Design of the Cryogen-Free Cryogenic System for the CUORE Experiment

被引:0
|
作者
A. Nucciotti
D. Schaeffer
F. Alessandria
R. Ardito
M. Barucci
L. Risegari
G. Ventura
C. Bucci
G. Frossati
M. Olcese
A. de Waard
机构
[1] Univ. di Milano-Bicocca and INFN Sez. di Milano-Bicocca,Dip. di Fisica “G. Occhialini”
[2] INFN Sez. di Milano dell’INFN,Dip. di Ingegneria Strutturale
[3] Politecnico di Milano,Dip. di Fisica
[4] Univ. di Firenze and INFN Sez. di Firenze,Dip. di Fisica
[5] INFN Laboratori Nazionali del Gran Sasso,Kamerlingh Onnes Laboratory
[6] Leiden Cryogenics,undefined
[7] Univ. di Roma La Sapienza and INFN Sez. di Roma 1,undefined
[8] Leiden University,undefined
来源
关键词
Dilution refrigerator; Pulse tube; Cryostat; Double beta decay; 07.20.Mc; 07.57.Kp; 07.10.Fq; 11.30.F;
D O I
暂无
中图分类号
学科分类号
摘要
We present here the final design of the cryogenic system where the CUORE detector will be installed in 2010. It is a large cryogen-free cryostat cooled by pulse tubes and by a high-power dilution refrigerator. To avoid radioactive background, about 15000 kg of lead will be cooled to below 1 K and only few construction materials are acceptable. The detector assembly will have a total mass of about 1500 kg and must be cooled to less than 10 mK in a vibration-free environment. We discuss the adopted technical solutions, the results of the preliminary thermal analysis of the system, and its expected performance.
引用
收藏
页码:662 / 668
页数:6
相关论文
共 50 条
  • [31] New cryogen-free design for superconducting mini-gap undulators
    Hobl, A
    Kubsky, S
    Dölling, D
    Geisler, A
    Komorowski, P
    Krischel, D
    Klein, U
    Rossmanith, R
    Moser, HO
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 1232 - 1235
  • [32] Design of a Cooling System for a REBCO Insert Coil in a Cryogen-Free 25 T Superconducting Magnet
    Iwai, S.
    Takahashi, M.
    Miyazaki, H.
    Tosaka, T.
    Tasaki, K.
    Hanai, S.
    Ioka, S.
    Watanabe, K.
    Awaji, S.
    Oguro, H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [33] The design of a compact cryogen-free superconducting wavelength shifter for synchrotron radiation
    Hwang, CS
    Chang, PC
    Chang, CH
    Hsiao, FZ
    Chen, CT
    Wang, B
    Juang, T
    Chen, JY
    Wahrer, R
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 503 - 506
  • [34] Design and construction performance of a compact cryogen-free superconducting wavelength shifter
    Hwang, CS
    Wang, B
    Wahrer, R
    Chen, HH
    Chang, CH
    Lin, FY
    Fan, TC
    Chen, CT
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 686 - 690
  • [35] Risk reduction benefits of cryogen-free refrigeration
    Cournoyer, Michael E.
    Pecos, James M.
    Chunglo, Steve D.
    Bonner, Charles
    Foster, Lynn A.
    Maez, Rudy J.
    Punjak, Wayne A.
    Wilburn, Dianne W.
    JOURNAL OF CHEMICAL HEALTH & SAFETY, 2012, 19 (03): : 29 - 33
  • [36] Cryogen-free one hundred microkelvin refrigerator
    Yan, Jiaojie
    Yao, Jianing
    Shvarts, Vladimir
    Du, Rui-Rui
    Lin, Xi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (02):
  • [37] Scanning SQUID microscopy in a cryogen-free cooler
    Shperber, Yishai
    Vardi, Naor
    Persky, Eylon
    Wissberg, Shai
    Huber, Martin E.
    Kalisky, Beena
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (05):
  • [38] Advances in the first cryogen-free hybrid magnet
    Watanabe, K
    Nishijima, G
    Awaji, S
    Takahashi, K
    Koyama, K
    Motokawa, M
    Ishizuka, A
    Hasebe, T
    Sakuraba, J
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 388 - 392
  • [39] Structural analysis of a cryogen-free refrigerator for space
    Emes, MR
    Hepburn, ID
    Ray, RJ
    Worth, LBC
    CRYOGENICS, 2001, 41 (11-12) : 771 - 779
  • [40] A cryogen-free dilution refrigerator based Josephson qubit measurement system
    Tian, Ye
    Yu, H. F.
    Deng, H.
    Xue, G. M.
    Liu, D. T.
    Ren, Y. F.
    Chen, G. H.
    Zheng, D. N.
    Jing, X. N.
    Lu, Li
    Zhao, S. P.
    Han, Siyuan