Analysis of shade, temperature and hydrogen peroxide concentration during dental bleaching: in vitro study with the KTP and diode lasers

被引:0
|
作者
C. Fornaini
G. Lagori
E. Merigo
M. Meleti
M. Manfredi
R. Guidotti
A. Serraj
P. Vescovi
机构
[1] University of Parma,Oral Medicine and Laser
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Dental bleaching; Laser; Hydrogen peroxide; KTP; Diode;
D O I
暂无
中图分类号
学科分类号
摘要
Many dental bleaching techniques are now available, several of them using a laser source. However, the literature on the exact role of coherent light in the biochemical reaction of the whitening process is very discordant. The aims of this in vitro study were: (1) to compare two different laser sources, a KTP laser with a wavelength of 532 nm and a diode laser with a wavelength of 808 nm, during dental bleaching, and (2) to investigate the relationships among changes in gel temperature, tooth shade and hydrogen peroxide (HP) concentration during laser irradiation. Altogether, 116 bovine teeth were bleached using a 30% HP gel, some of them with gel only and others with gel plus one of the two lasers (532 or 808 nm) at two different powers (2 and 4 W). The KTP laser produced a significant shade variation with a minimal temperature increase. The diode laser led to a higher temperature increase with a greater reduction in HP concentration, but the change in shade was only statistically significant with a power of 4 W. At a power of 2 W, the KTP laser caused a greater change in shade than the diode laser. No significant correlations were found among temperature, HP concentration and shade variation. The KTP laser appears to provide better results with less dangerous thermal increases than the diode laser. This might call into question most of the literature affirming that the action of laser bleaching is by increasing the gel temperature and, consequently, the speed of the redox reaction. Further study is required to investigate the correlations between the parameters investigated and efficacy of the bleaching process.
引用
收藏
页码:1 / 6
页数:5
相关论文
共 50 条
  • [11] Assessment of the effect of experimental gel of pregabalin associated with 35% hydrogen peroxide bleaching on bovine dental enamel: an in vitro study
    Xavier, Gabriela Monteiro Barbosa
    Gil, Giovana Sholheid
    Paes, Yngrid Fernanda Oliveira
    Ferreira, Lindalva Maria de Meneses Costa
    Silva, Cecy Martins
    Ribeiro-Costa, Roseane Maria
    Araujo, Jesuina Lamartine Nogueira
    ODONTOLOGY, 2025, 113 (01) : 331 - 339
  • [12] Surface and pulp chamber temperature rises during tooth bleaching using a diode laser:: a study in vitro
    Sulieman, M.
    Rees, J. S.
    Addy, M.
    BRITISH DENTAL JOURNAL, 2006, 200 (11) : 631 - 634
  • [13] Surface and pulp chamber temperature rises during tooth bleaching using a diode laser: a study in vitro
    M Sulieman
    J S Rees
    M Addy
    British Dental Journal, 2006, 200 : 631 - 634
  • [14] Violet LED associated with high concentration hydrogen peroxide: Effects on bleaching efficacy, pH, and temperature
    Manzoli, Tatiane Miranda
    Costa, Joatan Lucas de Sousa Gomes
    Besegato, Joao Felipe
    Gelio, Mariana Bena
    Galvani, Lucas David
    Bordini, Ester Alves Ferreira
    Kuga, Milton Carlos
    Dantas, Andrea Abi Rached
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 40
  • [15] Comparative study of intrapulpal temperature stress during Er,Cr:YSGG-supported dental bleaching versus conventional dental power bleaching. An in vitro study
    Strakas D.
    Tolidis K.
    Koliniotou-Koumpia E.
    Vanweersch L.
    Franzen R.
    Gutknecht N.
    Lasers in Dental Science, 2017, 1 (2-4) : 57 - 64
  • [16] Hydrogen Peroxide Diffusion through Dental Tissues-In Vitro Study
    Dias, Susana
    Casqueiro, Leonor
    Pereira, Ruben
    Silveira, Joao
    Mata, Antonio
    Marques, Duarte
    MATERIALS, 2023, 16 (16)
  • [17] The bleaching depth of a 35% hydrogen peroxide based in-office product: a study in vitro
    Sulieman, M
    Addy, M
    Macdonald, E
    Rees, JS
    JOURNAL OF DENTISTRY, 2005, 33 (01) : 33 - 40
  • [18] Effects on gastric mucosa induced by dental bleaching - an experimental study with 6% hydrogen peroxide in rats
    Paula, Anabela Baptista
    Dias, Maria Isabel
    Ferreira, Manuel Marques
    Carrilho, Teresa
    Marto, Carlos Miguel
    Casalta, Joao
    Cabrita, Antonio Silverio
    Carrilho, Eunice
    JOURNAL OF APPLIED ORAL SCIENCE, 2015, 23 (05) : 497 - 507
  • [19] The Effect of 10% Carbamide Peroxide Dental Bleaching on the Physical Properties of Invisalign Aligners: An In Vitro Study
    Khashashneh, Majd
    Ratnayake, Jithendra
    Choi, Joanne Jung Eun
    Mei, Li
    Lyons, Karl
    Brunton, Paul
    MATERIALS, 2023, 16 (11)
  • [20] A Preliminary In Vitro Study on the Efficacy of High-Power Photodynamic Therapy (HLLT): Comparison between Pulsed Diode Lasers and Superpulsed Diode Lasers and Impact of Hydrogen Peroxide with Controlled Stabilization
    Caccianiga, Gianluigi
    Baldoni, Marco
    Ghisalberti, Carlo Angelo
    Paiusco, Alessio
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016