A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT

被引:0
|
作者
E. Gordon DePuey
Srinivas Bommireddipalli
John Clark
Anna Leykekhman
Linda B. Thompson
Marvin Friedman
机构
[1] St. Luke’s-Roosevelt Hospital and Columbia University College of Physicians and Surgeons,Division of Nuclear Medicine, Department of Radiology
来源
关键词
Gated SPECT; image processing; instrumentation: SPECT; iterative reconstruction; radiation dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:273 / 280
页数:7
相关论文
共 50 条
  • [21] Wide-beam reconstruction half-time SPECT improves diagnostic certainty and preserves normalcy and accuracy: A quantitative perfusion analysis
    Regina S. Druz
    Lawrence M. Phillips
    Michelle Chugkowski
    Loukas Boutis
    Bruce Rutkin
    Stanley Katz
    Journal of Nuclear Cardiology, 2011, 18 : 52 - 61
  • [22] Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximum
    E. Gordon DePuey
    Srinivas Bommireddipalli
    John Clark
    Linda Thompson
    Yossi Srour
    Journal of Nuclear Cardiology, 2009, 16 : 736 - 752
  • [23] Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum
    DePuey, E. Gordon
    Bommireddipalli, Srinivas
    Clark, John
    Thompson, Linda
    Srour, Yossi
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) : 736 - 752
  • [24] Patient Acceptance of Half-dose Vs. Half-time Molecular Breast Imaging
    Swanson, Tiffinee N.
    Tran, Thuy D.
    Hruska, Carrie B.
    Solberg, Courtney M.
    Rhodes, Deborah J.
    Hunt, Katie N.
    Conners, Amy Lynn
    O'Connor, Michael K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2018, 49 (01) : 39 - 43
  • [25] XPRESS3-Half-Dose/Half-Time GATED Cardiac SPECT Validation
    Pena, H.
    Cantinho, G.
    Pereira, L.
    Magno, I.
    Graca, A.
    Wilk, M.
    Srour, Y.
    Godinho, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S201 - S202
  • [26] Gated Myocardial Perfusion SPECT with Quarter-time Wide Beam Reconstruction
    Depuey, G.
    Bommireddipalli, S.
    Clark, J.
    Thompson, L.
    Leykekhman, A.
    Friedman, M.
    Kemany, H.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S47 - S48
  • [27] Quarter-time myocardial perfusion SPECT using wide beam reconstruction
    DePuey, E. Gordon
    Bommireddipalli, Srinivas
    Friedman, Marvin
    Beletsky, Ilya
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A172 - A172
  • [28] Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients
    M. Lecchi
    I. Martinelli
    O. Zoccarato
    C. Maioli
    Giovanni Lucignani
    A. Del Sole
    Journal of Nuclear Cardiology, 2017, 24 : 876 - 887
  • [29] Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients
    Lecchi, M.
    Martinelli, I.
    Zoccarato, O.
    Maioli, C.
    Lucignani, Giovanni
    Del Sole, A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 876 - 887
  • [30] Half-time myocardial perfusion SPECT imaging with attenuation and Monte Carlo-based scatter correction
    Kangasmaa, Tuija S.
    Kuikka, Jyrki T.
    Vanninen, Esko J.
    Mussalo, Hanna M.
    Laitinen, Tomi P.
    Sohlberg, Antti O.
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (11) : 1040 - 1045