Combining prospective motion correction and distortion correction for EPI: towards a comprehensive correction of motion and susceptibility-induced artifacts

被引:0
|
作者
Rainer Boegle
Julian Maclaren
Maxim Zaitsev
机构
[1] University Hospital Freiburg,Department of Radiology Medical Physics
关键词
EPI distortion correction; Prospective motion correction; Susceptibility-induced artifacts; Magnetic susceptibility; Field inhomogeneity prediction;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:263 / 273
页数:10
相关论文
共 50 条
  • [31] Self-navigated prospective motion correction for 3D-EPI acquisition
    Bayih, Samuel Getaneh
    Jankiewicz, Marcin
    Alhamud, A.
    van der Kouwe, Andre J. W.
    Meintjes, Ernesta M.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) : 211 - 223
  • [32] Prospective motion correction for diffusion weighted EPI of the brain using an optical markerless tracker
    Berglund, Johan
    van Niekerk, Adam
    Ryden, Henric
    Sprenger, Tim
    Avventi, Enrico
    Norbeck, Ola
    Glimberg, Stefan L.
    Olesen, Oline V.
    Skare, Stefan
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1427 - 1440
  • [33] Simultaneous multislice EPI prospective motion correction by real-time receiver phase correction and coil sensitivity map interpolation
    Li, Bo
    Li, Ningzhi
    Wang, Ze
    Balan, Radu
    Ernst, Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 1932 - 1948
  • [34] Subpixel motion artifacts correction and motion estimation for 3D-OCT
    Zhang, Xiao
    Zhong, Haozhe
    Wang, Sainan
    He, Bin
    Cao, Liangqi
    Li, Ming
    Jiang, Miaowen
    Li, Qin
    JOURNAL OF BIOPHOTONICS, 2024, 17 (09)
  • [35] The effects of geometric distortion correction on motion realignment in fMRI
    Elliott, MA
    Gualtieri, EE
    Hulvershorn, J
    Ragland, JD
    Gur, R
    ACADEMIC RADIOLOGY, 2004, 11 (09) : 1005 - 1010
  • [36] Diffusion Imaging With Prospective Motion Correction and Reacquisition
    Benner, Thomas
    van der Kouwe, Andre J. W.
    Sorensen, A. Gregory
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 154 - 167
  • [37] Prospective motion correction using tracking coils
    Qin, Lei
    Schmidt, Ehud J.
    Tse, Zion Tsz Ho
    Santos, Juan
    Hoge, William S.
    Tempany-Afdhal, Clare
    Butts-Pauly, Kim
    Dumoulin, Charles L.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 749 - 759
  • [38] Navigator Accuracy Requirements for Prospective Motion Correction
    Maclaren, Julian
    Speck, Oliver
    Stucht, Daniel
    Schulze, Peter
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (01) : 162 - 170
  • [39] Prospective motion correction in brain imaging: A review
    Maclaren, Julian
    Herbst, Michael
    Speck, Oliver
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 621 - 636
  • [40] Quantitative Framework for Prospective Motion Correction Evaluation
    Pannetier, Nicolas A.
    Stavrinos, Theano
    Ng, Peter
    Herbst, Michael
    Zaitsev, Maxim
    Young, Karl
    Matson, Gerald
    Schuff, Norbert
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 810 - 816