Electric-arc erosion of metal plates of arc suppressors of automatic circuit breakers for extreme commutation currents

被引:9
|
作者
Markevich N.V. [1 ]
Kiyatkin R.P. [1 ]
Maksimov O.P. [2 ]
机构
[1] St. Petersburg State Polytechnic University,
[2] OAO Novaya Era,undefined
来源
Russ Electr Eng | 2007年 / 12卷 / 670-673期
关键词
5;
D O I
10.3103/S1068371207120073
中图分类号
学科分类号
摘要
Electric-arc erosion of deion plates of arc suppressors of automatic circuit breakers during at switch-off of extreme commutation currents is investigated. The proposed technique is used to evaluate the effect of electrodynamic forces of the electric switch-off arc in the limiting short-circuit regimes. © 2007 Allerton Press, Inc.
引用
收藏
页码:670 / 673
页数:3
相关论文
共 50 条
  • [21] CALCULATION OF CHEMICAL COMPOSITION OF METAL DEPOSITED BY ELECTRIC-ARC METHOD
    PAVLYUK, SK
    KUZMENKO, IM
    WELDING PRODUCTION, 1975, 22 (12): : 14 - 17
  • [22] EROSION OF ELECTRICAL CONTACTS UNDER THE EFFECT OF A HIGH-INTENSITY ELECTRIC-ARC
    ANDANSON, P
    LEFORT, A
    ROCHE, J
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1979, 12 (03) : 395 - 400
  • [23] Simulation by Neural Networks of Electric Arc Quenching in High Voltage Circuit Breakers
    Bryantsevich, Alexandro
    REVISTA DIGITAL LAMPSAKOS, 2010, (04): : 7 - 11
  • [24] Approach Analysis of Modeling of Electric Arc for Use in Circuit Breakers' Special Conditions
    Vajnar, Vladimir
    Sedlacek, Jan
    Vostracky, Zdenek
    ENERGY ECOLOGY ECONOMY 2018, 2018, : 186 - 191
  • [25] Cleaning asipiration air from chambers for electric-arc metal spraying
    Aleksandrov, VP
    Glupanov, VN
    CHEMICAL AND PETROLEUM ENGINEERING, 2002, 38 (1-2) : 94 - 95
  • [26] Cleaning Asipiration Air from Chambers for Electric-Arc Metal Spraying
    V. P. Aleksandrov
    V. N. Glupanov
    Chemical and Petroleum Engineering, 2002, 38 : 94 - 95
  • [27] THE THERMAL EFFECT OF A MOVING ELECTRIC-ARC ON COATED METAL-ELECTRODES
    BORISOV, RK
    LARIONOV, VP
    PROKHOROV, YN
    REUTSKII, AV
    ELECTRICAL TECHNOLOGY, 1988, (02): : 75 - 82
  • [28] 110-KV ELECTRIC-ARC MELTING FURNACE WITH POWER CIRCUIT-BREAKER IN INTERMEDIATE CIRCUIT
    KAEMPF, P
    MARKWORT.E
    MUHLENBE.J
    STAHL UND EISEN, 1974, 94 (09): : 393 - 393
  • [29] SIMULATION OF ELECTRIC ARCS IN CIRCUIT-BREAKERS BY MEANS OF A DYNAMIC ARC MODEL.
    Sakulin, M.
    Hirtler, R.
    Modelling, Measurement and Control A, 1984, 1 (03): : 41 - 64
  • [30] An Analysis of the Performance of Power Circuit Breakers Using the Modelling of Electric Arc and a Radiometric System
    Kuhlmann, Gustavo
    Mustafa, Thair I. A. H.
    Pitz, Ciro A.
    Almaguer, Hugo D.
    Meyer, Luiz H.
    Cabral, Sergio H. L.
    Flores, Fernando T.
    Cereja, Jose Eduardo
    Puchale, Leandro T.
    2017 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2017,