Voltammetric determination of hydroquinone on a mechanically renewed graphite-epoxy electrode in developing photographic solutions

被引:0
|
作者
O. V. Karunina
L. I. Skvortsova
机构
[1] Russian Academy of Sciences,Institute of Solid
来源
关键词
Hydroquinone; Reduction Peak; Anodic Peak; Cathodic Peak; Voltammetric Determination;
D O I
暂无
中图分类号
学科分类号
摘要
Effect of various components of developing photographic solutions on parameters of electro-oxidation-reduction peaks of hydroquinone in neutral and acid supporting solutions on a graphite-epoxy composite electrode with surface mechanically renewed directly in solution prior to each polarization cycle was studied. A procedure is suggested for voltammetric determination of the content of hydroquinone from the cathodic peak in a freshly prepared developing photographic solution and from the anodic peak in a solution allowed to stay upon preparation for 1 day and more.
引用
收藏
页码:1220 / 1224
页数:4
相关论文
共 50 条
  • [31] Sensor development exploiting graphite-epoxy composite as electrode material
    Azevedo, Andre L. M.
    Oliveira, Renato S.
    Ponzio, Eduardo A.
    Semaan, Felipe S.
    BRAZIL MRS MEETING 2014, 2015, 97
  • [33] Simultaneous determination of 4-chlorophenol and oxalic acid using an expanded graphite-epoxy composite electrode
    Manea, Florica
    Radovan, Ciprian
    Corb, Ioana
    Pop, Aniela
    Burtica, Georgeta
    Malchev, Plamen
    Picken, Stephen
    Schoonman, Joop
    ELECTROANALYSIS, 2008, 20 (15) : 1719 - 1722
  • [34] VOLTAMMETRIC STUDIES AT THE GRAPHITE ELECTRODE IN QUIET SOLUTIONS
    MORRIS, JB
    SCHEMPF, JM
    ANALYTICAL CHEMISTRY, 1959, 31 (02) : 286 - 291
  • [35] Thermoelastic determination of KI and KII in an orthotropic graphite-epoxy composite
    Ju, SH
    Rowlands, RE
    JOURNAL OF COMPOSITE MATERIALS, 2003, 37 (22) : 2011 - 2025
  • [36] VOLTAMMETRIC DETERMINATION OF PHARMACEUTICALS AT THE TUBULAR GRAPHITE ELECTRODE
    SHARMA, LR
    BANSAL, PC
    KALIA, RK
    MANCHANDA, AK
    ANALYST, 1980, 105 (1253) : 779 - 786
  • [37] Study of the pH function of a mechanically renewed graphite-quinhydrone indicator electrode
    Skvortsova, L. I.
    Karunina, O. V.
    Bek, R. Yu.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (08) : 854 - 860
  • [38] Study of the pH function of a mechanically renewed graphite-quinhydrone indicator electrode
    L. I. Skvortsova
    O. V. Karunina
    R. Yu. Bek
    Journal of Analytical Chemistry, 2010, 65 : 854 - 860
  • [39] A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
    Ocana, Cristina
    Pacios, Merce
    del Valle, Manel
    SENSORS, 2012, 12 (03): : 3037 - 3048
  • [40] Electrochemical Behavior of the System Ferricyanide-Ferrocyanide at a Graphite-Epoxy Composite Electrode
    Kiryushov, V. N.
    Skvortsova, L. I.
    Aleksandrova, T. P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (05) : 510 - 514