Detection of Coronary Artery Disease Using Automutual Information

被引:8
|
作者
Benjamin Griffel
Mohammad K. Zia
Vladimir Fridman
Cesare Saponieri
John L. Semmlow
机构
[1] Griffel, Benjamin
[2] Zia, Mohammad K.
[3] Fridman, Vladimir
[4] Saponieri, Cesare
[5] Semmlow, John L.
来源
Griffel, B. (griffebe@umdnj.edu) | 1600年 / Springer Science and Business Media, LLC卷 / 03期
关键词
Computer aided diagnosis - Diseases - Information use - Acoustic waves - Biomedical signal processing;
D O I
10.1007/s13239-012-0094-6
中图分类号
学科分类号
摘要
Coronary artery disease (CAD) is the leading cause of death in the United States, but there is no detection method that is suitable as an early screening tool. The exercise stress test can be performed noninvasively but requires physical exertion and has low accuracy. A nuclear stress test has higher accuracy, but requires the use of a radio-nucleotide that exposes the patient to radiation. Detection of CAD using acoustic signals recorded from the chest is inexpensive, uses no radiation and is noninvasive. Therefore, the acoustic method is an ideal early screening tool. CAD sounds (bruits) are produced by turbulent blood flow caused by partially obstructed arteries and turbulence is a nonlinear process. Therefore, this study evaluated a nonlinear signal analysis method, the automutual information function (AMIF(τ)), for detection of CAD bruits. The AMIF(τ) was applied to diastolic signals from 16 normal and 15 diseased subjects. Four parameters of the AMIF(τ) curve were evaluated: (1) lag∈ the lag when the value of the curve is 1/e; (2) the lag of the first AMIF(τ) peak; (3) the value of the first AMIF(τ) peak; and (4) the integral of the curve. Using the standard deviation (std) and mean value of AMIF(τ) parameters as features in a linear support vector machine classifier, the best individual AMIF(τ) parameter was lag∈ This classified normal and diseased subjects retrospectively with a sensitivity-specificity of 80-69%, with 74% accuracy. Using a combination of AMIF(τ) measurements further improved accuracy. The combination of std values for first peak lag and lag∈ gave a sensitivity-specificity of 87-75% with an 81% accuracy. Since the mutual information function is similar to the linear autocorrelation, the autocorrelation was also considered, using the same parameters to quantify the correlation function. The best combination of autocorrelation parameters, the first peak lag and mean of the sum of the autocorrelation function, gave an accuracy of 75%. The best individual autocorrelation measurement was the first peak lag, with a sensitivity-specificity of 67-75% and an accuracy of 71%. These results indicate AMIF(τ) is sensitive to signatures of CAD bruits and may be useful for acoustic detection of CAD. However, linear correlation analysis discriminated normal and diseased subjects nearly as well, indicating that the acoustic signals recorded contain mostly linear information. © 2012 Biomedical Engineering Society.
引用
收藏
页码:333 / 344
页数:11
相关论文
共 50 条
  • [21] Detection of the Lumen Boundary in the Coronary Artery Disease
    Sofian, Hannah
    Ming, Joel Than Chia
    Noor, Norliza Mohd
    2015 IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (WIECON-ECE), 2015, : 143 - 146
  • [22] DETECTION OF CORONARY-ARTERY DISEASE IN WOMEN
    PANCHOLY, S
    GIOIA, G
    RUSSELL, J
    CASSEL, D
    HEO, JY
    ISKANDRIAN, AS
    CIRCULATION, 1995, 92 (08) : 616 - 616
  • [23] Detection of Coronary Artery Disease with an Electronic Stethoscope
    Schmidt, S. E.
    Holst-Hansen, C.
    Graff, C.
    Toft, E.
    Struijk, J. J.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 757 - +
  • [24] DETECTION OF ASYMPTOMATIC CORONARY-ARTERY DISEASE
    FROELICHER, VF
    ANNUAL REVIEW OF MEDICINE, 1977, 28 : 1 - 12
  • [25] Coronary CT Angiography for the Detection of Obstructive Coronary Artery Disease
    Maurovich-Horvat P.
    Ghoshhajra B.
    Ferencik M.
    Current Cardiovascular Imaging Reports, 2010, 3 (6) : 355 - 365
  • [26] DETECTION OF CORONARY CALCIUM DEPOSITS AND CORONARY-ARTERY DISEASE
    PLAINFOSSE, MC
    PRESSE MEDICALE, 1994, 23 (18): : 845 - 847
  • [27] Entropies for automated detection of coronary artery disease using ECG signals: A review
    Acharya, Udyavara Rajendra
    Hagiwara, Yuki
    Koh, Joel En Wei
    Oh, Shu Lih
    Tan, Jen Hong
    Adam, Muhammad
    Tan, Ru San
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2018, 38 (02) : 373 - 384
  • [28] Coronary Artery Disease Detection Using a Fuzzy-Boosting PSO Approach
    Hedeshi, N. Ghadiri
    Abadeh, M. Saniee
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2014, 2014
  • [29] DETECTION OF CORONARY-ARTERY DISEASE USING MR IMAGING WITH DIPYRIDAMOLE INFUSION
    PENNELL, DJ
    UNDERWOOD, SR
    LONGMORE, DB
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (02) : 167 - 170
  • [30] Automated Echocardiographic Detection of Severe Coronary Artery Disease Using Artificial Intelligence
    Upton, Ross
    Mumith, Angela
    Beqiri, Arian
    Parker, Andrew
    Hawkes, William
    Gao, Shan
    Porumb, Mihaela
    Sarwar, Rizwan
    Marques, Patricia
    Markham, Deborah
    Kenworthy, Jake
    O'Driscoll, Jamie M.
    Hassanali, Neelam
    Groves, Kate
    Dockerill, Cameron
    Woodward, William
    Alsharqi, Maryam
    McCourt, Annabelle
    Wilkes, Edmund H.
    Heitner, Stephen B.
    Yadava, Mrinal
    Stojanovski, David
    Lamata, Pablo
    Woodward, Gary
    Leeson, Paul
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (05) : 715 - 727