Erythrocyte fouling on micro-engineered membranes

被引:0
|
作者
Levy I. Amar
Daniela Guisado
Monica Faria
James P. Jones
Cees J. M. van Rijn
Michael I. Hill
Edward F. Leonard
机构
[1] Columbia University,Department of Biomedical Engineering
[2] Columbia University,Department of Chemical Engineering
[3] Mount Sinai St. Luke’s Roosevelt Hospital,Department of Nephrology
[4] Wageningen University Stippeneng,MicroFluidics and NanoTechnology/ORC
来源
Biomedical Microdevices | 2018年 / 20卷
关键词
Cross-flow; Microfluidics; Microfiltration model; Microsieve; Sieve; Photolithography; Nanopores; Erythrocytes; Blood; Fouling;
D O I
暂无
中图分类号
学科分类号
摘要
Crossflow microfiltration of plasma from blood through microsieves in a microchannel is potentially useful in many biomedical applications, including clinically as a wearable water removal device under development by the authors. We report experiments that correlate filtration rates, transmembrane pressures (TMP) and shear rates during filtration through a microscopically high channel bounded by a low intrinsic resistance photolithographically-produced porous semiconductor membrane. These experiments allowed observation of erythrocyte behavior at the filtering surface and showed how their unique deformability properties dominated filtration resistance. At low filtration rates (corresponding to low TMP), they rolled along the filter surface, but at higher filtration rates (corresponding to higher TMP), they anchored themselves to the filter membrane, forming a self-assembled, incomplete monolayer. The incompleteness of the layer was an essential feature of the monolayer’s ability to support sustainable filtration. Maximum steady-state filtration flux was a function of wall shear rate, as predicted by conventional crossflow filtration theory, but, contrary to theories based on convective diffusion, showed weak dependence of filtration on erythrocyte concentration. Post-filtration scanning electron micrographs revealed significant capture and deformation of erythrocytes in all filter pores in the range 0.25 to 2 μm diameter. We report filtration rates through these filters and describe a largely unrecognized mechanism that allows stable filtration in the presence of substantial cell layers.
引用
收藏
相关论文
共 50 条
  • [41] Recent advancements in Micro-engineered devices for surface and deep brain animal studies: A review
    Bhaskara, Sreenivas
    Sakorikar, Tushar
    Chatterjee, Suman
    Girishan, K. V. Shabari
    Pandya, Hardik J.
    SENSING AND BIO-SENSING RESEARCH, 2022, 36
  • [42] Formation of size-tuneable biodegradable polymeric nanoparticles by solvent displacement method using micro-engineered membranes fabricated by laser drilling and electroforming
    Othman, Rahimah
    Vladisavljevic, Goran T.
    Shahmohamadi, Hamed
    Nagy, Zoltan K.
    Holdich, R. G.
    CHEMICAL ENGINEERING JOURNAL, 2016, 304 : 703 - 713
  • [43] Drop Detachment from a Micro-Engineered Membrane Surface in a Dynamic Membrane Emulsification Process
    Holzapfel, Sebastian
    Rondeau, Elisabeth
    Muehlich, Pascal
    Windhab, Erich J.
    CHEMICAL ENGINEERING & TECHNOLOGY, 2013, 36 (10) : 1785 - 1794
  • [44] Thermo-mechanical analysis of a micro-engineered tungsten-foam armored IFE FW
    Andersen, M
    Sharafat, S
    Ghoniem, N
    FUSION ENGINEERING AND DESIGN, 2006, 81 (8-14) : 1639 - 1645
  • [45] Angiogenic responses in a 3D micro-engineered environment of primary endothelial cells and pericytes
    Jing Bai
    Mehrdad Khajavi
    Lufei Sui
    Haojie Fu
    Subrahmanian Tarakkad Krishnaji
    Amy E. Birsner
    Lauren Bazinet
    Roger D. Kamm
    Robert J. D’Amato
    Angiogenesis, 2021, 24 : 111 - 127
  • [46] High throughput vegetable oil-in-water emulsification with a high porosity micro-engineered membrane
    Wagdare, Nagesh A.
    Marcelis, Antonius T. M.
    Ho, O. Boen
    Boom, Remko M.
    van Rijn, Cees J. M.
    JOURNAL OF MEMBRANE SCIENCE, 2010, 347 (1-2) : 1 - 7
  • [47] Angiogenic responses in a 3D micro-engineered environment of primary endothelial cells and pericytes
    Bai, Jing
    Khajavi, Mehrdad
    Sui, Lufei
    Fu, Haojie
    Tarakkad Krishnaji, Subrahmanian
    Birsner, Amy E.
    Bazinet, Lauren
    Kamm, Roger D.
    D'Amato, Robert J.
    ANGIOGENESIS, 2021, 24 (01) : 111 - 127
  • [48] Electrophoretic Deposition of Thermites onto Micro-Engineered Electrodes Prepared by Direct-Ink Writing
    Sullivan, K. T.
    Zhu, C.
    Tanaka, D. J.
    Kuntz, J. D.
    Duoss, E. B.
    Gash, A. E.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2013, 117 (06): : 1686 - 1693
  • [49] Organic Fouling of Graphene Oxide Membranes and Its Implications for Membrane Fouling Control in Engineered Osmosis
    Hu, Meng
    Zheng, Sunxiang
    Mi, Baoxia
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (02) : 685 - 693
  • [50] Application of Micro-Engineered Kidney, Liver, and Respiratory System Models to Accelerate Preclinical Drug Testing and Development
    Gholizadeh, Hanieh
    Cheng, Shaokoon
    Kourmatzis, Agisilaos
    Xing, Hanwen
    Traini, Daniela
    Young, Paul M.
    Ong, Hui Xin
    BIOENGINEERING-BASEL, 2022, 9 (04):