Field investigation on the spatiotemporal thermal-deformation characteristics of a composite embankment with two-phase closed thermosyphons on a permafrost slope

被引:0
|
作者
Mingyi Zhang
Wei Yang
Yuanming Lai
Wansheng Pei
Yanqiao Zhou
Miaomiao Bai
机构
[1] Northwest Institute of Eco-Environment and Resources,State Key Laboratory of Frozen Soil Engineering
[2] Chinese Academy of Sciences,School of Architecture and Civil Engineering
[3] University of Chinese Academy of Sciences,undefined
[4] Xi’an University of Science and Technology,undefined
来源
Acta Geotechnica | 2023年 / 18卷
关键词
Composite embankment; Cooling characteristics; L-shaped two-phase closed thermosyphon (LTPCT); Permafrost slope; Thermal-deformation;
D O I
暂无
中图分类号
学科分类号
摘要
The degradation of permafrost caused by climate change and engineering disturbance significantly affects infrastructure stability and transportation safety. Two-phase closed thermosyphons (TPCTs) were widely used to tackle external disturbances by cooling the permafrost stratum in permafrost engineering. However, existing research mainly focuses on the thermal performance of TPCTs. To evaluate the spatiotemporal thermal-deformation characteristics of a composite embankment with L-shaped two-phase closed themosyphons (LTPCTs) on a permafrost slope, we built the first spatiotemporal thermal-deformation observation system for a permafrost embankment with LTPCTs and insulation along the Gonghe-Yushu Highway in the Qinghai-Tibet Plateau, as well as a contrast embankment only with insulation (as a control). The observation results during the first five-year service period indicate that: (1) The cooling performance of LTPCT is determined by the air temperature, and the exterior wall temperature at the top of the evaporator section is significantly affected by the surface ground; additionally, its maximum effective cooling scope is no more than 2.0 m; (2) The LTPCTs can effectively cool down the underlying permafrost in the middle of the composite embankment, and reduce the settlement of the centerline after the second service year; (3) The deformation in the middle of the composite embankment is mainly from the layer of −3.5 to −6.0 m under the bottom of the asphalt layer in the first three years; (4) The maximum settlement near the long sunny slope of the composite embankment can reach 4 times of that at the centerline, and the continuously increasing deformation difference along the cross section may cause longitudinal cracks of the embankment, and influence the traffic safety. Therefore, it is believed that the research results can promote acknowledge for the composite embankments with LTPCTs used in a permafrost slope.
引用
收藏
页码:5427 / 5439
页数:12
相关论文
共 50 条
  • [41] Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
    Zhou, Yalong
    Wang, Xu
    Guo, Chunxiang
    Hu, Yuan
    He, Fei
    Liu, Deren
    Jiang, Daijun
    MATERIALS, 2022, 15 (23)
  • [42] Thermo-seismic performances of a unilateral two-phase closed thermosyphon (TPCT) embankment in earthquake-prone permafrost regions
    Li, Shuangyang
    Pei, Wansheng
    Wang, Chong
    Lai, Yuanming
    Shi, Lianghong
    TRANSPORTATION GEOTECHNICS, 2021, 27
  • [43] Effect of evaporator curvature on the local non-equilibrium heat regulation in two-phase closed thermosyphon embankment in permafrost regions
    Pei, Wansheng
    Du, Shuai
    Zhang, Mingyi
    Zhou, Yanqiao
    Ji, Yanjun
    ENERGY, 2024, 301
  • [44] Numerical study of the thermal characteristics of a shallow tunnel section with a two-phase closed thermosyphon group in a permafrost region under climate warming
    Zhang, Mingyi
    Pei, Wansheng
    Lai, Yuanming
    Niu, Fujum
    Li, Shuangyang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 104 : 952 - 963
  • [45] Effects of a Nanofluid and Magnetic Field on the Thermal Efficiency of a Two-Phase Closed Thermosyphon
    Salehi, Hadi
    Heris, Saeed
    Sharifi, Fateme
    Razbani, Mohammad
    HEAT TRANSFER-ASIAN RESEARCH, 2013, 42 (07): : 630 - 650
  • [46] Experimental Study of Thermal Performance and Pressure Differences of Different Working Fluids in Two-phase Closed Thermosyphons Using Solar Energy
    Ozbas, Engin
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2019, 22 (01): : 121 - 128
  • [47] Theoretical investigation on thermal hydraulic characteristics of boiling two-phase sodium
    Qiu Z.
    Lan Z.
    Ma Z.
    Qiu S.
    Zan Y.
    Xing D.
    Li Y.
    Hedongli Gongcheng, (121-124): : 121 - 124
  • [48] AN EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF TWO-PHASE CLOSED THERMOSYPHON USING ZIRCONIA NANOFLUID
    Tharves Mohideen, Sheik I.
    Suresh Kumar, Ramasamy
    THERMAL SCIENCE, 2016, 20 (05): : 1565 - 1574
  • [49] A comparative investigation on the effect of different nanofluids on the thermal performance of two-phase closed thermosyphon
    Xu, Qian
    Liu, Lin
    Feng, Junxiao
    Qiao, Lihong
    Yu, Chuqiao
    Shi, Wenjun
    Ding, Chong
    Zang, Yong
    Chang, Chun
    Xiong, Yaxuan
    Ding, Yulong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 149