Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI

被引:28
|
作者
Gunzinger J.M. [1 ]
Delso G. [2 ]
Boss A. [3 ]
Porto M. [1 ]
Davison H. [1 ]
von Schulthess G.K. [1 ]
Huellner M. [1 ,4 ]
Stolzmann P. [1 ,4 ]
Veit-Haibach P. [1 ,3 ]
Burger I.A. [1 ,3 ]
机构
[1] Department of Medical Radiology, Division of Nuclear Medicine, University Hospital Zurich, Ramistr. 100, Zurich
[2] Global MR Applications and Workflow, GE Healthcare, Zurich
[3] Department of Medical Radiology, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistr. 100, Zurich
[4] Department of Medical Radiology, Institute of Neuroradiology, University Hospital Zurich, Ramistr. 100, Zurich
关键词
Attenuation correction; Image noise; MAVRIC; Signal voids;
D O I
10.1186/s40658-014-0102-z
中图分类号
学科分类号
摘要
Background: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acquisition variable-resonance image combination (MAVRIC SL) in comparison to conventional high-bandwidth techniques and in a second step showed the effect of artifact size on MRI-based attenuation correction (AC) with a simulation study. Methods: Twenty-five patients with dental implants prospectively underwent a trimodality PET/CT/MRI examination after informed consent was obtained under the approval of the local ethics committee. A conventional 3D gradient-echo sequence (LAVA-Flex) commonly used for MRI-based AC of PET (acquisition time of 14 s), a T1w fast spin-echo sequence with high bandwidth (acquisition time of 3.2 min), as well as MAVRIC SL sequence without and with increased phase acceleration (MAVRIC, acquisition time of 6 min; MAVRIC-fast, acquisition time of 3.5 min) were applied. The absolute and relative reduction of the signal void artifact was calculated for each implant and tested for statistical significance using the Wilcoxon signed-rank test. The effect of artifact size on PET AC was simulated in one case with a large tumor in the oral cavity. The relative difference of the maximum standardized uptake value (SUVmax) in the tumor was calculated for increasing artifact sizes centered over the second molar. Results: The absolute reduction of signal void from LAVA-Flex sequences to the T1-weighted fast spin-echo (FSE) sequences was 416 mm2 (range 4 to 2,010 mm2) to MAVRIC 481 mm2 (range 12 to 2,288 mm2) and to MAVRIC-fast 486 mm2 (range 39 to 2,209 mm2). The relative reduction in signal void was significantly improved for both MAVRIC and MAVRIC-fast compared to T1 FSE (−75%/− 78% vs. − 62%, p < 0.001 for both). The relative error for SUVmax was negligible for artifacts of 0.5-cm diameter (−0.1%), but substantial for artifacts of 5.2-cm diameter (−33%). Conclusions: MAVRIC-fast could become useful for artifact reduction in PET/MR for patients with dental implants. This might improve diagnostic accuracy especially for patients with tumors in the oropharynx and substantially improve accuracy of PET quantification. © 2014, Gunzinger et al; licensee Springer.
引用
收藏
页码:1 / 14
页数:13
相关论文
共 50 条
  • [21] Optical impression method to measure three-dimensional position and orientation of dental implants using an optical tracker
    Ono, Shinji
    Yamaguchi, Satoshi
    Kusumoto, Naoki
    Nakano, Tamaki
    Sohmura, Taiji
    Yatani, Hirofumi
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (10) : 1117 - 1122
  • [22] Metal artifact reduction in CT-based attenuation correction of PET data using the virtual sinogram concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009, 2009,
  • [23] Metal Artifact Reduction in CT-Based Attenuation Correction of PET Data Using the Virtual Sinogram Concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1848 - +
  • [24] Production of inter-connective porous dental implants by computer-aided design and metal three-dimensional printing
    Chen, Jianyu
    Zhang Xiao
    Sun Yangpeng
    Deng, Feilong
    Zhang Zhiguang
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2020, 34 (09) : 1227 - 1238
  • [25] Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition
    Shin, Taehoon
    Nayak, Krishna S.
    Santos, Juan M.
    Nishimura, Dwight G.
    Hu, Bob S.
    McConnell, Michael V.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 839 - 844
  • [26] Development of a Three-Dimensional Slurry Printing System Using Dynamic Mask Projection for Fabricating Zirconia Dental Implants
    Lee, Shyh-Yuan
    Jiang, Cho-Pei
    MATERIALS AND MANUFACTURING PROCESSES, 2015, 30 (12) : 1498 - 1504
  • [27] Reduction of three-dimensional metal oxides for hydrogen regeneration using ultraviolet laser irradiation
    Seo, Keumyoung
    Lim, Taekyung
    Jeong, Sang-Mi
    Ju, Sanghyun
    MATERIALS RESEARCH EXPRESS, 2019, 6 (06)
  • [28] Rapid Three-Dimensional Printing in Water Using Semiconductor Metal Hybrid Nanoparticles as Photoinitiators
    Pawar, Amol Ashok
    Halivni, Shira
    Waiskopf, Nir
    Ben-Shahar, Yuval
    Soreni-Harari, Michal
    Bergbreiter, Sarah
    Banin, Uri
    Magdassi, Shlomo
    NANO LETTERS, 2017, 17 (07) : 4497 - 4501
  • [29] The demonstration of gyral abnormalities in patients with cryptogenic partial epilepsy using three-dimensional MRI
    Sisodiya, SM
    Stevens, JM
    Fish, DR
    Free, SL
    Shorvon, SD
    ARCHIVES OF NEUROLOGY, 1996, 53 (01) : 28 - 34
  • [30] Data extraction from brain PET images using three-dimensional stereotactic surface projections
    Minoshima, S
    Ficaro, EP
    Frey, KA
    Koeppe, RA
    Kuhl, DE
    QUANTITATIVE FUNCTIONAL BRAIN IMAGING WITH POSITRON EMISSION TOMOGRAPHY, 1998, : 133 - 137