Modeling of an ionized electric field on the building near the UHVDC transmission line

被引:0
|
作者
YongZan Zhen
Xiang Cui
TieBing Lu
机构
[1] North China Electric Power University,State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources
[2] North China Electric Power University,Post
来源
关键词
building; finite element method (fem); human body; hvdc; ionized electric field;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, a 3D upstream finite element method is developed to analyze the ionized electric field around the UHVDC transmission lines including the building near it. The ionized electric field around the building is reduced due to the shielding effect of the building and the shielding distance is about three times its height. The ionized electric field including the human body model on the building and away from the building is also taken into account. The ionized electric field distortion ratio of the human body model is discussed in this paper. The distortion ratios for the positions on the building are less than those on the ground.
引用
收藏
页码:747 / 753
页数:6
相关论文
共 50 条
  • [31] Electric field disturbance caused by an unmanned aerial vehicle flying near the HV power transmission line
    Liu, Shemin
    Sheng, Congbing
    Meng, Fanzhong
    Wang, Shengdan
    Wang, Rui
    Zhang, Yabo
    Zhu, Yunfeng
    Xu, Zheng
    He, Wei
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [32] Electric Field Calculation of High Voltage Transmission Line
    Lu, Yong
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 624 - 627
  • [33] Simulation of the Electric Field on the Surface of the Sub-conductor of ±1100kV UHVDC Transmission Lines
    Lu, Haoyu
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 1970 - 1973
  • [34] Highly Stable Upwind FEM for Solving Ionized Field of HVDC Transmission Line
    Huang, Guodong
    Ruan, Jiangjun
    Du, Zhiye
    Zhao, Changwei
    IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (02) : 719 - 722
  • [35] Simulation Study on Transient Response of UHVDC Transmission Line Fault
    Chen, Shilong
    Xie, Jiawei
    Zhang, Jie
    Liu, Li
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 2266 - 2271
  • [36] Transmission Line Model of Field-to-Wire Coupling with Transmission Line Cables From Near and Far Field Sources
    Li, Jingxiao
    Gassab, Oussama
    He, Fang
    Su, Zhizhen
    Liao, Jie
    Zhan, Qiwei
    Yin, Wen-Yan
    PROCEEDINGS OF THE 2021 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC 2021), 2021,
  • [37] Pollution external insulation design and arrangement of UHVDC transmission line
    Wuhan High Voltage Research Institute of SGCC, Wuhan 430074, China
    不详
    Gaodianya Jishu, 2008, 5 (862-866):
  • [38] MV line electric field evaluation near a concrete pole
    Desideri, D
    Guarnieri, M
    Poli, E
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (02) : 718 - 721
  • [39] Effects of Transmission Line Faults on Electric Field Distribution Nearby
    Huang X.
    Ma Y.
    Zhu Y.
    Cao W.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2021, 55 (04): : 126 - 134
  • [40] Electric Field Distribution and their Impact on Transmission Line Composite Insulators
    Phillips, Andrew
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,