A Weak Signal Extraction Method for Human Blood Glucose Noninvasive Measurement using Near Infrared Spectroscopy

被引:0
|
作者
Li-Na Li
Qing-Bo Li
Guang-Jun Zhang
机构
[1] Key Laboratory of Education Ministry,School of Instrumentation Science and Opto
关键词
Uninformative variable elimination; Successive projections algorithm; Blood glucose noninvasive measurement; Near infrared spectroscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Background interference from optical absorption of matrix components, low spectral selectivity and low spectral sensitivity are the main interference factors for human blood glucose noninvasive measurement using near infrared (NIR) spectroscopy. In order to extract the weak glucose concentration information, a modified uninformative variable elimination (mUVE) method combined with successive projections algorithm (SPA) named as mUVE-SPA, is proposed. mUVE is used to eliminate matrix background and high-frequency noise by wavelet multi-resolution technology. SPA is followed to select variables with minimum colinearity by projection algorithm in a vector space. The proposed method was applied in two NIR spectra data sets (plasma samples experiment in vitro and human blood glucose noninvasive measurement experiment in vivo) respectively. The performance and adaptability of the proposed strategy were discussed. The results indicate that the proposed hybrid method can give an alternative path to extract weak glucose information and yield more parsimonious models with higher precision.
引用
收藏
页码:1191 / 1204
页数:13
相关论文
共 50 条
  • [1] A Weak Signal Extraction Method for Human Blood Glucose Noninvasive Measurement using Near Infrared Spectroscopy
    Li, Li-Na
    Li, Qing-Bo
    Zhang, Guang-Jun
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2009, 30 (11) : 1191 - 1204
  • [2] Research on the Effective Signal Extraction in the Noninvasive Blood Glucose Sensing by Near Infrared Spectroscopy
    Ding Hai-quan
    Lu Qi-peng
    Wang Dong-min
    Chen Xing-dan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (01) : 50 - 53
  • [3] A nonlinear model for calibration of blood glucose noninvasive measurement using near infrared spectroscopy
    Li, Qing-Bo
    Li, Li-Na
    Zhang, Guang-Jun
    INFRARED PHYSICS & TECHNOLOGY, 2010, 53 (05) : 410 - 417
  • [4] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Shiping
    Huang, Furong
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2007, 1 (06): : 307 - 311
  • [5] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Ship-Ing
    Huang, Fu-Rong
    Chen, Zhe
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (03): : 592 - 596
  • [6] New advancement in noninvasive measurement of blood glucose by near-infrared spectroscopy
    Li, QB
    Wang, Y
    Xu, KX
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 457 - 464
  • [7] Noninvasive and fast measurement of blood glucose in vivo by near infrared (NIR) spectroscopy
    Xue Jintao
    Ye Liming
    Liu Yufei
    Li Chunyan
    Chen Han
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 179 : 250 - 254
  • [8] Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
    K. V. Pozhar
    M. O. Mikhailov
    E. L. Litinskaia
    E. A. Polyakova
    Biomedical Engineering, 2022, 56 : 64 - 68
  • [9] Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
    Pozhar, K., V
    Mikhailov, M. O.
    Litinskaia, E. L.
    Polyakova, E. A.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2022, 56 (01): : 64 - 68
  • [10] Noninvasive measurement of postocclusive parameters in human forearm blood by near infrared spectroscopy
    Rao, KP
    Radhakrishnan, S
    Reddy, MR
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 443 - 447