A Post-Processing Method for Three-Dimensional Electrical Impedance Tomography

被引:0
|
作者
Sébastien Martin
Charles T. M. Choi
机构
[1] National Chiao Tung University,Department of Electrical and Computer Engineering
[2] National Chiao Tung University,Institute of Biomedical Engineering
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Electrical impedance tomography is a modern biomedical imaging method. Its goal is to image the electrical properties of human tissues. This approach is safe for the patient’s health, is non-invasive and has no known hazards. However, the approach suffers from low accuracy. Linear inverse solvers are commonly used in medical applications, as they are strongly robust to noise. However, linear methods can give only an approximation of the solution that corresponds to a linear perturbation from an initial estimate. This paper proposes a novel reconstruction process. After applying a linear solver, the conductivity distribution is post-processed with a nonlinear algorithm, with the aim of reproducing the abrupt change in conductivity at the boundaries between tissues or organs. The results are used to compare the proposed method with three other widely used methods. The proposed method offers higher quality images and a higher robustness to noise, and significantly reduces the error associated with image reconstruction.
引用
收藏
相关论文
共 50 条
  • [21] Three-dimensional morphological characteristics measurement of ankle joint based on computed tomography image post-processing
    Chen Yan-xi
    Lu Xiao-ling
    Bi Gang
    Yu Xiao
    Hao Yi-li
    Zhang Kun
    Zou Li-ling
    Mei Jiong
    Yu Guang-rong
    CHINESE MEDICAL JOURNAL, 2011, 124 (23) : 3912 - 3918
  • [22] An Improved Post-Processing Method for Three-Dimensional Visualization in Terahertz Pulse-Echo Imaging
    Hanaizumi, H.
    2018 43RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2018,
  • [23] A Statistical Post-Processing Method for Three-Dimensional Visualization for Terahertz Pulse-Echo Imaging
    Hanaizumi, H.
    Fukunaga, K.
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [24] Design of Three-Dimensional Electrical Impedance Tomography System for Rock Samples
    Peng, Xin
    Chun, Shaoheng
    Su, Benyu
    Chen, Rujun
    Hou, Shenglan
    Xu, Chao
    Zhang, Haojie
    APPLIED SCIENCES-BASEL, 2024, 14 (04):
  • [25] Three-dimensional nonstationary electrical impedance tomography with a single electrode layer
    Voutilainen, A.
    Lehikoinen, A.
    Vauhkonen, M.
    Kaipio, J. P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (03)
  • [26] Three-dimensional electrical impedance tomography based on the complete electrode model
    Vauhkonen, PJ
    Vauhkonen, M
    Savolainen, T
    Kaipio, JP
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (09) : 1150 - 1160
  • [27] Compressed sampling for boundary measurements in three-dimensional electrical impedance tomography
    Javaherian, Ashkan
    Soleimani, Manuchehr
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (09) : 1133 - 1149
  • [28] Truncated-Newton algorithm for three-dimensional electrical impedance tomography
    Player, MA
    van Weereld, J
    Allen, AR
    Collie, DAL
    ELECTRONICS LETTERS, 1999, 35 (25) : 2189 - 2191
  • [29] Three-dimensional electrical impedance tomography using complete electrode model
    Vauhkonen, M
    Vauhkonen, PJ
    Kaipio, JP
    Karjalainen, PA
    COMPUTATIONAL, EXPERIMENTAL, AND NUMERICAL METHODS FOR SOLVING ILL-POSED INVERSE IMAGING PROBLEMS: MEDICAL AND NONMEDICAL APPLICATIONS, 1997, 3171 : 166 - 174
  • [30] Anatomically constrained electrical impedance tomography for three-dimensional anisotropic bodies
    Glidewell, ME
    Ng, KT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) : 572 - 580