2D sense for faster 3D MRI

被引:0
|
作者
Markus Weiger
Klaas P. Pruessmann
Peter Boesiger
机构
[1] University of Zurich and Swiss Federal Institute of Technology Zurich,Institute for Biomedical Engineering
关键词
Sensitivity encoding; 2D SENSE; Fast 3D MRI;
D O I
10.1007/BF02668182
中图分类号
学科分类号
摘要
Sensitivity encoding in two spatial dimensions (2D SENSE) with a receiver coil array is discussed as a means of improving the encoding efficiency of three-dimensional (3D) Fourier MRI. it is shown that in Fourier imaging with two phase encoding directions, 2D SENSE has key advantages over one-dimensional parallel imaging approaches. By exploiting two dimensions for hybrid encoding, the conditioning of the reconstruction problem can be considerably improved, resulting in superior signal-to-noise behavior. As a consequence, 2D SENSE permits greater scan time reduction, which particularly benefits the inherently time-consuming 3D techniques.
引用
收藏
页码:10 / 19
页数:9
相关论文
共 50 条
  • [21] 2D & 3D Shepp-Logan phantom standards for MRI
    Gach, H. Michael
    Tanase, Costin
    Boada, Femando
    ICSENG 2008: INTERNATIONAL CONFERENCE ON SYSTEMS ENGINEERING, 2008, : 521 - +
  • [22] Dynamic breast MRI with spiral trajectories: 3D versus 2D
    Yen, YF
    Han, KF
    Daniel, BL
    Heiss, S
    Birdwell, RL
    Herfkens, RJ
    Sawyer-Glover, AM
    Glover, GH
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (04): : 351 - 359
  • [23] Effusive constrictive pericarditis: 2D, 3D echocardiography and MRI imaging
    Zagol, Brian
    Minderman, Daniel
    Munir, Ahmad
    D'Cruz, Ivan
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10): : 1110 - 1114
  • [24] 2D multislice and 3D MRI sequences are often equally sensitive
    Johnson, G
    Wadghiri, YZ
    Turnbull, DH
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (04) : 824 - 828
  • [25] Comparison of 2D and 3D MRI of the optic and oculomotor nerve anatomy
    Held, P
    Nitz, W
    Seitz, J
    Fründ, R
    Müller, HM
    Haffke, T
    Hees, H
    CLINICAL IMAGING, 2000, 24 (06) : 337 - 343
  • [26] 21/2D or 3D?
    Roth, S
    Küster, B
    Sura, H
    KUNSTSTOFFE-PLAST EUROPE, 2004, 94 (07): : 65 - 67
  • [27] 2D and 3D on demand
    Philippi, Anne
    F & M; Feinwerktechnik, Mikrotechnik, Messtechnik, 1998, 106 (06): : 412 - 414
  • [28] From 2D to 3D
    Steven De Feyter
    Nature Chemistry, 2011, 3 (1) : 14 - 15
  • [29] Faster 3D GPR Imaging Using 2D Dictionaries with Applications to Sparse Reconstruction
    Duman, Muhammed
    Gurbuz, Ali Cafer
    ICECCO'12: 9TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTER AND COMPUTATION, 2012, : 232 - 236
  • [30] 3D dobutamine stress echocardiography:: comparable results to 2D technique, but faster and easier?
    Breithardt, OA
    Rulands, D
    Kühl, HR
    Franke, A
    EUROPEAN HEART JOURNAL, 2004, 25 : 341 - 342