The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar’s test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.
引用
收藏
页码:86 / 92
页数:6
相关论文
共 50 条
  • [31] Left inferior vena cava with regressed right inferior vena cava
    Honma S.
    Tokiyoshi A.
    Kawai K.
    Koizumi M.
    Kodama K.
    Anatomical Science International, 2008, 83 (3) : 173 - 178
  • [32] Endovascular Retrieval of Inferior Vena Cava Filter Penetrating Duodenum
    Shafique, Shoaib
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (04) : 1114 - 1115
  • [33] Costs and complications of endovascular inferior vena cava filter retrieval
    Brahmandam, Anand
    Skrip, Laura
    Mojibian, Hamid
    Aruny, John
    Sumpio, Bauer
    Dardik, Alan
    Sarac, Timur
    Chaar, Cassius Iyad Ochoa
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2019, 7 (05) : 653 - +
  • [34] Factors Affecting Inferior Vena Cava Filter Retrieval: A Review
    Crumley, Kristen D.
    Hyatt, Eddie
    Kalva, Sanjeeva P.
    Shah, Hriday
    VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (03) : 224 - 229
  • [35] Assessing the rate of inferior vena cava filter use and retrieval
    Osinbowale, Olusegun
    Ahsan, Syed
    VASCULAR MEDICINE, 2014, 19 (03) : 232 - 232
  • [36] Successful retrieval of a Ionglasting temporary inferior vena cava filter
    Couturier, M.
    Annweiler, T.
    Bertoletti, L.
    Barral, F. -G.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 481 - 482
  • [37] Cardiac tamponade: A complication of inferior vena cava filter retrieval
    Liang, Jackson J.
    Mankad, Sunil V.
    Johnson, C. Michael
    Cooper, Leslie T.
    VASCULAR MEDICINE, 2014, 19 (03) : 241 - 242
  • [38] Complex Hybrid Suprarenal Inferior Vena Cava Filter Retrieval
    Chou, Elizabeth L.
    Sgroi, Michael D.
    Fujitani, Roy M.
    Kabutey, Nii-Kabu
    ANNALS OF VASCULAR SURGERY, 2015, 29 (01)
  • [39] Percutaneous Retrieval of an Inferior Vena Cava Filter Penetrating Into the Duodenum
    Gibo, Hiroyuki
    Saito, Shota
    Koya, Jiro
    Yasui, Yutaro
    Tokuda, Yusuke
    Sugitatsu, Kazuya
    Makita, Yasuhiro
    Suzuki, Kazuharu
    Miyamoto, Shuichi
    Shoda, Morio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (12) : E131 - E133
  • [40] Is a Venacavogram Necessary after Inferior Vena Cava Filter Retrieval?
    Mintz, Joseph D.
    Stavropoulos, S. William
    Trerotola, Scott O.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (12) : 1857 - 1864