Pixelated prompt gamma imaging detector for online measurement of proton beam: Monte Carlo feasibility study by FLUKA

被引:6
|
作者
Wang J.-L. [1 ,2 ]
Cruz L.A. [2 ]
Lu M. [3 ]
机构
[1] School of Astronomy and Space Science, Nanjing University, Nanjing
[2] NewRT Medical systems, Inc., Wuxi
[3] Peak Physics Consulting, LLC., Guangzhou
关键词
Beam range; FLUKA; Prompt gamma; Proton therapy;
D O I
10.1007/s41605-017-0032-0
中图分类号
学科分类号
摘要
Increased accuracy of proton beam delivery provides additional benefits to the patients undergo the treatment. A prompt gamma imaging detector can provide additional information during the treatment, as the prompt gammas produced by the interactions between protons and human tissues are related to the range and profile of the beam in the patient. This paper makes a Monte Carlo feasibility study for a pixelated prompt gamma imaging detector which can not only measure the proton range but also merge the beam profile and 3D beam image inside the patient. FLUKA simulation result shows that this detector can reduce background noise and measure the range and beam profile by using of grated shielding material, vertical gammas selection and a 5 MeV energy window. © 2018, Institute of High Energy Physics, Chinese Academy of Sciences; China Nuclear Electronics and Nuclear Detection Society and Springer Nature Singapore Pte Ltd.
引用
收藏
相关论文
共 50 条
  • [21] Quantum Entanglement Filtering: A PET Feasibility Study in Imaging Dual-Positron and Prompt Gamma Emission via Monte Carlo Simulation
    Romanchek, Gregory
    Shoop, Greyson
    Gholami, Kimia
    Enlow, Emily
    Abbaszadeh, Shiva
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (08) : 916 - 925
  • [22] Sensitivity study of prompt gamma imaging of scanned beam proton therapy in heterogeneous anatomies
    Janssens, Guillaume
    Smeets, Julien
    Stappen, Francois Vander
    Prieels, Damien
    Clementel, Enrico
    Hotoiu, Eugen-Lucian
    Sterpin, Edmond
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (03) : 562 - 567
  • [23] A Feasibility Study of Using a Cherenkov Detector Material with the Prompt Gamma Range Verification Technique in Proton Therapy
    Lau, A.
    Ahmad, S.
    Chen, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3567 - 3568
  • [24] Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector
    Verburg, J.
    Testa, M.
    Cascio, E.
    Bortfeld, T.
    Lu, H.
    Seco, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 495 - 495
  • [25] Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study
    Lee, Youngjin
    Park, Chanrok
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (12) : 4652 - 4659
  • [26] Proton breast treatments: eclipse vs Monte Carlo Fluka dose comparison study
    Fiorini, F.
    Hackett, S.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S790 - S790
  • [27] A Feasibility Study of a Monte Carlo Based Dose Verification for a Therapeutic Proton Beam Delivery System
    Shin, Jungwook
    Kwak, Jungwon
    Kim, Dong Wook
    Shin, Dongho
    Yoon, Myongguen
    Park, Soah
    Lim, Young Kyung
    Kim, Jin Sung
    Park, Sung Yong
    Cho, Kwan Ho
    Lee, Se Byeong
    MEDICAL PHYSICS, 2008, 35 (06)
  • [28] A deep learning approach for converting prompt gamma images to proton dose distributions: A Monte Carlo simulation study
    Liu, Chih-Chieh
    Huang, Hsuan-Ming
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 110 - 119
  • [29] A novel concept of adjustable three-layer collimator in a pixelated photon-counting detector for gamma-ray imaging: Monte Carlo simulation study
    Park, Chanrok
    Lee, Youngjin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1051
  • [30] Monte Carlo Design Study of a Gamma Detector System to Locate Distal Dose Falloff in Proton Therapy
    Kang, Byung-Hwi
    Kim, Jong-Won
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 46 - 50