Seismic performance assessment and base-isolated floor protection of statues exhibited in museum halls

被引:0
|
作者
Stefano Sorace
Gloria Terenzi
机构
[1] University of Udine,Department of Civil Engineering and Architecture
[2] University of Florence,Department of Civil and Environmental Engineering
来源
关键词
Statues; Seismic assessment; Seismic performance levels; Smeared-crack models; Incremental dynamic analysis; Base isolation;
D O I
暂无
中图分类号
学科分类号
摘要
A study concerning the evaluation of seismic response of statues exhibited in art museums, and a base-isolated floor strategy for their enhanced protection, are presented in this paper. Attention is particularly focused on statues made of small tensile strength materials, whose behaviour is simulated by a smeared-crack finite element approach. Seismic performance is assessed by referring to four levels specially postulated herein, and namely: (1) Rest conditions; (2) No rocking; (3) Damage control; and (4) Collapse prevention. The response is investigated via incremental dynamic analysis, by progressively increasing the amplitude of the ground motion histories adopted as inputs, and by relating output data to the limit conditions fixed for the above-mentioned performance levels. The assessment procedure is applied to a demonstrative case study, represented by a marble statue to be exhibited in the museum wing situated at the ground level of a medieval castle in Italy, according to an architectural hypothesis of partial rebuilding and reuse of the stronghold. The design solution for the base-isolated floor consists in a system of double-friction pendulum isolators. The finite element model constitutive laws and parameters, the dynamic analyses carried out in fixed-base and base-isolated floor conditions, and the practical implementation of the assumed performance assessment criteria are reported for the statue examined, along with a selection of technical details of the floor design.
引用
收藏
页码:1873 / 1892
页数:19
相关论文
共 50 条
  • [21] Probabilistic seismic performance assessment of base-isolated buildings incorporating SMA gap dampers for pounding mitigation
    Yu, Tianhao
    Wang, Bin
    Chen, Peng
    Karavasilis, Theodore L.
    ENGINEERING STRUCTURES, 2025, 333
  • [22] Dynamics of seismic impacts in base-isolated buildings
    Malhotra, P.K.
    Earthquake Engineering and Structural Dynamics, 1997, 26 (08): : 797 - 813
  • [23] STOCHASTIC SEISMIC RESPONSE OF BASE-ISOLATED BUILDINGS
    Jacob, C.
    Sepahvand, K.
    Matsagar, V. A.
    Marburg, S.
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2013, 5 (01)
  • [24] Experimental seismic evaluation of base-isolated transformers
    Ersoy, S
    Saadeghvaziri, MA
    Liu, GY
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 561 - 566
  • [25] Seismic behavior of rocking base-isolated structures
    Cheng, Chin -Tung
    Chao, Chih-Hung
    ENGINEERING STRUCTURES, 2017, 139 : 46 - 58
  • [26] Seismic Response Mitigation of Base-Isolated Buildings
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Rupakhety, Rajesh
    APPLIED SCIENCES-BASEL, 2020, 10 (04):
  • [27] Dynamics of seismic impacts in base-isolated buildings
    Malhotra, PK
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1997, 26 (08): : 797 - 813
  • [28] Floor design response spectrum of base-isolated structure
    Dang Y.
    Li G.
    Xie P.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (07): : 321 - 332
  • [29] FLOOR RESPONSE SPECTRA FOR BASE-ISOLATED MULTISTORY STRUCTURES
    FAN, FG
    AHMADI, G
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1990, 19 (03): : 377 - 388
  • [30] Seismic protection of base-isolated structures using semi-active MR dampers
    Tse, T
    Chang, CC
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 529 - 536