Radiation dose exposure of patients undergoing 320-row cardiac CT for assessing coronary angiography and global left ventricular function

被引:1
|
作者
Chien-Ming Chen
Yuan-Chang Liu
Chun-Chi Chen
Ming-Shien Wen
Chien-Fu Hung
Yung-Liang Wan
机构
[1] Chang Gung University,Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, College of Medicine
[2] Chang Gung University,2nd Section of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital at Linkou, College of Medicine
关键词
Coronary CT angiography; Multidetector CT; Prospective ECG-gating; Radiation dose;
D O I
暂无
中图分类号
学科分类号
摘要
A 320-row multidetector CT provides the capability for prospective electrocardiogram (ECG)-gated coronary CT angiography (CTA) and tube current modulated cardiac function assessment (CFA). We assessed and compared the effective radiation dose of these two modes. On a prospective basis, we performed ECG-gated cardiac CT on 119 patients (87 were males). For heart rates (HRs) ≦65 beats/min (bpm), we used one-heartbeat acquisition and half-scan reconstruction. HRs from 66 to 79 bpm and ≧80 bpm were scanned with either two or three heartbeats acquisitions, respectively. We used two types of scans. One type was based on a prospective ECG-gated CTA mode and the other using a tube current modulated CFA mode covering an entire R–R interval. The mean BMI of patients was 25.4 (range 18.8–49.3). Fifty-one patients (42.9 %) underwent CFA scanning, while the remaining 68 (57.1 %) had CTA. The majority of patients completed the scan in a single heartbeat (59.7 %). The mean dose of CTA mode at 65–85 % phase window for one and two heartbeats was 3.68 mSv (2.40–7.23) and 8.61 mSv (6.76–10.60), respectively. The mean dose of CFA mode for a single heartbeat measurement with dose modulation (25 % dose for CFA, and 100 % dose during 65–85 % phase window for CTA) was 6.32 mSv (4.69–8.89). CTA with prospective ECG-gating allows for acceptable image quality and radiation dose. HR reduction is mandatory to minimize radiation exposure. Global left ventricle function can be assessed with a single heartbeat within an acceptable radiation dose.
引用
收藏
页码:1 / 5
页数:4
相关论文
共 50 条
  • [31] DIAGNOSTIC ACCURACY OF 64-ROW AND 320-ROW MULTIDETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY IN DIALYSIS PATIENTS
    Shinohara, Masaya
    Jiro, Aoki
    Tatsuyuki, Sato
    Kentaro, Yasuhara
    Nahoko, Kato
    Koichi, Furui
    Yu, Horiuchi
    Mika, Watanabe
    Masahiko, Asami
    Tanimoto, Shuzou
    Kazuhiro, Hara
    Tanabe, Kengo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1132 - A1132
  • [32] Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT
    Vilades Medel, David
    Leta, Ruben
    Alomar Serralach, Xavier
    Carreras Costa, Francesc
    Pons-Llado, Guillem
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3208 - 3214
  • [33] Assessment of global left ventricular function and volumes with 320-row multidetector computed tomography: A comparison with 2D-echocardiography
    de Graaf, Fleur R.
    Schuijf, Joanne D.
    van Velzen, Joella E.
    Nucifora, Gaetano
    Kroft, Lucia J.
    de Roos, Albert
    Schalij, Martin J.
    Jukema, J. Wouter
    van der Wall, Ernst E.
    Bax, Jeroen J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (02) : 225 - 231
  • [34] Comparison of position, morphology and calcification of Coronary Plaque with 320-row dynamic volume CT (DVCT) and coronary angiography (CAG)
    Li, Xiaoyan
    Zhang, Guoming
    Zhang, Hongming
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (04) : 824 - 829
  • [35] Assessment of global left ventricular function and volumes with 320-row multidetector computed tomography: A comparison with 2D-echocardiography
    Fleur R. de Graaf
    Joanne D. Schuijf
    Joëlla E. van Velzen
    Gaetano Nucifora
    Lucia J. Kroft
    Albert de Roos
    Martin J. Schalij
    J. Wouter Jukema
    Ernst E. van der Wall
    Jeroen J. Bax
    Journal of Nuclear Cardiology, 2010, 17 : 225 - 231
  • [36] Radiation exposure and determinants of radiation dose for coronary CT angiography. analysis of 2275 patients in the German cardiac CT registry
    Hausleiter, J.
    Hadamitzky, M.
    Limbourg, T.
    Schmermund, A.
    Bruder, O.
    Leber, A.
    Schroeder, S.
    Rixe, J.
    Senges, J.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 524 - 524
  • [37] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Pan, Yue-ying
    Zhou, Shu-chang
    Wang, Yu-jin
    Li, Qian
    Zhu, Ting-ting
    Liu, Chun-xia
    Guan, Han-xiong
    CURRENT MEDICAL SCIENCE, 2020, 40 (01) : 178 - 183
  • [38] Low dose 320-row CT for left atrium and pulmonary veins imaging-the feasibility study
    Yang, Lin
    Xu, Lei
    Yan, Zixu
    Yu, Wei
    Fan, Zhanming
    Lv, Biao
    Zhang, Zhaoqi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1549 - 1554
  • [39] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Yue-ying Pan
    Shu-chang Zhou
    Yu-jin Wang
    Qian Li
    Ting-ting Zhu
    Chun-xia Liu
    Han-xiong Guan
    Current Medical Science, 2020, 40 : 178 - 183
  • [40] Coronary computed tomography angiography and endocardial leads - Image quality in 320-row CT using iterative reconstruction
    Garmer, Marietta
    Bonsels, Marc
    Metz, Frauke
    Klein-Wiele, Oliver
    Brandts, Bodo
    Groenemeyer, Dietrich
    CLINICAL IMAGING, 2018, 50 : 157 - 163