissue Localization through Skewness-Based Functional Connectivity in the High-Frequency Band of Intracranial EEG
    Shen, Mu
    Zhang, Lin
    Gong, Yi
    Li, Lei
    Liu, Xianzeng
    BIOENGINEERING-BASEL, 2023, 10 (04):
  • [38] Characterization and Optimization of silicon photomultipliers for the development of intraoperative beta probes
    Hudin, N.
    Pinot, L.
    Dinu, N.
    Charon, Y.
    Puill, V.
    Janvier, B.
    Chaumat, V.
    Duval, M. -A.
    Haidar, D. Abi
    Siebert, R.
    Menard, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 242 - 246
  • [39] Characterization of linearly graded position-sensitive silicon photomultipliers
    Alessandro Ferri
    Fabio Acerbi
    Alberto Gola
    Giovanni Paternoster
    Claudio Piemonte
    Nicola Zorzi
    EJNMMI Physics, 1 (Suppl 1)
  • [40] Application of ultrashort laser pulses for timing characterization of silicon photomultipliers
    Popova, E. V.
    Buzhan, P. Zh
    Stifutkin, A. A.
    Ilyin, A. L.
    Mavritskii, O. B.
    Egorov, A. N.
    Nastulyavichius, A. A.
    V INTERNATIONAL CONFERENCE OF PHOTONICS AND INFORMATION OPTICS, 2016, 737