Voltammetric determination of phentolamine mesylate in pharmaceutical formulations at poly (4-aminobenzene sulfonic acid)-modified glassy carbon electrode

被引:0
|
作者
Sen Fan
Lei Ji
Guoliang Mao
Xin Sui
Huan Wang
Yuanhai Zhu
Hua Song
机构
[1] Northeast Petroleum University,College of Petroleum Engineering
[2] Northeast Petroleum University,College of Chemistry and Chemical Engineering
来源
Chemical Papers | 2020年 / 74卷
关键词
Phentolamine; Electropolymerization; 4-Aminobenzene sulfonic acid; Modified glassy carbon electrode;
D O I
暂无
中图分类号
学科分类号
摘要
A poly (4-aminobenzene sulfonic acid)-modified glassy carbon electrode (p-ABSA/GCE) was fabricated by electropolymerization. It was found that phentolamine mesylate, an effective and important cardiovascular dilatation drug with low redox activity at the glassy carbon electrode (GCE) can produce a sensitive well-defined anodic peak current at p-ABSA/GCE. Investigation indicated that the oxidation of phentolamine at p-ABSA/GCE was one electron/one proton transfer process which was controlled by adsorption. In optimal conditions, the anodic peak current was linear to the concentrations of phentolamine over the range of 5.0 × 10–7–1.0 × 10–5 M with a detection limit of 2.0 × 10–7 M. The modified electrode showed good stability and reproducibility. The electroanalytical method proposed was successfully applied to the determination of phentolamine mesylate in pharmaceutical formulations.
引用
收藏
页码:4411 / 4417
页数:6
相关论文
共 50 条
  • [21] Electrochemical Investigation of Isoniazid on Poly (p-Aminobenzene Sulfonic Acid) Film Modified Glassy Carbon Electrode
    Demirbilek, Esra
    Saglikoglu, Gulsen
    Yilmaz, Selehattin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (05): : 4428 - 4438
  • [22] Electrocatalytic Oxidation of Acyclovir on Poly(p-Aminobenzene Sulfonic Acid) Film Modified Glassy Carbon Electrode
    Can, Saide
    Yilmaz, Selehattin
    Saglikoglu, Gulsen
    Sadikoglu, Murat
    Menek, Necati
    ELECTROANALYSIS, 2015, 27 (10) : 2431 - 2438
  • [23] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF THEOPHYLLINE AT POLY(4-AMINO-3-HYDROXYNAPHTHALENE SULFONIC ACID) MODIFIED GLASSY CARBON ELECTRODE
    Amare, Meareg
    Admassie, Shimelis
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2012, 26 (01) : 73 - 84
  • [24] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Nhi, Le Thi Thanh
    Tu, Nguyen Thi Thanh
    Hoa, Le Thi
    Toan, Tran Thanh Tam
    Van Thanh Son, Le
    Van Hung, Nguyen
    Tuyen, Tran Ngoc
    Khieu, Dinh Quang
    JOURNAL OF NANOPARTICLE RESEARCH, 2021, 23 (10)
  • [25] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Le Thi Thanh Nhi
    Nguyen Thi Thanh Tu
    Le Thi Hoa
    Tran Thanh Tam Toan
    Le Van Thanh Son
    Nguyen Van Hung
    Tran Ngoc Tuyen
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2021, 23
  • [26] Poly-(p-aminobenzene sulfonic acid) modified glassy carbon electrode for selective determination of hydroquinone in the presence of catechol and resorcinol
    Yang, Zhousheng
    Hu, Guangzhi
    Liu, Yunchun
    Zhao, Jun
    Zhao, Guangchao
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2007, 52 (01): : 11 - 17
  • [27] A Sensor for Dopamine Based on Gold Nanoparticles/Poly(p-aminobenzene sulfonic acid) Modified Glassy Carbon Electrode
    Fang, Ying
    Liu, Yunchun
    Shen, Dongdong
    Li, Peng
    Yang, Zhousheng
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2015, 7 (06) : 462 - 468
  • [28] Poly(para amino benzene sulfonic acid) Modified Glassy Carbon Electrode for the Simultaneous as well as Individual Voltammetric Determination of Guanine, Adenine and Uric Acid
    Jesny, S.
    Kumar, K. Girish
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (14) : B720 - B726
  • [29] Voltammetric determination of uric acid using multiwall carbon nanotubes coated-poly(4-amino-3-hydroxy naphthalene sulfonic acid) modified glassy carbon electrode
    Tefera, Molla
    Tessema, Merid
    Admassie, Shimelis
    Wubet, Walelign
    HELIYON, 2021, 7 (07)
  • [30] Differential pulse voltammetric determination of ciprofibrate in pharmaceutical formulations using a glassy carbon electrode modified with functionalized carbon nanotubes within a poly(allylamine hydrochloride) film
    Takeda, Humberto H.
    Janegitz, Bruno C.
    Medeiros, Roberta A.
    Mattoso, Luiz H. C.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 755 - 760