A Weak Signal Extraction Method for Human Blood Glucose Noninvasive Measurement using Near Infrared Spectroscopy

被引:0
|
作者
Li-Na Li
Qing-Bo Li
Guang-Jun Zhang
机构
[1] Key Laboratory of Education Ministry,School of Instrumentation Science and Opto
关键词
Uninformative variable elimination; Successive projections algorithm; Blood glucose noninvasive measurement; Near infrared spectroscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Background interference from optical absorption of matrix components, low spectral selectivity and low spectral sensitivity are the main interference factors for human blood glucose noninvasive measurement using near infrared (NIR) spectroscopy. In order to extract the weak glucose concentration information, a modified uninformative variable elimination (mUVE) method combined with successive projections algorithm (SPA) named as mUVE-SPA, is proposed. mUVE is used to eliminate matrix background and high-frequency noise by wavelet multi-resolution technology. SPA is followed to select variables with minimum colinearity by projection algorithm in a vector space. The proposed method was applied in two NIR spectra data sets (plasma samples experiment in vitro and human blood glucose noninvasive measurement experiment in vivo) respectively. The performance and adaptability of the proposed strategy were discussed. The results indicate that the proposed hybrid method can give an alternative path to extract weak glucose information and yield more parsimonious models with higher precision.
引用
收藏
页码:1191 / 1204
页数:13
相关论文
共 50 条
  • [21] Application of Partial Robust M-Regression in Noninvasive Measurement of Human Blood Glucose Concentration with Near-Infrared Spectroscopy
    Li Qing-bo
    Yan Hou-lai
    Li Li-na
    Wu Jin-guang
    Zhang Guang-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (08) : 2115 - 2119
  • [22] Noninvasive Blood Glucose Detection Using Near Infrared Sensor
    Hotmartua, Rolamjaya
    Pangestu, Pujianto Wira
    Zakaria, Hasballah
    Irawan, Yoke Saadia
    5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, 2015, : 687 - 692
  • [23] Noninvasive Measurement of Glucose in Artificial Plasma with Near-Infrared and Raman Spectroscopy
    Xue, Jintao
    Chen, Han
    Xiong, Dongmei
    Huang, Guo
    Ai, Hong
    Liang, Yan
    Yan, Xinyu
    Gan, Yuan
    Chen, Cong
    Chao, Ruobing
    Ye, Liming
    APPLIED SPECTROSCOPY, 2014, 68 (04) : 428 - 433
  • [24] NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY
    HEISE, HM
    MARBACH, R
    KOSCHINSKY, T
    GRIES, FA
    ARTIFICIAL ORGANS, 1994, 18 (06) : 439 - 447
  • [25] Noninvasive Blood Glucose Measurements by Means of Near Infrared Spectroscopy: State of the Art
    Paez Roa, Arbey Alexis
    Villamizar Mejia, Rodolfo
    UIS INGENIERIAS, 2012, 11 (01): : 21 - 33
  • [26] Extraction of Effective Signal in Non-Invasive Blood Glucose Sensing with Near-Infrared Spectroscopy
    Han Guang
    Liu Rong
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (05) : 1599 - 1604
  • [27] Noninvasive Blood Glucose Analysis Based on Near-Infrared Reflectance Spectroscopy
    Lu Xiao-feng
    Zhang Ting-lin
    Xiao Feng
    Li Guang
    Wang You
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (07) : 2312 - 2317
  • [28] Quantitative Assessment of the Effect of Cholesterol on Blood Glucose Measurement Using Near Infrared Spectroscopy and a Method for Error Reduction
    Jiang, Jingying
    Zhang, Kai
    Qin, Jia
    Min, Xiaolin
    Zhang, Lingling
    Zou, Da
    Xu, Kexin
    LASERS IN SURGERY AND MEDICINE, 2015, 47 (01) : 88 - 97
  • [29] APPLICATION OF DENOISING AND BACKGROUND ELIMINATION BASED ON WAVELET TRANSFORM TO BLOOD GLUCOSE NONINVASIVE MEASUREMENT OF NEAR INFRARED SPECTROSCOPY
    Zhang Guang-Jun
    Li Li-Na
    Li Qing-Bo
    Xu Yu-Po
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2009, 28 (02) : 107 - 110
  • [30] Classification of diabetes and measurement of blood glucose concentration noninvasively using near infrared spectroscopy
    Li, Zhe
    Li, Gang
    Yan, Wen-Juan
    Lin, Ling
    INFRARED PHYSICS & TECHNOLOGY, 2014, 67 : 574 - 582