A thermoluminescent dosimetry postal dose inter-comparison of radiation therapy centres in Malaysia

被引:9
|
作者
Rassiah P. [1 ,4 ]
Ng K.H. [2 ]
DeWerd L.A. [3 ]
Kunugi K. [3 ]
机构
[1] Clinical Oncology Unit, University of Malaya Medical Centre, Kuala Lumpur
[2] Department of Radiology, University of Malaya Medical Centre, Kuala Lumpur
[3] University of Wisconsin-Madison, Department of Medical Physics, Madison, WI
[4] The University of Texas, Health Science Center at San Antonio, San Antonio, TX 78229-3900
关键词
Dose inter-comparison; Mailed dosimetry; Radiotherapy; TLD;
D O I
10.1007/BF03178885
中图分类号
学科分类号
摘要
A thermoluminescent dosimetry (TLD) postal dose inter-comparison was carried out amongst radiotherapy centres in Malaysia. The aim of this TLD inter-comparison was to compare the uniformity involved in the measurement of absorbed dose among the participating centres. A set of 5 TLD chips placed within acrylic trays were mailed to all participating centres for irradiation to an absorbed dose to water of 2 Gy. Measurements were made for 6 MV and 60Co photon beams. Results show an agreement of =5% for all but three radiotherapy centres. The ratios of the TLD readings to that of the reference centre are comparable with other national/regional dose inter-comparisons. The importance of a proper ongoing quality assurance program is essential in maintaining the consistency and uniformity of doses delivered. Copyright © ACPSEM/EA.
引用
收藏
页码:25 / 29
页数:4
相关论文
共 50 条
  • [31] A COMPARISON OF IN-AIR AND IN-WATER CALIBRATION OF A DOSIMETRY SYSTEM USED FOR RADIATION DOSE ASSESSMENT IN CANCER THERAPY
    Arshed, Waheed
    Mahmood, Khalid
    Qazi, Ikramullah
    Ullah, Asad
    Akhter, Perveen
    Ahmad, Syed Salman
    Jamil, Zeeshan
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2010, 25 (01): : 51 - 54
  • [32] Inter-comparison study between human and cow teeth enamel for low dose measurement using ESR
    Hassan, G. M.
    Aboelezz, E.
    El-Khodary, A.
    Eissa, H. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (14): : 2329 - 2336
  • [33] Characteristics of longwave radiation through the statistical analysis of downward and upward longwave radiation and inter-comparison of two sites in Cyprus
    Pashiardis, S.
    Kalogirou, S. A.
    Pelengaris, A.
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2017, 164 : 60 - 80
  • [34] Inter-comparison study of the population dose due to gamma-radiation in the coast of North Sinai between Rafah and Bir El-Abd areas
    Seddeek, M. K.
    Sharshar, T.
    Badran, H. M.
    RADIATION PROTECTION DOSIMETRY, 2009, 135 (04) : 261 - 267
  • [35] Inter-comparison of different models for estimating clear sky solar global radiation for the Negev region of Israel
    Ianetz, Amiran
    Lyubansky, Vera
    Setter, Ilan
    Kriheli, Boris
    Evseev, Efim G.
    Kudish, Avraham I.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (01) : 259 - 268
  • [36] Thermoluminescent dosimeters (TLDs-100) calibration for dose verification in photon and proton radiation therapy
    D'Avino, V.
    Caruso, M.
    Arrichiello, C.
    Ametrano, G.
    La Verde, G.
    Muto, P.
    Scifoni, E.
    Tommasino, F.
    Pugliese, M.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (06):
  • [37] Statistical analysis for the characterization of solar energy utilization and inter-comparison of solar radiation at two sites in Cyprus
    Pashiardis, S.
    Kalogirou, S. A.
    Pelengaris, A.
    APPLIED ENERGY, 2017, 190 : 1138 - 1158
  • [38] Dosimetry for quantitative analysis of the effects of low-dose ionizing radiation in radiation therapy patients
    Lehmann, J
    Stern, RL
    Daly, TP
    Rocke, DM
    Schwietert, CW
    Jones, GE
    Arnold, ML
    Siantar, CLH
    Goldberg, Z
    RADIATION RESEARCH, 2006, 165 (02) : 240 - 247
  • [39] Development of a dosimetry inter-comparison for IMRT as part of site credentialing for a TROG multi-centre clinical trial for prostate cancer
    Healy, B.
    Frantzis, J.
    Murry, R.
    Martin, J.
    Middleton, M.
    Catton, C.
    Kron, T.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 195 - 202
  • [40] Development of a dosimetry inter-comparison for IMRT as part of site credentialing for a TROG multi-centre clinical trial for prostate cancer
    B. Healy
    J. Frantzis
    R. Murry
    J. Martin
    M. Middleton
    C. Catton
    T. Kron
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34