Chest compression-associated injuries in cardiac arrest patients treated with manual chest compressions versus automated chest compression devices (LUCAS II) – a forensic autopsy-based comparison

被引:0
|
作者
Benjamin Ondruschka
Christina Baier
Ronny Bayer
Niels Hammer
Jan Dreßler
Michael Bernhard
机构
[1] Institute of Legal Medicine,Department of Anatomy
[2] University of Leipzig,Emergency Department
[3] University of Otago,undefined
[4] Heinrich Heine University,undefined
[5] University Hospital,undefined
关键词
Automated chest compression devices; Cardiopulmonary resuscitation; Forensic autopsy; Injury frequency; Manual chest compression; Rib fractures;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this autopsy study was to investigate chest-compression associated injuries to the trunk in out-of-hospital and in-hospital non-traumatic cardiac arrest patients treated with automated external chest compression devices (ACCD; all with LUCAS II devices) versus exclusive manual chest compressions (mCC). In this retrospective single-center study, all forensic autopsies between 2011 and 2017 were included. Injuries following cardiopulmonary resuscitation (CPR) in patients treated with mCC or ACCD were investigated and statistically compared using a bivariate logistic regression. In the seven-year period with 4433 autopsies, 614 were analyzed following CPR (mCC vs. ACCD: n = 501 vs. n = 113). The presence of any type of trunk injury was correlated with longer resuscitation intervals (30 ± 15 vs. 44 ± 25 min, p < 0.05). In comparison with mCC, treatment with ACCD led to more frequent skin emphysema (5 vs 0%, p = 0.012), pneumothorax (6 vs. 1%, p = 0.008), lung lesions (19 vs. 4%, p = 0.008), hemopericardium (3 vs 1%, p = 0.025) and liver lesions (10 vs. 1%, p = 0.001), all irrespective of confounding aspects. Higher age and longer CPR durations statistically influenced frequency of sternal and rib fractures (p < 0.001). The mean number of fractured ribs did not vary significantly between the groups (6 ± 3 vs. 7 ± 2, p = 0.09). In this cohort with unsuccessful CPR, chest compression-related injuries were more frequent following ACCD application than in the mCC group, but with only minutely increased odds ratios. The severity of injuries did not differ between the groups, and no iatrogenic injury was declared by the forensic pathologist as being fatal. In the clinical routine after successful return of spontaneous circulation a computed tomography scan for CPR-associated injuries is recommended as soon as possible.
引用
收藏
页码:515 / 525
页数:10
相关论文
共 50 条
  • [21] A case of hypothermic cardiac arrest treated with an external chest compression device (LUCAS) during transport to re-warming
    Holmström, P
    Boyd, J
    Sorsa, M
    Kuisma, M
    RESUSCITATION, 2005, 67 (01) : 139 - 141
  • [22] Comparison of Sustained Return of Spontaneous Circulation Rate Between Manual and Mechanical Chest Compression in Adult Cardiac Arrest
    Tantarattanapong, Siriwimon
    Chantaramanee, Kwanchanok
    OPEN ACCESS EMERGENCY MEDICINE, 2022, 14 : 599 - 608
  • [23] Web-based general public opinion study of automated versus manual external chest compression
    Lapostolle, Frederic
    Bertrand, Philippe
    Agostinucci, Jean-Marc
    Pradeau, Catherine
    Tazarourte, Karim
    Grave, Melanie
    Galinski, Michel
    Adnet, Frederic
    EMERGENCY MEDICINE JOURNAL, 2014, 31 (06) : 488 - 492
  • [24] The comparison the artifact by the usual electrocardiogram versus the dynamic monitorlizer (Radarcirc™) during chest compressions of cardiac arrest patients
    Shimpuku, Genji
    CIRCULATION, 2007, 116 (16) : 946 - 946
  • [25] Optimal position for external chest compression during cardiopulmonary resuscitation: an analysis based on chest CT in patients resuscitated from cardiac arrest
    Cha, Kyoung Chul
    Kim, Yeong Jun
    Shin, Hyung Jin
    Cha, Yong Sung
    Kim, Hyun
    Lee, Kang Hyun
    Kwon, Woocheol
    Hwang, Sung Oh
    EMERGENCY MEDICINE JOURNAL, 2013, 30 (08) : 615 - 619
  • [26] Out-of-hospital airway management during manual compression or automated chest compression devices. A registry-based analysis
    Bernhard, M.
    Behrens, N. H.
    Wnent, J.
    Seewald, S.
    Brenner, S.
    Jantzen, T.
    Bohn, A.
    Graesner, J. T.
    Fischer, M.
    ANAESTHESIST, 2018, 67 (02): : 109 - 117
  • [27] The Relationship Between Duration of Chest Compression and Traumatic Thoracic Injuries in Out-of-hospital Cardiac Arrest Patients
    Katasako, Aya
    Kawakami, Shoji
    Ikee, Takashi
    Shojima, Yoko
    Maezono, Akihiro
    Furukawa, Shoichiro
    Oga, Yasuhiro
    Takahara, Yusuke
    Inanaga, Keita
    Imamura, Yoshihiro
    Yamada, Tetsuhisa
    Miura, Nobutoshi
    Inoue, Shujiro
    CIRCULATION, 2020, 142
  • [28] Automated mechanical cardiopulmonary resuscitation devices versus manual chest compressions in the treatment of cardiac arrest: protocol of a systematic review and meta-analysis comparing machine to human
    Obermaier, Manuel
    Zimmermann, Johannes B.
    Popp, Erik
    Weigand, Markus A.
    Weiterer, Sebastian
    Dinse-Lambracht, Alexander
    Muth, Claus-Martin
    Nussbaum, Benedikt L.
    Graesner, Jan-Thorsten
    Seewald, Stephan
    Jensen, Katrin
    Seide, Svenja E.
    BMJ OPEN, 2021, 11 (02):
  • [29] A meta-analysis of the resuscitative effects of mechanical and manual chest compression in out-of-hospital cardiac arrest patients
    Zhu, Ni
    Chen, Qi
    Jiang, Zhixia
    Liao, Futuan
    Kou, Bujin
    Tang, Hui
    Zhou, Manhong
    CRITICAL CARE, 2019, 23
  • [30] A meta-analysis of the resuscitative effects of mechanical and manual chest compression in out-of-hospital cardiac arrest patients
    Ni Zhu
    Qi Chen
    Zhixia Jiang
    Futuan Liao
    Bujin Kou
    Hui Tang
    Manhong Zhou
    Critical Care, 23