Evaluation of a new fluorescence-based device in the detection of incipient occlusal caries lesions

被引:0
|
作者
Eva-Eleni Achilleos
Christos Rahiotis
Afrodite Kakaboura
George Vougiouklakis
机构
[1] University of Athens (NKUA),
[2] University of Athens (NKUA),undefined
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Caries detection methods; Fluorescence; DIAGNOdent pen; ICDAS; Caries detection;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this in vitro study was to evaluate the performance of various contemporary detection tools at incipient occlusal caries. Thirty eight freshly extracted posterior teeth with non-cavitated occlusal caries were subjected to clinical examination and coding according to ICDAS criteria (n = 38). Standardized fluorescence images were taken with VistaProof (Dürr Dental, Bietigheim-Bissingen, Germany). Furthermore, the teeth were calculated with a laser fluorescence pen device (DIAGNOdent pen, Kavo, Biberach, Germany). In all detection methods, assessment of caries was performed twice (with 1-week interval) by two calibrated examiners. Finally, the caries lesions were validated in tooth sections by histological examination. The intra-examiner and inter-examiner kappa coefficient, sensitivity, and specificity were determined for all detection methods at enamel lesions (D1 threshold). Degrees of agreement of each method with the histological status were calculated using receiver operating characteristic statistics and the area under curve (Az values). The kappa intra-examiner/inter-examiner coefficient values (mean ± SD) were 0.74 ± 0.04/0.73 ± 0.07, 0.87 ± 0.04/0.82 ± 0.07, and 0.91 ± 0.06/0.83 ± 0.08 for clinical examination, DIAGNOdent pen, and VistaProof, respectively. The sensitivity for ICDAS was 0.80–0.86, for DIAGNOdent pen was 0.66–0.75, and for the VistaProof device was 0.97. The specificity for all the detection methods were 0.5 (0.02–0.99). The accuracy value for ICDAS was 0.76–0.81, for DIAGNOdent pen 0.66–0.71, and for the VistaProof device 0.92–0.95. The Az values (mean ± SD) were 0.431 ± 0.187, 0.583 ± 0.215, and 0.486 ± 0.207 for ICDAS, DIAGNOdent pen, and VistaProof examination, respectively. No significant differences in Az values were noted among the methods. All detection methods were presented with high inter-examiner and intra-examiner agreement. The new VistaProof device showed the best sensitivity, while DIAGNOdent pen demonstrated the worst one. Specificities were the same for all detection methods. Moreover, they presented the same performance in detection of incipient occlusal caries.
引用
收藏
页码:193 / 201
页数:8
相关论文
共 50 条
  • [31] Performance of a fluorescence camera for detection of occlusal caries in vitro
    Anahita Jablonski-Momeni
    Helge Marten Schipper
    Simon Martin Rosen
    Monika Heinzel-Gutenbrunner
    Matthias Johannes Roggendorf
    Richard Stoll
    Vitus Stachniss
    Klaus Pieper
    Odontology, 2011, 99 : 55 - 61
  • [32] Evaluation of the effectiveness of laser fluorescence in monitoring in vitro remineralization of incipient caries lesions in primary teeth
    Mendes, FM
    Nicolau, J
    Duarte, DA
    CARIES RESEARCH, 2003, 37 (06) : 442 - 444
  • [33] Detection of nosocomial pneumonia pathogens using a fluorescence-based device
    Jung, Eun-Ha
    Yang, Ji-Hye
    Mun, So-Jung
    Han, Sun-Young
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 37
  • [34] Fluorescence-Based Bioassays for the Detection and Evaluation of Food Materials
    Nishi, Kentaro
    Isobe, Shin-Ichiro
    Zhu, Yun
    Kiyama, Ryoiti
    SENSORS, 2015, 15 (10) : 25831 - 25867
  • [35] In vitro evaluation of the influence of air abrasion on detection of occlusal caries lesions in primary teeth
    Rodrigues, Jonas de Almeida
    de Vita, Thais Maria
    Loiola Cordeiro, Rita de Cassia
    PEDIATRIC DENTISTRY, 2008, 30 (01) : 15 - 18
  • [36] Performance of a recent light fluorescence device for detection of occlusal carious lesions in children and adolescents
    Muller-Bolla M.
    Joseph C.
    Pisapia M.
    Tramini P.
    Velly A.M.
    Tassery H.
    European Archives of Paediatric Dentistry, 2017, 18 (3) : 187 - 195
  • [37] Study of validity of autofluorescence-based incipient occlusal caries detection in vitro compared to DIAGNOdent pen
    Zhu, H. H.
    Chen, Q. G.
    Lin, B.
    Chen, H.
    LASER PHYSICS, 2012, 22 (03) : 614 - 619
  • [38] Direct detection of organophosphate compounds in water by a fluorescence-based biosensing device
    Carullo, Paola
    Chino, Marco
    Cetrangolo, Giovanni Paolo
    Terreri, Sara
    Lombardi, Angela
    Manco, Giuseppe
    Cimmino, Amelia
    Febbraio, Ferdinando
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 3257 - 3266
  • [39] Correlation between Laser Fluorescence Readings and Volume of Tooth Preparation in Incipient Occlusal Caries In Vitro
    Ghaname, Eduardo S.
    Ritter, Andre V.
    Heymann, Harald O.
    Vann, William F., Jr.
    Shugars, Daniel A.
    Bader, James D.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2010, 22 (01) : 31 - 39
  • [40] Fluorescence-based mutation detection
    Ellison, JS
    MOLECULAR BIOTECHNOLOGY, 1996, 5 (01) : 17 - 31