Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge

被引:0
|
作者
Timo Frett
Guido Petrat
Michael Arz
Carole Leguy
机构
[1] German Aerospace Center (DLR),Institute of Measuring and Sensor Technology
[2] Institute of Aerospace Medicine,undefined
[3] Ruhr West University of Applied Science,undefined
来源
Microgravity Science and Technology | 2021年 / 33卷
关键词
Telerobotic; Artificial gravity; Ultrasound imaging; Vascular response; Space physiology;
D O I
暂无
中图分类号
学科分类号
摘要
Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an ultrasound probe has been installed on a Short Arm Human Centrifuge. A feasibility study was conducted to define the use capabilities and limitations of such a novel method. The objective of this study is to estimate the reproducibility and precision of remotely controlled vascular ultrasound assessment under centrifugation by assessing peripheral vascular diameter and wall distension. Four repeated centrifugation runs of 5 min, with 2.4 g at feet level, were performed including a 15 min rest between each run for a group of eight healthy male volunteers. Vascular diameter and distention were assessed for the common carotid artery (CCA) and the femoral artery (FA) by ultrasound imaging using a 10 MHz linear array probe (Mylab1, Esaote). Ultrasound measurements were consecutively performed: a) by an expert user in hand-held mode in standing as well as supine position, b) using the telerobotic arm without centrifugation as baseline and c) using the telerobotic arm during centrifugation. Vascular responses were compared between baseline and under centrifugation. Inter-, intra-registration and group variability have been assessed for hand-held and remotely controlled examination. The results show that intra-registration variability, σh , was always smaller than inter-registration variability, σm, that is in turned smaller than the inter-subject variability σg (σh < σm < σg). Centrifugation caused no significant changes in CCA diameter but a lower carotid distension compared to manual and robotic ultrasound in supine position (p < 0.05). Femoral diameter was significantly decreased in hypergravity compared to robotic sonography without centrifugation. A good reproducibility and precision of the remotely controlled vascular ultrasound assessment under centrifugation could be demonstrated. In conclusion, arterial wall dynamics can be precisely assessed for the CCA and femoral artery during centrifugation using a telerobotic ultrasound measurement system. Potential improvements to further enhance reproducibility and safety of the system are discussed.
引用
收藏
相关论文
共 50 条
  • [31] Development of Measurement System for Quantitative Evaluation of Skillfulness of Lower Extremities
    Yamazaki, Kazunori
    Jin, Dongjun
    Morita, Yoshifumi
    Sato, Noritaka
    Ukai, Hiroyuki
    Kozakai, Kenji
    Shibata, Satoru
    Onishi, Shigenori
    Ito, Akihiro
    Mizuno, Daisuke
    Hirai, Tatsuya
    Takeda, Haruna
    Sugiura, Yuka
    JOURNAL OF ROBOTICS NETWORKING AND ARTIFICIAL LIFE, 2014, 1 (02): : 116 - 119
  • [32] Development of Measurement System for Quantitative Evaluation of Skillfulness of Lower Extremities
    Yamazaki, Kazunori
    Kim, Donggun
    Morita, Yoshifumi
    Sato, Noritaka
    Ukai, Hiroyuki
    Kozakai, Kenji
    Shibata, Satoru
    Onishi, Shigenori
    Ito, Akihiro
    Mizuno, Daisuke
    Hirai, Tatsuya
    Takeda, Haruna
    Sugiura, Yuka
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2014), 2014, : 14 - 17
  • [33] DESIGN AND EXPERIMENTAL EVALUATION OF ARM INTRACAVITARY ULTRASOUND PHASED-ARRAY SYSTEM FOR HYPERTHERMIA
    BUCHANAN, MT
    HYNYNEN, K
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (12) : 1178 - 1187
  • [34] QUANTITATIVE EVALUATION OF FIBRINOLYTIC ENZYMES IN SIMULATED HUMAN SYSTEM
    MUNSON, AE
    LIPPSCHUTZ, E
    AMBRUS, CM
    AMBRUS, JL
    LASSMAN, H
    BACK, N
    JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (03) : 536 - &
  • [35] Dynamics of Brain Potentials in Volunteers for Modeled Head-to-Pelvis G-Loads (+Gz) on a Short-Arm Human Centrifuge
    Schastlivtseva D.V.
    Kotrovskaya T.I.
    Koloteva M.I.
    Glebova T.M.
    Human Physiology, 2023, 49 (7) : 819 - 824
  • [36] Evaluation of a Semi-Automated Ultrasound Guidance System for Central Vascular Access
    Hernandez Torres, Sofia I.
    Caldwell, Nicole W.
    Snider, Eric J.
    BIOENGINEERING-BASEL, 2024, 11 (12):
  • [37] Evaluation of a new calcaneal quantitative ultrasound system and determination of normative ultrasound values in southern Chinese women
    Kung, AWC
    Tang, GWK
    Luk, KDK
    Chu, LW
    OSTEOPOROSIS INTERNATIONAL, 1999, 9 (04) : 312 - 317
  • [38] Evaluation of a New Calcaneal Quantitative Ultrasound System and Determination of Normative Ultrasound Values in Southern Chinese Women
    A. W. C. Kung
    G. W. K. Tang
    K. D. K. Luk
    L. W. Chu
    Osteoporosis International, 1999, 9 : 312 - 317
  • [39] Quantitative evaluation of traffic measurement for IP-based control system
    Shimomura, Takanori
    Kubo, Kazuya
    Okabe, Nobuo
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 1682 - 1686
  • [40] The quantitative evaluation of anterior drawer test using an electromagnetic measurement system
    Kataoka, Kiminari
    Hoshino, Yuichi
    Nagamune, Kouki
    Nukuto, Koji
    Yamamoto, Tetsuya
    Yamashita, Takahiro
    Kanzaki, Noriyuki
    Kakutani, Kenichiro
    Matsushita, Takehiko
    Kuroda, Ryosuke
    SPORTS BIOMECHANICS, 2022, 21 (04) : 550 - 561