Accuracy validation of sleep measurements by a contactless biomotion sensor on subjects with suspected sleep apnea

被引:0
|
作者
Masanori Hashizaki
Hiroshi Nakajima
Masakazu Tsutsumi
Toshikazu Shiga
Shintaro Chiba
Tomoko Yagi
Yuko Ojima
Azusa Ikegami
Minako Kawabata
Kazuhiko Kume
机构
[1] Omron Corporation,Technology and Intellectual Property H.Q.
[2] Omron Healthcare Co.,Kuwamizu Hospital
[3] LTD.,Institute of Molecular Embryology and Genetics
[4] Ota Memorial Sleep Center,Department of Neuropharmacology, Graduate School of Pharmaceutical Sciences
[5] Kumamoto University,undefined
[6] Kumamoto University,undefined
[7] Nagoya City University,undefined
来源
关键词
actigraphy; contactless; polysomnography; sensor; sleep;
D O I
暂无
中图分类号
学科分类号
摘要
Due to the busy lifestyles of people in developed countries, insufficient sleep has emerged as a central health issue in the general population. Objective home sleep monitoring is preferable for identifying sleep problems and improving sleep quality. Several instruments, most notably wrist actigraphy, have been used for this purpose. However, various impediments, including economic and practical concerns, have continued to hamper the widespread use of self-sleep monitoring. In this study, we used the contactless biomotion sensor based on SleepMinder™ with a frequency band modified from 5.8 GHz to 10.525 Hz to comply with Japanese Radio Law. The purpose of the study was to validate the accuracy of the sleep-wake algorithm for adult outpatients used by this new sensing system. We examined the data using simultaneous polysomnography and compared the results with previous contactless biomotion sensor and actigraphy studies. Data were collected at two institutions, the Ota Memorial Sleep Center and Kuwamizu Hospital. In total, 211 adult subjects participated in the study, and 148 (99 subjects with apnea-hypopnea index score 15) were used for the analysis. The overall accuracy of the new system was 84.1%, and its sensitivity and specificity were 91.8% and 37.6%, respectively. The automated algorithm slightly overestimated total sleep time (bias: +13 min) and sleep efficiency (bias: +3%) compared with polysomnography. As for sleep onset latency and wake time after sleep onset, these were slightly underestimated. The results are comparable to previous contactless biomotion sensor and actigraphy studies, and indicate that this modified contactless biomotion sensor is sufficiently accurate for monitoring sleep-wake patterns in this population.
引用
收藏
页码:106 / 115
页数:9
相关论文
共 50 条
  • [21] WRIST ACTIGRAPHIC ASSESSMENT OF SLEEP IN 116 COMMUNITY-BASED SUBJECTS SUSPECTED OF OBSTRUCTIVE SLEEP-APNEA SYNDROME
    MIDDELKOOP, HAM
    NEVEN, AK
    VANHILTEN, JJ
    RUWHOF, CW
    KAMPHUISEN, HAC
    THORAX, 1995, 50 (03) : 284 - 289
  • [22] Validation of Unobtrusive Pressure Sensor Array for Central Sleep Apnea Screening
    Townsend, Daphne
    Goubran, Rafik
    Knoefel, Frank
    Leech, Judith
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (07) : 1857 - 1865
  • [23] SEX DIFFERENCES IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA AND SUSPECTED HYPOVENTILATION ON HOME SLEEP APNEA TESTING
    Braganza, M.
    Tsai, W.
    Lee, M.
    Fraser, K.
    Hanly, P.
    Pendharkar, S.
    SLEEP MEDICINE, 2019, 64 : S297 - S298
  • [24] Accuracy of sleep questionnaires for obstructive sleep apnea syndrome screening
    Saldias Penafiel, Fernando
    Gassmann Poniachik, Javiera
    Canelo Lopez, Alejandro
    Uribe Monasterio, Javier
    Diaz Patino, Orlando
    REVISTA MEDICA DE CHILE, 2018, 146 (10) : 1123 - 1134
  • [25] Sleep measurement accuracy of smartwatch in patients with obstructive sleep apnea
    Park, Kunwoo
    Shin, Wonchul
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2023, 455
  • [26] Accuracy of the clinical parameters and oximetry to initiate CPAP in patients with suspected obstructive sleep apnea
    Carlos Alberto Nigro
    Eduardo Dibur
    Edgardo Rhodius
    Sleep and Breathing, 2012, 16 : 1073 - 1079
  • [27] Obstructive sleep apnea in overweight subjects
    Arias, MA
    Sánchez, AM
    Fernández-Guerrero, JC
    Alonso-Fernández, A
    García-Río, F
    HYPERTENSION, 2006, 47 (01) : E1 - E1
  • [28] Accuracy of the clinical parameters and oximetry to initiate CPAP in patients with suspected obstructive sleep apnea
    Nigro, Carlos Alberto
    Dibur, Eduardo
    Rhodius, Edgardo
    SLEEP AND BREATHING, 2012, 16 (04) : 1073 - 1079
  • [29] Validation of sleep-staging accuracy for an in-home sleep electroencephalography device compared with simultaneous polysomnography in patients with obstructive sleep apnea
    Seol, Jaehoon
    Chiba, Shigeru
    Kawana, Fusae
    Tsumoto, Saki
    Masaki, Minori
    Tominaga, Morie
    Amemiya, Takashi
    Tani, Akihiro
    Hiei, Tetsuro
    Yoshimine, Hiroyuki
    Kondo, Hideaki
    Yanagisawa, Masashi
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [30] Validation of sleep-staging accuracy for an in-home sleep electroencephalography device compared with simultaneous polysomnography in patients with obstructive sleep apnea
    Jaehoon Seol
    Shigeru Chiba
    Fusae Kawana
    Saki Tsumoto
    Minori Masaki
    Morie Tominaga
    Takashi Amemiya
    Akihiro Tani
    Tetsuro Hiei
    Hiroyuki Yoshimine
    Hideaki Kondo
    Masashi Yanagisawa
    Scientific Reports, 14