3D automated breast ultrasound imaging: equipment and image reconstruction

被引:5
|
作者
Luccas V.A.S. [1 ]
Azimbagirad M. [2 ]
Cabrelli L.C. [1 ]
Grillo F.W. [1 ]
Pavan T.Z. [1 ]
Otavio Murta L., Jr. [3 ]
Elias J., Jr. [4 ]
Carneiro A.A.O. [1 ]
机构
[1] Department of Physics, FFCLRP, University of São Paulo, Ribeirao Preto, SP
[2] Department of Medical Science and Health, University of Western Brittany, Brest
[3] Department of Computing and Mathematics, FFCLRP, University of São Paulo, Ribeirao Preto, SP
[4] Department of Medical Images, Hematology and Clinical Oncology, FMRP, University of São Paulo, Ribeirao Preto, SP
基金
巴西圣保罗研究基金会;
关键词
3D ultrasound imaging; Arduino; Breast tomography; Reconstruction techniques; Volumetric tumor analysis;
D O I
10.1007/s42600-021-00159-y
中图分类号
学科分类号
摘要
Purpose: It has been proven that early breast cancer diagnosis increases the success rate of treatment. Thus, annual mammography exam is recommended for women over forty which is relatively expensive, painful, and the safety of the used radiation dose is still debated. In this work, we introduced an automatic, low cost, and less painful exam to pre-diagnose the tumors of the breast. Method: The proposed imaging acquisition system uses a diagnostic ultrasound machine in B-mode, a linear probe, and a dedicated arm fixed below a bed in which all are controlled by a microcontroller. The breast is scanned underwater while patient is laid down on a bed in which the robotic arm guides the probe rotating to acquire a stack of 2D images. Then, we reconstructed the 3D image due to render the mammary volume, search for tumors, estimating the position, and volume size of them. We tuned and evaluated the imaging system using a control phantom made of paraffin-gel wax and deionized water, and a realistic breast phantom (Gphantom model), including eleven inclusions mimicking breast tumors. In addition, we scanned the phantoms by MRI and CT to evaluate the proposed method. Also, we scanned the breast of three invited volunteers and compared the results to their prior medical reports. Results: The precision in volume estimation of the tumor in the control phantom was 96.89%. Conclusion: The proposed hardware setup and image reconstruction was capable of identifying simulated tumors in the breast phantom and real tumor in vivo studies. © 2021, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:519 / 533
页数:14
相关论文
共 50 条
  • [21] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471
  • [22] Multi-modality 3D breast imaging with X-Ray tomosynthesis and automated ultrasound
    Sinha, Sumedha P.
    Roubidoux, Marilyn A.
    Helvie, Mark A.
    Nees, Alexis V.
    Goodsitt, Mitchell M.
    LeCarpentier, Gerald L.
    Fowlkes, J. Brian
    Chalek, Carl L.
    Carson, Paul L.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1335 - +
  • [23] A Clinical Experience of a Prototype Automated Breast Ultrasound System Combining Transmission and Reflection 3D Imaging
    Pellegretti, P.
    Vicari, M.
    Zani, M.
    Weigel, M.
    Borup, D.
    Wiskin, J.
    Saueressig, U.
    Kotter, E.
    Langer, M.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1407 - 1410
  • [24] 3D Ultrasound Imaging in Image-Guided Intervention
    Fenster, Aaron
    Bax, Jeff
    Neshat, Hamid
    Cool, Derek
    Kakani, Nirmal
    Romagnoli, Cesare
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6151 - 6154
  • [25] Automated linking of suspicious findings between automated 3D breast ultrasound volumes
    Gubern-Merida, Albert
    Tan, Tao
    van Zelsta, Jan
    Mann, Ritse M.
    Karssemeijer, Nico
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [26] Automated 3D ultrasound elastography of the breast: a phantom validation study
    Hendriks, Gijs A. G. M.
    Hollander, Branislav
    Menssen, Jan
    Milkowski, Andy
    Hansen, Hendrik H. G.
    de Korte, Chris L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07): : 2665 - 2679
  • [27] Lesion Segmentation in Automated 3D Breast Ultrasound: Volumetric Analysis
    Agarwal, Richa
    Diaz, Oliver
    Llado, Xavier
    Gubern-Merida, Albert
    Vilanova, Joan C.
    Marti, Robert
    ULTRASONIC IMAGING, 2018, 40 (02) : 97 - 112
  • [28] Chest wall segmentation in automated 3D breast ultrasound scans
    Tan, Tao
    Platel, Bram
    Mann, Ritse M.
    Huisman, Henkjan
    Karssemeijer, Nico
    MEDICAL IMAGE ANALYSIS, 2013, 17 (08) : 1273 - 1281
  • [29] 3D breast microwave imaging based on wavefront reconstruction
    Flores-Tapia, Daniel
    Thomas, Gabriel
    Ashtari, Ali
    Pistorius, Stephen
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4693 - +
  • [30] A Probe-Camera System for 3D Ultrasound Image Reconstruction
    Ito, Koichi
    Yodokawa, Kouya
    Aoki, Takafumi
    Ohmiya, Jun
    Kondo, Satoshi
    IMAGING FOR PATIENT-CUSTOMIZED SIMULATIONS AND SYSTEMS FOR POINT-OF-CARE ULTRASOUND, 2017, 10549 : 129 - 137